Smart And Automatic Aerosol Fire Suppression Device With 80g Agent
Specification details
1. Product name: FireLess 2.0A
2. Fire extinguishing agent quantity: 0.08kg
3. Product weight: 0.205kg
4. Appearance look: Small cylinder
5. Extinguishing fire classes: A,B,C,E
6. Discharge time: ≤6s
7. Product appearance color: red
8. Product diameter: 85mm
9. Product height: 49mm
10 . Durable time:10 years
11. Max/min ambient temperature: -50℃-95℃
12. Humidity:≤95%
The elements of combustion
Combustion without a flame is called glowing fire, the required conditions of combustion as following:
1. Have a certain amount of flammable and combustible material
2. Adequate amount of oxygen
3. A sufficient amount of heat that can cause flammable substances
In order to burn combustibles, there are three conditions must be simultaneously present, each condition has a certain amount.
The technical specifications
Product model | FireLess 2.0A |
Overall dimension | Φ85mm X49(H) mm |
Weight of device | 205g |
Agent quantity | 80g |
Protected volume | 2.0m3 |
Activation method | Electric start, heat-sensitive start, or mechanical temperature sensing self-starting |
Ambient temperature | -50℃~+95℃ |
Discharge time | ≤6s |
Service life | 10 years |
Appearance shape | Small cylinder |
Extinguishing fire class | A,B,C,E |
Surface color | red |
Surface insulating paint | Yes |
HS code | 842410000 |
Fire suppression method
The method of extinguishing is intended to eliminate one or more of the required combustion conditions so that combustion does not continue. The basic conditions for each type of combustion correspond to a method of extinguishing fire. The inhibitory effect of different fire extinguishing agents (fire extinguishing mechanism) can be based on eliminating a required combustion condition.Fire extinguishing methods are:
1. Remove combustible materials/ fuels
Clearing is a mechanical operation where flammable and combustible substance is removed from the fire
2. Remove heat
Lowering the fire temperature and make the temperature is in sufficiently cold conditions, the fire reaction is no longer continuing.
3. Remove oxygen
When smothering a fire, the oxygen is removed or it is prevented from getting oxygen continuously in the burning room. The extinguishing agent is to displace the oxygen or lower the oxygen concentration to a level at where combustion cannot continue.
Applications and Limitations
FireLess aerosol systems shall be installed around the hazards to protect the objects
Condensed aerosol fire extinguishing systems can extinguish the fires on ordinary
combustible materials, such as paper, wood, cloth, rubber and many plastics (Class A surface fires), flammable or combustible liquids (Class B fires) or energized electrical equipment (Class C fires).