Specifications
Brand Name :
TS
Model Number :
TS-ZZ011
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Payment Terms :
T/T, Western Union, MoneyGram, L/C, D/A, D/P
Supply Ability :
2000 sets per month
Delivery Time :
5-7 working days
Packaging Details :
Plywood box
Operating Voltage :
220V+10%/50HZ
Packaging Details: :
24v
Operating ambient temperature :
-40℃-70℃
Payment Terms: :
T/T, Western Union, MoneyGram, D/P, D/A, L/C
Supply Ability: :
2000 sets per month
Output Power :
150W
Description

Aayee Automatic Car Boom Parking Road Traffic Barrier Car Park Barrier Gate For Parking Access Control Security Boom Bar​Technical parameters

1 Working temperature(motor): -35℃~+85℃
2 Rated voltage:DC24V
3 Running speed:1.5s-8s
4 Rated current:8.58A
5 Rated power:140W
6 No-load speed:1850rpm
7 Rated speed:1400rpm
8 Output Power:56.8N.m
9 Relative humidity:≤90%
10 Remote control distance:≤100M(in the open place)


Features

1The running speed can be adjusted from 1.5s to 8s

3 Open the barrier gate by motor wheel when power off ,automatically reset after power on

4 Curved crank arm three- link movement structure, the operation is stable

5 Wireless remote control control open/close

6 Auto reverse function(force adjustable)

7 Infrared photocells connector is available

8 Loop detector connector is available.

9 Well-integrated with car parking system equipment,with wire control(must be switch signal)

10 Connector for traffic light(AC220V,power less than 40W)

11 Offering dry contact signal for car parking system(COM,NC,NO)


Arm length speed comparison table

Menu code Number Menu code name Defaults unit Remarks
H00-00 25-95 Open speed adjustment 40 Corresponding PWM duty cycle 25%-95%, step size is 1
H00-01 25-95 Close speed adjustment 40 Corresponding PWM duty cycle 25%-95%, step size is 1
H00-02 5-40 Open in place decelerate angle 35 The larger the angle value, the less likely it is to shake the arm when it is in place.
H00-03 5-40 Close in place decelerate angle 35 The larger the angle value, the less likely it is to shake the arm when it is in place.
H00-04 1-20 Open accelerate adjustment 10 ms The smaller the number, the faster the speed
H00-05 1-20 Close accelerate adjustment 10 ms The smaller the number, the faster the speed
H00-06 1-30 Open in place angle 2 degree step size is 1
H00-07 1-30 Open in place angle 1 degree step size is 1
H00-08 7-13 Auto reverse force adjustment 10 A step size is 1
H00-09 0-90 Delay closing adjustment 0 Sec step size is 100;0 is not closing automatically,,Other value will be closing automatically;This parameter is for when there is no loop detector signals and non-automatic operation occasions
H00-10 10-50 Self-check speed adjustment 30 Corresponding PWM duty cycle 10%-50%, step size is 1
H00-11 0-2 Self-check mode 0 0:no operate automatically;1:operate automatically,remove after power off;2:operate automatically,Power failure memory
H00-12 0-5 Self-lock force adjustment(Invalid) 3
H00-13 1-20 Motor deceleration time when paused 5 The larger the setting, the longer the pause time will take
H00-14 0-1 The default direction of operation after self-test 0 0:Closing,1:opening
H00-15 1-10 Number of pole pairs(Invalid) 4 Only used to correctly display motor speed values
H00-16 1-32 RS485communication address 1 Up to 32 slaves can be connected
H00-17 0-2 RS485communication rate 0 0:9600,1:19200,2:38400;Change the parameter and will be valid after power on again.
H00-18 0-1 If self-test after power is on 1 0:no self-test after power on,1:self-test after power on
H00-19 0-3 Manual self-test adjustment 2 0:Manually invalid,1:Keyboard SET button,2:remote control valid,3,Keyboard SET button and remote control both valid
H00-20 0-15 Monitoring parameter setting index 7 7,operation times(ms):0~9000
8,Cumulative operation times:0`99999999
9,automatically operation times :0~99999999
10,Collision times:0~99999999
11,Closing in place times:0~99999999
12,Power-on time (minutes):0~99999999
13,power-on times:0~99999999
14,Input port status:Binary display
15,Error code:0~7
H00-21 0-3 reset 0 1:rest adjustment
H00-22 0-1 LED output mode 0 0:Do not flash alternately during operation;1:Allow flashing

Installation, commissioning and use

7.1 Equipment installation

7.1.1 Please select the correct type of barrier gate according to the specifications of

the pace,and then fix the barrier cabinet with expansion bolts(refer to Figure 3).

After determined the position,the barrier gate foundation should be done according to the site conditions,and

also make the cast-in-place basement for the non-concrete ground.

7.4 Adjust the Position of Barrier Arm

To adjust the position of the arm (for example, after exerting excessive force), please take the steps as below:

  • open the barrier gate door and remove the cover
  • loosen the two fasten screws of the DZ-1 on the boom shaft with the M12's Allen wrench, so that the boom can be re-positioned by hand.
  • adjust the position of the boom (horizontal position, as shown in picture 1).
  • Use the hexagonal wrench to tighten the two fastening screws (72 Nm)

The parameter for selecting the balance tension spring

Arm Type The Length of arm Selection Spring

Type

Spec.(diameter*Length)
Straight Arm/Folding Arm 6M≥L>5M Extension Spring (ø5.5x280)+(ø4.5x280)
5M≥L≥4.5M (ø5.5x280)
4.5M>L≥3M (ø4.5x280)
Fence Arm 5M≥L≥4M (ø6.5x280)+(ø6.5x280)
4M>L≥3M (ø5.5x280)+(ø4.5x280)

(the parameter is based on the company’s arm)

Send your message to this supplier
Send Now

AC220 Infrared Car Park Boom Gate Automatic , DC Motor Security Barrier Gate

Ask Latest Price
Brand Name :
TS
Model Number :
TS-ZZ011
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Payment Terms :
T/T, Western Union, MoneyGram, L/C, D/A, D/P
Contact Supplier
AC220 Infrared Car Park Boom Gate Automatic , DC Motor Security Barrier Gate
AC220 Infrared Car Park Boom Gate Automatic , DC Motor Security Barrier Gate

Shenzhen tianshuo technology Co.,Ltd.

Active Member
4 Years
guangdong, shenzhen
Since 2007
Business Type :
Manufacturer
Total Annual :
1000000-50000000
Employee Number :
50~100
Certification Level :
Active Member
Contact Supplier
Submit Requirement