Specifications
Brand Name :
Acrel
Model Number :
AMC16-DETT
Certification :
IEC
Place of Origin :
Jiangsu, China
MOQ :
1 Pieces
Price :
62
Payment Terms :
T/T
Supply Ability :
8000 Piece/Pieces per Day
Delivery Time :
2-3 days
Packaging Details :
It is packed in a crash bag and then put into a cardboard box.
Accuracy Class :
1.0
Output Voltage :
200A/5V
Operating Temperature :
-20℃~+60℃
Product :
Acrel AMC16-DETT telecom station DC kwh consumption 6 channels meter
Communication :
RS485 Port
Certificate :
IEC
Installation :
Din Rail
Rated voltage :
-40V~-60VDC
Description

AMC16-DETT Base Station DC Energy Meter
Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. The meter could measure 6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software. have the functions of telemetering,teleindication,teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction. This meter can measure DC power consumption of three operators, providing detail datas for base station.

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

Acrel AMC16-DETT telecom station DC kwh consumption 6 channels meter

●DC rated voltage: 1 channel: -48VDC

●Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%

●RS485(MODBUS-RTU)

●LED display

●DIN 35 mm

Parameter

Input DC voltage 1 channel: -48VDC
DC current 6 channel hall current sensor,total DC200A/5V,Telecom, Mobile,Unicom and the 1st channel reserve 50A/5V, 2nd
channel reserve 100A/5V.
Grid power monitoring 1 channel: 0-5VDC
Overload capacity Voltage:1.2times continued,2 times continued 1s;
Current: 1.2 times continued,10 times continued 1s.
Accuracy (superposition hall sensors) 1%In≤I≤10%In error±2.5%; I>10%In error±2%
resolution Voltage output accuracy 0.01V; current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh
Functions Basic function Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED indicator display;485 communication
Metering function Start current: under rated voltage, when the load current value of the meter doesn’t exceed 1% of the max. current, the meter starts.
Shunt running current: when there is no current in the current circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator shall not have more than
Alarm function DC low voltage output alarm,DC high voltage output alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm, memory failure alarm and AC input power failure alarm
Timing function support broadcast timing, could remote timing to the meter by RS485
Hall CT power supply Power supply output:+12V/100Ma, -12V/50mA
Clock accuracy ≤0.5s/d(23℃),≤1s/d(-20℃~60℃)
Powe supply for ther meter -40VDC~ -60VDC
Power consumption ≤2W

Typical connection--AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

Wiring

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

Certification

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

Company profile

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

ACREL CO., Ltd. was founded in 2003 and successfully listed on GEM in 2012. ACREL is a high-tech enterprise that integrats R&D, production, sales and service. since its establishment, it committed to provide users with energy efficiency management and power security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

Since the listing in 2012, our company has maintained steady growth. The company will adhere to the concept of "innovation, efficiency, unity, integrity", adhere to steady operation and continuous innovation, and provide more high-quality products, services and solutions for power system users and micro-grid.

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels AcrelAMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

At Vietnam Power Equipment and Technology Exhibition, many customers from all over the world, our Acrel team has carried out detailed analysis and explanation of a series of difficult problems raised by customers. Under the enthusiasm of our technical team and sales team, the customer gave us a high evaluation of our products and services.

Acrel Co.,LTD [Stock Code:300286.SZ ] attended HANNOVER MESSE, is one of the few leading companies who provides various systematic of power monitoring, power control, energy management and electrical safety for smart grid users. Since 2003, we have been focused on the research, production and sales of intelligent electric meters and current sensors.

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

If you have any special requirements, for example another current ratio or special size ,please feel free to Contact Us.

FAQ

Q: Are you trading company or manufacturer ?

A: We are factory. Warmly welcome you to visit and investigate our factory.

Q: How long is your delivery time?

A: Generally it is 3-10 days if the goods are in stock. or it is 10-20 days if the goods are not in stock, it is according to quantity.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for lower price. If you place the order, all or part of the sample charge will be deducted from the goods. Please

contact us.

Q: What is your terms of payment ?

A: Usually, 100%TT in advance. If you have projects for another payment terms, please feel free to contact us.

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

Send your message to this supplier
Send Now

AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

Ask Latest Price
Watch Video
Brand Name :
Acrel
Model Number :
AMC16-DETT
Certification :
IEC
Place of Origin :
Jiangsu, China
MOQ :
1 Pieces
Price :
62
Contact Supplier
video
AMC16-DETT Telecom Station Dc Power Consumption Meter Kwh 6 Channels Acrel

Jiangsu Acrel Electrical Manufacturing Co., LTD.

Verified Supplier
5 Years
jiangsu
Since 2003
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
0.5million-1.5million
Employee Number :
1000~1500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement