AGM manufacture price Front Terminal 12v 150ah Deep Cycle Battery
>Precautions
• Always handle batteries with care.
• Always store upright.
• Never over-fill with acid.
• Always charge in a well ventilated place.
• Always wear eye protection when handling batteries.
• Wear protective clothing if there is any rick of acid splashing.
Cells Per Unit | 6 | ||
Voltage Per Unit | 12 | ||
Capacity | 100Ah @10hr-rate to 1.80V per cell @ 25℃ | 150Ah @10hr-rate to 1.80V per cell @ 25℃ | 200Ah @10hr-rate to 1.80V per cell @ 25℃ |
Weight | 31.0KG | 43.5KG | 61.0KG |
Max. Discharge Current | 1000A(5 sec) | 1500A(5 sec) | 1000A(5 sec) |
Internal Resistance | Approx. 5.5mΩ | Approx. 5.0 mΩ | Approx. 4.5 mΩ |
Recommended Maximum Charging Current Limit |
30A |
45A | 60A |
Operating Temperature Range | Discharge: -20℃~60℃ Charge:0℃~50℃ Storage:-20℃~60℃ | ||
Normal Operating Temperature Range | 25℃ ± 5 ℃ | ||
Float charging Voltage | 13.6 to 13.8V DC/unit Average at 25℃ | ||
Equalization and Cycle Service | 14.4to 14.6V DC/unit Average at 25℃ | ||
Self Discharge | Front triminal batteries can be stored for more than 6 months at 25℃. Self-discharge ratio less than 3% per month at 25℃. Please charge batteries before using. | ||
Size | 410*109*293MM | 550*110*290MM | 550*125*317MM |
Component | Positive plate | Negative plate | Container | Cover | Separator | Electrolyte | Safety valve | Terminal |
Raw material | Lead dioxide | Lead | ABS | ABS | AGM | Sulfuric acid | Rubber | Copper |
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.6V | 254 | 196 | 117 | 71.9 | 43.8 | 31.2 | 25.2 | 21.5 | 14.8 | 12.2 | 6.47 |
9.9V | 246 | 191 | 115 | 70.9 | 43.6 | 31.0 | 25.1 | 21.4 | 14.7 | 12.2 | 6.46 |
10.2V | 236 | 184 | 111 | 69.1 | 43.2 | 30.8 | 24.9 | 21.3 | 14.6 | 12.2 | 6.44 |
10.5V | 226 | 178 | 108 | 67.6 | 42.6 | 30.6 | 24.7 | 21.1 | 14.5 | 12.1 | 6.40 |
10.8V | 213 | 168 | 104 | 65.5 | 41.5 | 29.7 | 24.0 | 20.5 | 14.1 | 12.0 | 6.36 |
>Constant Power Discharge Characteristics(Watt,25ºC)
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.60V | 2741 | 2147 | 1313 | 820 | 508 | 367 | 297 | 255 | 176 | 146 | 77.7 |
9.90V | 2658 | 2096 | 1286 | 808 | 505 | 365 | 295 | 253 | 175 | 146 | 77.5 |
10.2V | 2549 | 2017 | 1247 | 787 | 500 | 362 | 293 | 251 | 174 | 145 | 77.3 |
10.5V | 2439 | 1950 | 1217 | 771 | 493 | 360 | 291 | 250 | 172 | 144 | 76.9 |
10.8V | 2302 | 1847 | 1172 | 747 | 480 | 349 | 282 | 242 | 167 | 143 | 76.3 |
>Warning
• Replacement of battery shall be performed as per following order. If failed, it may cause fire and explosion. Remove cable from negative terminal first.Connect cable to negative terminal last.
• When connect cable to battery, make sure not to get changed post of +and -. It may cause the damage of electronic components or fire.
• When ueing the battery ,handle with care,sulfuric acid may cause blindness or severe burn.
>Caution
• When moving battery, be careful not to drop the battery , which is heavy, Do not shake the battery with handle, if there is the handle, It may cause the injury.
• Do not shore the battery at the following places. High temperature and humidity. Being exposed to rain,snow, direct sunshine.