Total Flooding Extinguishing System Aerosol Fire Suppression Generators
What is total flooding extinguishing system?
A system arranged to discharge an extinguishant into an enclosed space to achieve a uniform distribution of that extinguishant, at or above the design application density, throughout the space.
How does the FireLess 2.0 work?
The FireLess 2.0 will work when the heat-sensitive line is burning and activated the release of the fire extinguishant and a great deal of subnanometer solid phase particles and inert gas mixture, namely aerosols, are rapidly produced to act on every corner of the fire through a total flooding way and fully infuse the protected space so as to quickly put out the fire.
Specification
Product type | Fixed type |
Product name | FireLess 2.0 |
dimension | H79mm, D150mm |
Product weight | 1.46kg |
Protected volume | 2 m3 |
Fire extinguishing agent quantity | 0.16kg |
Extinguishing fire class | A,B,C, |
Operation ways | Automatic/manual |
Compatibility | Good, connect with various alarm system |
Lead time | 45-60days after get the payment |
Fire extinguishing agent status | Solid Aerosol-Forming Compound |
The Fire extinguishing way of extinguishant | Total flooding |
Classifications for Fires
Class A Fires. Fires in ordinary combustible materials, such as wood cloth, paper, rubber, and many plastics. |
Class B Fires. Fires in flammable liquids, combustible liquids, petroleum greases, tars, oils, oil-based paints, solvents, lacquers, alcohols, and flammable gases. |
Class C Fires. Fires that involve energized electrical equipment. |
Volume enclosed by the building elements around the protected enclosure, minus the volume of any permanent impermeable building elements within the enclosure.
The advantages of FireLess 2.0
1. Eco-friendly and harmless to man ,animals and environment. Zero ODP, CFC-free and zero GWP. ODP=Ozone Depletion Potential, CFC-free = Chlorofluorocarbon-free, GWP=global warming potential. The halon fire extinguishers were forbidden to use because it generate the substances which is destroy the ozone, through, it has high fire extinguishing efficiency. As the best alternative for the Halon extinguishers, FireLess 2.0 made a great innovation and have a good performance on environment protection and fire extinguishing efficiency. |
2. Smaller volume and lighter weight. Compare to the civil aerosol fire extinguishing devices, FireLess 2.0 has smaller occupied space and lighter weight. But the fire extinguishing performance is better.
|
3. Minimal cost of maintenance and installation. Because it is non-pressurized, no need to maintain it often, the time and cost are saved. The owner also has no need to plan the space use, because it is no need of any pipe network construction.
|
4. Widely use range, cover many many industries. Especially for All kinds of electrical cabinets in transportation, power, energy, |
Product certificate
Our products have passed the testing of the national fixed fire extinguishing system and fire-resistant components quality testing center, obtained the Marine products type approval certificate, passed the application environment test (vehicle, cabinet, wind turbine) and obtained the relevant report.Product implementation of the ministry of public security fire products ga499.1-2010 product standards.Fire experts and professional and technical personnel for several years after a large number of experimental verification, and in a variety of complex environments around the test and application, to ensure that the product in theory and practice are amenable to test.