3nh portable color meter 8mm aperture NH300 colorimeter fruit juices with UTC accessory
Features
1. Leading Humanity Design and Convenient Operation
* Auto White and Black Calibration at Startup
* Structure Design in line with Ergonomics
* Easy-to-use Operation Interface
2. Stable Measurement Performance
* The average fluctuation of △E is less than 0.07, actually more in 0.03~0.06.
* Portable structure design which is more conductive to keeping the instrument stable when using.
3. Convenient and Fast Locating
* Illumination locating is a fast, simple and convenient locating function which is the original function by 3nh.
4. PC Software—Realize More Function Expansion
* 3nh has the intellectual property of PC software. The corresponding software serial number and
* password protection are configured in 3nh colorimeter.
* Be able to perform color difference analysis, color difference cumulative analysis, chromaticity index, color sample database management, simulating object color, etc.
5. Advanced Power Management Design
* 3nh is the first enterprise using high capacity Li-ion battery in colorimeter.
* 3nh Li-ion battery can be repeatedly charged which will save cost. Meanwhile, it can measure more than
* 3000 times on one charge to ensure the stability of long time measurement.
Specifications
NH300 | |
Illuminating/Viewing Geometry | 8/d |
Measuring Aperture | Φ8mm |
Detector | Silicon photoelectric diode |
Color Space | CIEL*a*b*C*h* CIEL*a*b* |
Color Difference Formula | E*ab L*a*b E*C*h |
Light Source | D65 |
Light Source Device | LED blue light excitation |
Errors Between Each Equipment | ≤0.40E*ab |
Storage | 100pcs standards 20000pcs samples |
Repeatability | Standard deviation within ΔE*ab 0.07 Average of 30 measurements of standard white plate |
Weight | 500g |
Dimension | 205×70×100 mm |
Power source | Rechargeable lithium-ion battery 3.7V@3200mAh |
Lamp Life | 5 years, more than 1.6 million measurements |
Charging Time | 2 hours (first time 8 hours--100% electricity) |
Measurement Times Before Recharging | More than 3000 times |
Operating Temperature/Humidity Range | -10~40℃, relative humidity 0~85% with no condensation |
Data Interface | USB |
Extended Aperture (optional) | - |
Printer (optional) | Miniature thermal printer |
NH300 spectra precision colorimeter for paper,ink, printing industry
Cerifications:
FAQ:
1. When I received NH310/NH300 colorimeter and perform measurement, why the measured data is abnormal?
After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.
2. In which condition, manual white and black calibration and auto calibration are required for NH310?
a. It’s needed to perform manual calibration for NH310 when first starting.
b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.
3. In which condition, manual white and black calibration for NH300 is required?
a. It’s needed to perform manual calibration for NH300 when first starting.
b. In the subsequent starting, no need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.
4. How to replace NH310 measuring aperture?
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select “Settings-Aperture Setting” in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display “White and Black Calibration” interface. White and black calibration must be performed.
e. Replace completed.
5. CQCS3 (Color Quality Control System) Installation
a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.
b. Double-click the setup.exe to install CQCS3 software.
c. Then double-click Install.bat under the CQCS3USB_Driver file to install the driver.
d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.
Warranty:
NH300 spectra precision colorimeter for paper,ink, printing industry is under warranty for 12 months from the purchase date. Customers must provide warranty card and valid proof of purchase.
Size | 45*23*38mm |
Gross weight | 4kg |
Standard accessory | Power Adapter, USB Cable, User Manual, CD (Including QC Software), Calibration Plate |
Optional accessory | micro printer,powder test box, universal test components, |