Description
ADV offers a wide range of brazed aluminum radiator styles and options. From small individual coolers to large complex engine cooling systems, from heavy duty bar and plate construction to plastic tank radiators, we have the right design for your mobile or industrial application. Our engineering team is continually developing additional fin geometries to improve heat transfer efficiency so we can meet or exceed your expectations.
Fins are laid between aluminum braze sheets and fitted with header and face bars. The assembled unit is placed into one of our modern brazing furnaces where precise control of time and temperature produces a unified core. Manifolds designed to meet each customer's particular piping requirements are welded into place to complete the radiator.
Products Feature
LAB & Test
1.Leak Test of Every Unit
2.Performance Test
Performance Test: | Compressed Air System | Water Glycol System | Water Glycol System |
---|---|---|---|
Flow: | 0-48Nm3/min | 400L/min | 600L/min |
Temp: | ≤200°C | ≤100°C | ≤110°C |
Max. heating power: | 110KW | 180KW | 240KW |
3. Salty Spay Test
we can offer C5 standard preservative treatment preservative treatment, please contact us fr more information
Purchasing Guide
You just need to tell us your specific requirements and environmental parameters so that we can make professional quotations accordingly.
Please advise:
Oil parameter | Fluid | |
Flow | ||
Inlet temperature (℃) | ||
Cooling power (kw) | ||
Max. allowable pressure drop | ||
Max. work pressure (MPa) | ||
Air parameter | Flow | |
Inlet temperature (℃) | ||
Cooling power (kw) | ||
Max. allowable pressure drop | ||
Max. work pressure (MPa) | ||
Cool air parameter | Flow & Pressure curve | |
Inlet temperature (℃) | ||
Air trace | ||
Mounting | Max overall dimension | |
Location of connections | ||
Requirement of structure | ||
Working condition |