SICK GRL18S-F2336 | GR18 CYLINDRICAL PHOTOELECTRIC SENSORS
Features
Supply voltage UB 10 V DC ... 30 V DC 1)
Ripple < 5 Vpp2)
Current consumption 30 mA
Switching output PNP
Switching mode Dark switching
Signal voltage PNP HIGH/LOW VS - (≤ 3 V) / approx. 0 V
Output current Imax. ≤ 100 mA 3)
Response time < 500 µs 4)
Switching frequency 1,000 Hz 5)
Connection type Connector M12, 3-pin
Circuit protection A 6)
B 7)
D 8)
Protection class III
Polarisation filter ✔
Housing material Plastic, ABS
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied Fastening nuts (2 x)
Electromagnetic compatibility (EMC) EN 60947-5-2
Ambient operating temperature –25 °C ... +55 °C 9)
Ambient temperature, storage –40 °C ... +70 °C
UL File No. NRKH.E348498 & NRKH7.E348498
1) Limit values. Operated in short-circuit protected network: max. 8 A.
2) May not fall below or exceed UV tolerances.
3) At Uv > 24 V or ambient temperature > 49 °C, IA max. = 50 mA.
4) Signal transit time with resistive load.
5) With light/dark ratio 1:1.
6) A = VS connections reverse-polarity protected.
7) B = inputs and output reverse-polarity protected.
8) D = outputs overcurrent and short-circuit protected.
9) At Uv<=24V and IA<50mA.