Specifications
Brand Name :
Eltek
Model Number :
241115.705
Place of Origin :
China
Certification :
CE, RoHS
MOQ :
1 set
Price :
negotiable
Packaging Details :
carton box
Delivery Time :
within 10 days of payment
Payment Terms :
L/C, T/T
Supply Ability :
1000 sets/month
Model :
48-60/2000 HE
Part number :
241115.705
Power @ 85 VAC :
750 W
THD :
< 5% at 100% load
Weight :
1.950 kg (4.3lbs)
Storage temp :
-40 to +85°C
Dimensions :
109 x 41.5 x 327mm
Power Factor :
> 0.99 at 50% load or more
Description

Eltek Flatpack2 Rectifier 48-60/2000 HE Doc 241115.705.DS3 - v9

High efficiency and reliable rectifier/converter

The most efficient power conversion module in the industry! Since the launch the Flatpack 2 family has expanded into a wide selection of power ratings and voltages.

The Flatpack2 48-60/2000 HE is a cost efficient rectifier for 48V and 60V lead acid battery systems as well as 48V NiCad.

Applications

TELECOM

Radio base stations / Cell sites

LTE / 4G / WIMAX

Distributed Antenna Systems

Microwave / Broadband

Central office

POWER UTILITIES

Control & protection

SCADA

Communications equipment

RAIL & METRO

Control & protection

Signaling

MARINE & OFFSHORE

Communications on ships

Key Features

High Efficiency – 96.2 %

Proven Reliability

High Power Density

Application Flexibility, 2kW To Multicabinet Installations

Modular Design

Mttr < 5mins

Accepts DC Input (DC/DC Converter)

Global Compliance (CE, Ul, NEBS)

Marine & Offshore Certifications

Patented Technology

Specifications

Model 48-60/2000 HE
Part number 241115.705
INPUT DATA
Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC
Voltage (operating range) 85 - 300 VAC / 80 - 300 VDC
Current (maximum) @ nominal input, full load 11.6 ARMS
Frequency 45 - 66 Hz / 0 Hz
Power Factor > 0.99 at 50% load or more
THD < 5% at 100% load
Protection Fuse in L & N, Varistor, Shutdown when input voltage is out of operating range
OUTPUT DATA
Voltage (default) 1) 53.5 VDC (67 VDC in 60V mode)
Voltage (adjustable range) 1) 39.9 - 72 VDC
Power (maximum) @ nominal input 2000 W (@VOUT ≥ 48VDC)
Power @ 85 VAC 750 W
Current (maximum) @ nominal input 41.6 A (@VOUT < 48VDC)
Hold up time, 1500W output power >20ms; output voltage > 53.5 VDC (60V mode)
Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load
Static Voltage regulation (10 - 100% load) ±0.5%
Dynamic Voltage regulation ±5.0% for 10-80% or 80-10% load variation, regulation time < 50ms
Ripple & noise < 150 mVPP , 30 MHz bandwidth / < 2 mVRMS psophometric
Protection Fuse , Short circuit proof, High temperature protection, Over voltage Shutdown
OTHER SPECIFICATIONS
Efficiency 96.2 %
Isolation 3.0 kVAC - input to output, 1.5 kVAC - input to earth, 500 VDC - output to earth
Low / high input voltage shutdown, High / low temperature shutdown, Rectifier
Alarms: Red LED

Failure, Overvoltage shutdown on output, Fan failure, Low output voltage

alarm, CAN bus failure

Rectifier in power de-rate mode, Remote output current limit activated, Input

Warnings: Yellow LED voltage out of range, flashing at overvoltage, Loss of CAN communication with controller
Normal operation: Green LED
MTBF (Telcordia SR-332 Iss.I method III (a)) >350 000 (@ Tambient : 25 °C)
Operating temp. (5-95% RH n.cond. hum.) -40 to + 75°C [-40 to +167°F]
Max output power de-rates above temp / to 45°C [113°F] / 1200W @ 75°C[167°F]
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13”) / 1.950 kg (4.3lbs)
DESIGN STANDARDS
Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013 UL 60950-1:2011
EMC

EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2011, -6-4:2007 + A1:2011,

IEC 61000-6-5: 2015, ETSI EN 300 386:2.1.1

Marine DNVGL-CG-03392)
Environment

ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)

2011/65/EU (RoHS) & 2012/19/EU (WEEE)

Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other

operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised

OVS setting from controller select mode: OVS≤59.5V = 48V mode (42-58V), 59.5V<OVS<70.85 = 48V NiCad mode (39.9-66V) and OVS≥70.85V = 60V mode (52.5-72V). W hen de-energized module will return to 48V mode.

Only valid for part number 241115.705M

Eltek Flatpack2 Rectifier 48-60/2000 HE 5G Network Equipment Doc 241115.705.DS3 - V9

16kW Telecom system in outdoor cabinet

Eltek Flatpack2 Rectifier 48-60/2000 HE 5G Network Equipment Doc 241115.705.DS3 - V9

2U 8kW bulk feed power system

Eltek Flatpack2 Rectifier 48-60/2000 HE 5G Network Equipment Doc 241115.705.DS3 - V9

1U 8kW power shelf

Send your message to this supplier
Send Now

Eltek Flatpack2 Rectifier 48-60/2000 HE 5G Network Equipment Doc 241115.705.DS3 - V9

Ask Latest Price
Brand Name :
Eltek
Model Number :
241115.705
Place of Origin :
China
Certification :
CE, RoHS
MOQ :
1 set
Price :
negotiable
Contact Supplier
Eltek Flatpack2 Rectifier 48-60/2000 HE 5G Network Equipment Doc 241115.705.DS3 - V9

Wuhan Unique Mechanical And Electrical Equipment Co.,LTD.

Site Member
6 Years
hubei, wuhan
Since 2017
Business Type :
Manufacturer, Exporter
Total Annual :
3000000-5000000
Employee Number :
100~150
Certification Level :
Site Member
Contact Supplier
Submit Requirement