Specifications
Brand Name :
Eltek
Model Number :
241122.235
Place of Origin :
China
Certification :
CE, RoHS
MOQ :
1 set
Price :
negotiable
Packaging Details :
carton box
Delivery Time :
within 10 days of payment
Payment Terms :
L/C, T/T
Supply Ability :
1000 sets/month
Model :
241122.235
Part number :
241122.235
Efficiency :
> 95 %
Current (max cont. :
27.8 A (@VOUT < 36 VDC)
MTBF :
>2 700 000 (@ Tambient : 25 °C)
Ripple :
< 150 mVPP , 30 MHz bandwidth
Description

241122.235 36/1000 HE UI Eltek Flatpack S Rectifier Doc 241122.235.DS3 - v1

Description

Compact and reliable rectifier for rail and power utilities applications

Applications in these markets demand state of the art, reliable and safe DC power systems. Flatpack S delivers an industry leading power density in its segment, many safety functions, wide operating temperature range and superb reliability in its small 217mm deep housing.

Used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.

Features

Small

Short

Power Dense, 26 w / Cu In

High Efficiency

ORing Protection On Output

Wide Ac And Dc Input Range

Hot Plug-Able

Voltage Keying

Rail EMC Certification

Global Compliance (Ce, Ul)

Specifications

Model 36/1000 HE UI
Part number 241122.235
INPUT DATA
Voltage (nominal) 185 - 400 VDC / 185 - 275 VAC
Voltage (operating range) 85 - 400 VDC / 85 - 305 VAC
Frequency DC, 16 2/3 Hz, 45 - 66 Hz
Current (maximum) 5.9 ADC / 5.9 ARMS
Protection Fuse in Positive & Negative, Reversed polarity insensitive, Shutdown above 420 VDC / 305 VAC
OUTPUT DATA
Voltage 40 VDC
Voltage (adjustable range) 331) - 45 VDC
Power (maximum) @ nominal input 1000 W / 450 W @16 2/3 Hz input
Power (maximum) @ 85 VDC / 85 VAC input 440 W / 440 W
Current (max cont.) @ nominal input 27.8 A (@VOUT < 36 VDC)
Hold up time, maximum output power >10ms; output voltage > 33 VDC
Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load
Static Voltage regulation (10 - 100% load) ±0.5%
Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Ripple < 150 mVPP , 30 MHz bandwidth

Protection

ORing FET Short circuit proof

High temperature protection Over voltage Shutdown

OTHER SPECIFICATIONS
Efficiency > 95 %

Isolation

4.2 kVDC - input to output

2.25 kVDC - input to earth 710 VDC - output to earth

Alarms: Red LED Low and high input voltage, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure when fan stops, Low output voltage alarm, CAN bus failure
Warnings: Yellow LED Rectifier in power de-rate mode, Remote output current limit activated, Input voltage out of range, flashing at overvoltage, Loss of CAN communication with controller
Normal operation: Green LED
Alarm relay (NO - opens when de-energized) Opens on Alarms and missing input voltage.
MTBF (Telcordia Issue 3 & Method II Case L1) >2 700 000 (@ Tambient : 25 °C)
Operating temperature (5-95% RH n.cond. hum.) Maximum output power de-rates above temp / to -40 to + 85°C [-40 to +185°F] 45°C [140°F] / 400W @ 85°C [185°F]
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 72 x 40 x 217mm2) (2.84 x 1.57 x 8.54”)2) / < 850 g (1.9 lbs)
DESIGN STANDARDS
Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011

EMC

EN 61000-6-1:2007, -6-2:2005, - 6-3:2007 + A1:2010, - 6-4:2007 + A1:2010

EN 50121-1:2015, -2:2015, -4:2015, -5:2015

Environment

ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2)

RoHS (2011/65/EU) and WEEE (2012/19/EU) compliant

limited standby operation / needs some load to get to min set voltage

including handle depth is 234mm [9.21"] and height 42mm [1.65"]

Application

RAIL AND METRO

·FST-modem (Fail Safe Transmission)

·Line block systems

·Track circuits

·Signalling relays

POWER UTILITIES

Secondary Substations

241122.235 36/1000 HE UI Eltek Flatpack S Rectifier Doc 241122.235.DS3 - V1

Smartpack S Panel mount system controller

241122.235 36/1000 HE UI Eltek Flatpack S Rectifier Doc 241122.235.DS3 - V1

1U 3kW bulk feed power shelf

241122.235 36/1000 HE UI Eltek Flatpack S Rectifier Doc 241122.235.DS3 - V1

2U 3kW power core with 2-pole distribution

241122.235 36/1000 HE UI Eltek Flatpack S Rectifier Doc 241122.235.DS3 - V1

Flatpack S 2-pos standalone shelf

241122.235 36/1000 HE UI Eltek Flatpack S Rectifier Doc 241122.235.DS3 - V1

Flatpack S 3U system

Send your message to this supplier
Send Now

241122.235 36/1000 HE UI Eltek Flatpack S Rectifier Doc 241122.235.DS3 - V1

Ask Latest Price
Brand Name :
Eltek
Model Number :
241122.235
Place of Origin :
China
Certification :
CE, RoHS
MOQ :
1 set
Price :
negotiable
Contact Supplier
241122.235 36/1000 HE UI Eltek Flatpack S Rectifier Doc 241122.235.DS3 - V1

Wuhan Unique Mechanical And Electrical Equipment Co.,LTD.

Site Member
6 Years
hubei, wuhan
Since 2017
Business Type :
Manufacturer, Exporter
Total Annual :
3000000-5000000
Employee Number :
100~150
Certification Level :
Site Member
Contact Supplier
Submit Requirement