3nh Spectrophotometer YS3060 SCE SCI D/8 Hunter lab Color Test Reader Meter with 8mm and 4mm apertures
3nh Spectrophotometer YS3060 SCE SCI D/8 Hunter lab Color Test Reader Meter with 8mm and 4mm apertures is our most advanced handheld spectrophotometer with high performance and sophisticated functions.
The d/8° integrating sphere design conforms to CIE/ISO/ASTM/DIN standards and is suitable for color quality evaluation and color matching with close tolerance.
3nh Spectrophotometer YS3060 SCE SCI D/8 Hunter lab Color Test Reader Meter with 8mm and 4mm apertures uses a concave grating and 256 element CMOS sensor with a LED+UV illumination to deliver high accuracy.
With its broad capabilities, 3nh Spectrophotometer YS3060 SCE SCI D/8 Hunter lab Color Test Reader Meter with 8mm and 4mm apertures is used in plastics, coatings, textiles and many other industries.
Model | YS3060 spectrophotometer |
---|---|
Illumination/observation system | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) |
Integrating sphere Size | Φ58mm |
Light Source | Combined LED Light, UV Light |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength range | 400~700nm |
Wavelength pitch | 10nm |
Reflectance range | 0~200% |
Measuring Aperture | Dual Aperture: 10mm/8mm & 5mm/4mm |
Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB |
Color difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter) |
Other Chromaticity Data | WI(ASTM E313, CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313),TI(ASTM E313, CIE/ISO), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness |
Observer | 2°/10° |
Illuminant | D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Display Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measurement Time | 1.5s |
Repeatability | Spectral Reflectance: standard deviation within 0.1%(400~700nm: within 0.2%) Colorimetric Value: Standard deviation within DeltaE*ab 0.04 (Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.) |
Inter Instrument Agreement | Within DeltaE*ab 0.2 (Average for 12 BCRA Series II color tiles) |
Dimension | L*W*H=184*77*105mm |
Weight | 600g |
Battery | Li-ion battery. 5000 times within 8 hours. |
Lamp Life | 5 years, more than 1.6 million measurements |
Display Screen | TFT 3.5inch, Capacitive Touch Screen |
Interface | USB/RS-232 |
Data Memory | Standard 2000 Pcs, Sample 20000 Pcs |
Operating Temperature | 0~40℃(32~104°F) |
Storage temperature | -20~50℃(-4~122°F) |
Standard Accessory | Power Adapter, Built-In Li-ion Battery, User Guide, PC Software, White and Black Calibration Cavity, Dust Cover |
Optional Accessory | Micro Printer, Powder Test Box |
Notes | The specifications are subject to change without notice. |