ALR121-S50 YOKOGAWA Serial Communication Modules 4-wire System Multipoint SCS Modbus Communication
Description:
By using the SCS’s Modbus slave communication function, the data in SCS can be set or referred to by the Modbus master which is as separate system from SCS via a serial communication module. Furthermore, the subsystem data such as from sequencers can be set or referred to via a serial communication module using SCS’s subsystem communication function.
The dual-redundant configuration of the network can be available by establishing an independent transmission path from the Modbus master for every two the serial communication modules mounted in the SCS.
However, control/ stand-by switching function in between the dual-redundant serial communication modules mounted on adjacent slots is not supported.
Communication module’s definition information, Modbus device addresses, mapping definition of SCS data, and so on are to be downloaded using engineering function of a Safety Engineering Station (SENG).
When a data is sent from an external Modbus master (external device), the SCS’s CPU receives it through its serial communication module. The SCS’s CPU sends a response message using the Modbus slave communication function to the Modbus master in response to the data request.
The SCS Maintenance Support Tool displays error information and notifies the error status using the SCS status display function when an error in the serial communication module and communication content occurs.
Product Details:
Brand Name | YOKOGAWA |
Model | ALR121-S50 |
Condition | New |
Gross Weight/Shipping Weight | 2.2 lbs / 35.2 oz / 1kg |
Packing Size | 6.4" x 6.4" x 4.8" (16cm x 16 cm x 12 cm) |
Country of Origin/Original Country | United States (USA) |
Lead Time | In Stock |
Shipping Port | Xiamen |
Payment | T/T |
Sales Price | Inquiry |
Color | Depend on product |
Warranty | 12 months |
Lead time | 5-8 work days |
Courier partners | DHL, UPS, TNT, FedEx and EMS |
Additional Information:
Features | ||
Suffix Codes | -S | Standard type |
5 | With no explosion protection | |
E | With explosion protection | |
1 | With ISA Standard G3 | |
B | With ISA Standard G3 and temperature | |
Interface | RS-422/RS-485 (4-wire system) | |
Connection method | Point-to-point (RS-422) Multipoint (RS-485) | |
Communication function | Half-duplex | |
Synchronization method | Start-stop synchronization | |
Transmission speed | 1200/2400/4800/9600/19200/38400 bps | |
Transmission code | Binary | |
Character length | 8 bits (Fixed to 8 bit on the Modbus slave communication function and the subsystem communication function) | |
Stop bit length | 1/2 bits (Fixed to 1 bit on the subsystem communication function) | |
Parity check | None/even/odd | |
Lag time after data transmission | 1 ms | |
Transmission distance | Maximum 1200 m (total extended length) | |
I/O wiring | Cable with 3-pair shield, AKB161, or AKB162 | |
Wiring connection | Clamped with terminal block’s M4 screws (5 poles × 2 ports) | |
Communication function | Modbus slave communication function, subsystem communication function | |
Current consumption | 0.5 A |
Datasheet Link:Yokogawa ALR121-S50.pdf