Item :
Aerosol Based Automatic Fire Suppression Systems For Server Rooms And Data Centre
Source :
Chinese Military
Protected volume (m³) :
100/50/125/35 m³
Start mode :
thermal line temperature sensing/ mechanical temperature sensing/electric start
Discharge time(s) :
≤2~19s
Environmental :
non-ozone depleting
Description

Aerosol Based Automatic Fire Suppression Systems For Server Rooms And Data Centre

Why server rooms and data centres need fire suppression?

Fire suppression systems for server rooms and data centres are essential to the server room itself. A fire suppression system will automatically extinguish a fire without the need of human intervention. Fire suppression systems for data centres must be suitable for clean air environments, as server rooms and data centres are mostly occupied by personnel.
The designs standards for Fire suppression systems for server rooms and data centres are carried out with strict guidelines, as the fire suppression agents used can be dangerous if not designed correctly. We recommend our Fireless aerosol based fire suppression system for server rooms, because the aerosol agent released is no harm to people and equipments, non-corrosiveness to normal equipment except for high-precision instrumentation.

A typical server room will require as below:

  • Fireless Aerosol Based Fire Suppression Systems which includes Fireless generator and HD101 temperature sensor
  • Smoke detection : a minimum of two smoke detectors, irrelative of the room size
  • Audible alarms: bells and sounders, these will indicate an audible alarm for fire which has been detected in the room and alarm warning of an imminent fire suppression aerosol release
Product model FireLess 50 FireLess 100 FireLess 125 Fireless 35
Overall dimension 240(diameter)X69(height) 240(diameter)X110(height) 240(diameter)X126(height) 240(diameter)X57(height)
Weight of device 3.4kg 5.3kg 6.8kg 1.0kg
Agent quantity 1.4kg 2.8kg 3.5kg 2.9kg
Protected volume 50m3 100m3 125m3 35m³
Activation method Electric start Electric start Electric start Electric start
Discharge time ≤9s ≤15s ≤19s ≤7s
Start current (mA, DC) ≥700 ≥700 ≥700 ≥700
Safe current (mA, DC) ≤150 ≤150 ≤150 ≤150
Service life 10 years 10 years 10 years 10years
Installation type Fixed Fixed Fixed Fixed
Original place China China China China
Color Red Red Red Red

What Suppression System Works Best in Computer Rooms?

Since Halon, the former predominant fire suppression system agent, was revealed to be environmentally destructive to the ozone, companies have looked toward other alternatives such as clean agent systems and inert gases to solve their need for computer room fire systems. Like Halon, both clean agent and inert gas systems provide safer options for the preservation of sensitive electronics by avoiding the risk of water damage.

Clean agent fire suppression systems use chemical-based agents to absorb the heat of a fire. Fireless is a leading product in fire protection for computer rooms, data centres, art galleries, Medical Centres & labs, Archives, Diesel Generators and more. Fireless is non-ozone depleting with short atmospheric lives. They are non-conductive, as well as non-corrosive which protects against damage caused by the act of extinguishing the fire as with other suppression agents like chemicals and water. In addition, they leave no residue and, as a result, avoid costly and time-consuming post-fire cleanups.

The following will most likely occur if you don't have the right system in place:

Service disruptions to customers

Damage or destruction of expensive electronic equipment requiring repair or replacement

Loss of vital databases

Costly and time-consuming site cleanup and repairs from fire and water damage

Portable Aerosol Can Fire Extinguisher For Data Center Generator Server Rooms

Send your message to this supplier
Send Now

Portable Aerosol Can Fire Extinguisher For Data Center Generator Server Rooms

Ask Latest Price
Brand Name :
Fireless
Model Number :
Fireless 100/50/125/35
Certification :
BSI
Place of Origin :
Jiangsu
MOQ :
1
Price :
Negotation
Contact Supplier
Portable Aerosol Can Fire Extinguisher For Data Center Generator Server Rooms
Portable Aerosol Can Fire Extinguisher For Data Center Generator Server Rooms
Portable Aerosol Can Fire Extinguisher For Data Center Generator Server Rooms
Portable Aerosol Can Fire Extinguisher For Data Center Generator Server Rooms

Novtec Technology Co .,Ltd

Active Member
7 Years
jiangsu, suzhou
Since 2003
Business Type :
Manufacturer, Exporter
Total Annual :
15000-30000
Employee Number :
100~1500
Certification Level :
Active Member
Contact Supplier
Submit Requirement