SICK UE410-XU4T5 | Flexi Classic SAFETY CONTROLLERS
Features
Module I/O module
Configuration method Via rotary switch
Safety-related parameters
Safety integrity level SIL3 (IEC 61508)
Category Category 4 (EN ISO 13849)
Performance level PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 2.5 x 10-9 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)
Functions
Restart interlock Manual / automatic (configurable)
External device monitoring (EDM) ✔
AND operation ✔
OR operation ✔
Bypass ✔
Differentiation between man and material (muting) ✔
Interfaces
Inputs 4 safety inputs
4 switching inputs
Number of muting sensors 0 / 2
Outputs 4 safety outputs
2 test outputs
Delay time (outputs Q3/Q4) 0 s … 5 s
Connection type Plug-in spring terminals
Display elements LEDs
Electrical data
Protection class III (EN 61140)
Voltage supply Via A1, A2
Type of voltage supply PELV or SELV 1)
Supply voltage VS 24 V DC (19.2 V DC … 30 V DC)
Residual ripple ≤ 10 %
Power consumption ≤ 3 W (DC)
Internal power consumption ≤ 3 W (DC)
1) The current of the power supply that powers the module must be limited to a maximum of 4 A, either through the power supply itself or a fuse.
Mechanical data
Dimensions (W x H x D) 22.5 mm x 96.5 mm x 120.8 mm
Weight 180 g
Ambient data
Enclosure rating
Housing IP40 (EN 60529)
Terminals IP20 (EN 60529)
Ambient operating temperature –25 °C … +55 °C
Storage temperature –25 °C … +70 °C
Air humidity 15 % … 95 %, Non-condensing
Climate conditions according to EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity)
Electromagnetic compatibility (EMC) Class A (EN 61000-6-2, EN 55011)
Vibration resistance 5 g RMS, 5 Hz … 500 Hz (EN 60068-2-64)