V-Bank Dry Cooler Air Condenser for data center office building
Dry coolers can play a significant role in helping a building operate more efficiently. Though this equipment is not known for conserving energy, it can be utilized as a condensing unit for a heat recovery chiller. The primary function of a heat recovery chiller is to provide heating or chilled water from energy that is normally wasted, but it can also provide chilled water to supplement a building’s primary chilled water system in the event of a shut down or failure. When a heat recovery chiller supplements a chilled water system, there must be a system to remove excess heat. This is the perfect application for a dry cooler, which serves as a condensing unit or cooling tower. In certain applications, this type of design can eliminate the need for water or air cooled chillers to be connected to the building’s back up power supply, which can potentially reduce the size of an emergency generator.
Application
Quality Details
Selection Data
630/800 V-Bank Air-Cooler Condenser selection data(2.11mm Fin Spacing) | |||||||||||
Model | Capacity | Exchange surface | Tube volume | Air flow | Sound Pressure Level | Fan Data | No. of fans | Connection | Weight | ||
kW*1 | ㎡ | L | m3/h | dB(A)10m | 3~400/50 | mm | mm | kg | |||
W | A | N*D | Inlet | Outlet | |||||||
HCVS163-0062 | 62 | 142 | 23.3 | 18281 | 61 | 1600 | 3.2 | 1*630 | 2*34.9 | 2*22.23 | 300 |
HCVS163-0067 | 67 | 189 | 31.1 | 17779 | 61 | 1600 | 3.2 | 1*630 | 2*34.9 | 2*22.23 | 325 |
HCVS263-0127 | 126 | 284 | 46.6 | 36539 | 62 | 3200 | 6.4 | 2*630 | 2*34.9 | 2*22.23 | 455 |
HCVS263-0140 | 140 | 378 | 62.1 | 35505 | 62 | 3200 | 6.4 | 2*630 | 2*34.9 | 2*22.23 | 502 |
HCVS363-0187 | 187 | 425 | 69.9 | 54841 | 63 | 4800 | 9.6 | 3*630 | 2*41.3 | 2*28.6 | 610 |
HCVS363-0207 | 207 | 567 | 93.2 | 53290 | 63 | 4800 | 9.6 | 3*630 | 2*41.3 | 2*28.6 | 679 |
HCVS463-0253 | 253 | 567 | 93.2 | 73079 | 64 | 6400 | 12.8 | 4*630 | 2*41.3 | 2*28.6 | 729 |
HCVS463-0280 | 280 | 756 | 124.3 | 71010 | 64 | 6400 | 12.8 | 4*630 | 2*41.3 | 2*28.6 | 820 |
HCVS563-0315 | 315 | 709 | 116.5 | 91376 | 65 | 8000 | 16.0 | 5*630 | 2*54 | 2*35 | 860 |
HCVS563-0353 | 353 | 945 | 155.3 | 88735 | 65 | 8000 | 16.0 | 5*630 | 2*54 | 2*35 | 980 |
HCVD463-0218 | 218 | 434 | 69.9 | 70363 | 64 | 6400 | 12.8 | 4*630 | 2*41.3 | 2*28.6 | 533 |
HCVD463-0250 | 250 | 578 | 93.2 | 67346 | 64 | 6400 | 12.8 | 4*630 | 2*41.3 | 2*28.6 | 641 |
HCVD663-0338 | 338 | 651 | 104.8 | 105416 | 66 | 9600 | 19.2 | 6*630 | 2*54 | 2*35 | 765 |
HCVD663-0375 | 375 | 868 | 139.8 | 101019 | 66 | 9600 | 19.2 | 6*630 | 2*54 | 2*35 | 873 |
HCVD863-0451 | 451 | 868 | 139.8 | 140554 | 67 | 12800 | 25.6 | 8*630 | 2*54 | 2*35 | 1025 |
HCVD863-0500 | 500 | 1157 | 186.4 | 134692 | 67 | 12800 | 25.6 | 8*630 | 2*67 | 2*41.3 | 1133 |
HCVD1063-0561 | 561 | 1084 | 174.7 | 175747 | 68 | 16000 | 32.0 | 10*630 | 2*67 | 2*41.3 | 1275 |
HCVD1063-0633 | 633 | 1446 | 233.0 | 168365 | 68 | 16000 | 32.0 | 10*630 | 2*67 | 2*41.3 | 1385 |
HCVD1263-0681 | 681 | 1301 | 209.7 | 210831 | 69 | 19200 | 38.4 | 12*630 | 2*67 | 2*41.3 | 1420 |
HCVD1263-0750 | 750 | 1735 | 279.6 | 202038 | 69 | 19200 | 38.4 | 12*630 | 2*67 | 2*41.3 | 1636 |
HCVD1463-0796 | 796 | 1518 | 244.6 | 245970 | 70 | 22400 | 44.8 | 14*630 | 2*76.3 | 2*54 | 1650 |
HCVD1463-0883 | 883 | 2024 | 326.2 | 235711 | 70 | 22400 | 44.8 | 14*630 | 2*76.3 | 2*54 | 1883 |
HCVD1663-0917 | 917 | 1735 | 279.6 | 281022 | 71 | 25600 | 51.2 | 16*630 | 2*76.3 | 2*54 | 1840 |
HCVD1663-1016 | 1016 | 2313 | 372.8 | 269298 | 71 | 25600 | 51.2 | 16*630 | 2*76.3 | 2*54 | 2135 |
HCVD1863-1022 | 1021 | 1952 | 314.5 | 316247 | 72 | 28800 | 57.6 | 18*630 | 2*76.3 | 2*54 | 2050 |
HCVD1863-1149 | 1149 | 2603 | 419.4 | 302863 | 72 | 28800 | 57.6 | 18*630 | 2*76.3 | 2*54 | 2385 |
HCVD2063-1282 | 1282 | 2892 | 466.0 | 336514.8 | 73 | 32000 | 64.0 | 20*630 | 2*89 | 2*54 | 2633 |
HCVD480-0251 | 251 | 510 | 83.9 | 80279 | 54 | 7200 | 15.2 | 4*800 | 2*41.3 | 2*35 | 735 |
HCVD480-0276 | 276 | 681 | 111.8 | 74879 | 54 | 7200 | 15.2 | 4*800 | 2*54 | 2*41.3 | 835 |
HCVD680-0381 | 381 | 766 | 125.8 | 120418 | 56 | 10800 | 22.8 | 6*800 | 2*54 | 2*41.3 | 1135 |
HCVD680-0413 | 413 | 1021 | 167.8 | 112318 | 56 | 10800 | 22.8 | 6*800 | 2*67 | 2*41.3 | 1225 |
HCVD880-0411 | 411 | 1021 | 167.8 | 120430 | 58 | 14400 | 30.4 | 8*800 | 2*67 | 2*41.3 | 1617 |
HCVD880-0552 | 552 | 1361 | 223.7 | 149758 | 58 | 14400 | 30.4 | 8*800 | 2*67 | 2*41.3 | 1753 |
HCVD1080-0634 | 634 | 1276 | 209.7 | 200697 | 60 | 18000 | 38.0 | 10*800 | 2*76.3 | 2*54 | 1894 |
HCVD1080-0693 | 693 | 1702 | 279.6 | 187197 | 60 | 18000 | 38.0 | 10*800 | 2*76.3 | 2*54 | 2042 |
HCVD1280-0827 | 827 | 2042 | 335.5 | 224637 | 62 | 21600 | 45.6 | 12*800 | 2*76.3 | 2*54 | 2327 |
HCVD1480-0954 | 954 | 2382 | 391.4 | 262076 | 64 | 25200 | 53.2 | 14*800 | 2*89 | 2*54 | 2741 |
HCVD1680-1104 | 1104 | 2723 | 447.3 | 299516 | 66 | 28800 | 60.8 | 16*800 | 2*89 | 2*54 | 2947 |
HCVD1880-1286 | 1286 | 3063 | 503.3 | 336576 | 66 | 32400 | 68.4 | 18*800 | 2*89 | 2*54 | 3342 |
1. Capacity based on sub-cooling 0K,ambient temp of 35℃,condensing temp of 50℃,suctio temp of 100℃,R404A.. | |||||||||||
2. The sound pressure level data are average tested at the intersection of fan plane and reflection plane 10meters from axis |
OEM Customation
Frame | Fin | Heat-exchange Tube | Fan | Electric Control | Other |
---|---|---|---|---|---|
Hot dip galvanized steel | Hydrophilic Fin | Stainless steel 304 | EC Fan | Junction Box | HT/LT Double-Bank Heat-exchange |
Stainless steel 304 | Almg 25 | Stainless steel 316 | Explosion-proof fan motors | safety Switch | Adiabatic Water spraying system |
Stainless steel 316 | Copper Fin | B10 | Marine Fan Motor | Control Box | Steel Structure and safe access for service |
Aluminum | Pre-coated Epoxy Fin | B30 | Stainless Steel Guards | VFD Control Box | Air filter |
| Copper Tinned Fin | Titanium |
| Temperature/Pressure Control Box |
|
| Heresite/ Blygold/Epxoy Coated Fin |
|
|
|
|
Advantages
Design software | Using the mature European design software, according to the EN1048 and actual demand accurate design of heat exchanger, can design the special low temperature cold agent etc. |
Heat exchange structure | Supported to the casing by means of a "flating-bed " system that avoids any kind of contact between the heat-exchange tubes and the supporting end plates,assuring a long life for the heat-exchange without leaks. Heat-exchange sections separated and independent for each fan. The standard fin spacing is 2.1mm,Fin pitch up to 12mm for low air pressure drop. |
Condenser structure | Shape with flexible and changeable,--Flat-bed,W-Bank,V-Bank; Fan direction--blowing and sucking. Finned length up to 12m,Finned height up to 2.7m. |
Heat Exchange Tube | Using copper content more than 99.9% pipe,using three type copper tube 3/8",1/2",5/8" Increased the thermal efficiency and low fluid pressure drop . |
Casing | Using galvanized sheet case, spraying outdoor powder coatings, and after high temperature curing, high strength of corrosion resistance is strong, the standard color for RAL9003. |
Fans | Low noise axial fans,with maintenance free motors in protection class IP 54,Internal motor protection with thermo contacts.With precise design, forming mould processing, air volume is larger and more efficient. |
Purchasing Guide
You just need to tell us your specific requirements and environmental parameters so that we can make professional quotations accordingly.
Please advise:
Oil parameter | Fluid | |
Flow | ||
Inlet temperature (℃) | ||
Cooling power (kw) | ||
Max. allowable pressure drop | ||
Max. work pressure (MPa) | ||
Air parameter | Flow | |
Inlet temperature (℃) | ||
Cooling power (kw) | ||
Max. allowable pressure drop | ||
Max. work pressure (MPa) | ||
Cool air parameter | Flow & Pressure curve | |
Inlet temperature (℃) | ||
Air trace | ||
Mounting | Max overall dimension | |
Location of connections | ||
Requirement of structure | ||
Working condition |
Be free to contact us if you need any further information, thank you!