AGM Front Terminal Battery 12V 180Ah UPS battery backup Telecom Battery Wholesale lead acid battery Storage Battery
> Main Features
1. Designed floating charging service life: 12 years(25ºC); Long service life sealed lead acid battery.
2. Sealed and maintenance free operation VRLA battery.
4. Prominent high rate discharge performance ensures reliable performance in UPS and telecom applications.
5. The VRLA battery use special plate (Lead-calcium alloy with Sn) ensure long life of battery and low self discharge.
6. Wide operating temperature range from -20°C to +45°C
> Specification
Battery Model No. | FBR12V180FT | |
Nominal Voltage | 12V | |
Capacity(25ºC) | 20HR(5.25V) | 180Ah |
10HR(5.25V) | 158Ah | |
1HR(4.80V) | 108Ah | |
Dimension | Length | 560±2mm |
Width | 125±2mm | |
Height | 316±2mm | |
Total height | 316±2mm | |
Approx. Weight | 55.5kg±4% | |
Terminal type | F13 | |
Internal resistance | Approx 4.2mΩ | |
(Fully charged,25ºC) | ||
Capacity affected by | 40ºC | 102% |
temperature(20HR) | 25ºC | 100% |
| 0ºC | 85% |
| -15ºC | 65% |
Self-discharge | 3month | Remaining Capacity:91% |
(25ºC) | 6month | Remaining Capacity:82% |
| 12month | Remaining Capacity:65% |
Nominal operating temperature | 25ºC±3ºC(77ºF±5ºF) | |
Operating | Discharge | -15ºC-50ºC(5ºF-122ºF) |
temperature range | Charge | -10ºC-50ºC(14ºF-122ºF) |
| Storage | -20ºC-50ºC(-4ºF-122ºF) |
Float charging voltage | 13.5 to 13.8V | |
(25ºC) | Temperature compensation:-18mV/ºC | |
Cyclic charging voltage | 14.5 to 15V | |
(25ºC) | Temperature compensation:-30mV/ºC | |
Max charging current | 54A | |
Max discharging current | 1400A(5sec.) | |
Designed floating life(20ºC) | 12years |
> Structure and composition
Component | Positive plate | Negative plate | Container | Cover | Separator | Electrolyte | Safety valve | Terminal |
Raw material | Lead dioxide | Lead | ABS | ABS | AGM | Sulfuric acid | Rubber | Copper |
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.6V | 381 | 293 | 175 | 108 | 65.8 | 46.8 | 37.8 | 32.3 | 22.0 | 18.3 | 9.71 |
9.9V | 369 | 286 | 172 | 106 | 65.4 | 46.5 | 37.6 | 32.1 | 22.1 | 18.3 | 9.69 |
10.2V | 354 | 276 | 167 | 104 | 64.8 | 46.2 | 37.3 | 31.9 | 21.9 | 18.2 | 9.66 |
10.5V | 339 | 266 | 163 | 101 | 63.8 | 45.9 | 37.1 | 31.7 | 21.8 | 18.1 | 9.61 |
10.8V | 320 | 252 | 157 | 98.3 | 62.2 | 44.5 | 36.0 | 30.7 | 21.1 | 18.0 | 9.54 |
>Constant Power Discharge Characteristics(Watt,25ºC)
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.60V | 4111 | 3221 | 1969 | 1230 | 762 | 551 | 445 | 382 | 264 | 219 | 117 |
9.90V | 3987 | 3143 | 1929 | 1212 | 757 | 547 | 442 | 380 | 262 | 218 | 116 |
10.2V | 3823 | 3027 | 1870 | 1181 | 750 | 544 | 439 | 377 | 261 | 218 | 116 |
10.5V | 3659 | 2924 | 1825 | 1156 | 739 | 540 | 436 | 374 | 259 | 216 | 115 |
10.8V | 3453 | 2770 | 1758 | 1121 | 720 | 524 | 423 | 363 | 251 | 215 | 114 |
>Application
1. Front terminal series VRLA battery have been designed to be used in UPS system and telecom equipment.
2. Solar and wind energy storage system
3. Signal system , emergency lighting system , security system
4. Power source for portable devices or tools.
> Production Line
>Our Services
We accept OEM .
We accpet sample order for quality testing before production order.
After-Sale Service: Consultacncy and Technical Support
>Delivery & Payment Terms
Payment Terms | T/T | EXW | 30% in advance for deposit payment, the balance payments will be paid before shipment. | |
FOB | ||||
CFR/C&F | 30% in advance for deposit payment, the balance will be paid against copy of B/L | |||
CIF | ||||
L/C | For the amount of one shipment above 50,000 usd, L/C at sight is acceptable. | |||
Delivery Time | 30 days after receiving the payment or the deposit payment |