Specifications
Brand Name :
15 Minutes COVID-19 Test Kit Antigen Rapid Test Kit Standard Q Art Test Kit
Model Number :
2019-nCoV Antigen
Certification :
CE BfArm
Place of Origin :
China
MOQ :
To be negotiated
Price :
To be negotiated
Supply Ability :
10000 Kit/Kit per Day
Delivery Time :
To be negotiated
Packaging Details :
Kit
Type :
Coronavirus Test Kit
Certificate :
CE BfArm
Validity Period :
18 months.
Sample :
Oropharyngeal sample,Nasopharyngeal sample.
Storage Condition :
Store at 2℃~30℃,After the aluminum foil bag is opened,the validity period is 1 hour.
Benefits :
High Accuracy;Results in 15 minutes;Easy to Use;No Equipment required;Wide range of applications
Wide range of application :
Suitable for hospitals,communities,airports,stations,customs,schools,enterprises etc.
Description

15 Minutes COVID-19 Test Kit Antigen Rapid Test Kit Standard Q Art Test Kit

Intended Use


This product uses cross-current immunoassay to be used for qualitative testing of the novel coronavirus antigen in nasopharyngeal and oral pharyngeal swabs of suspected patients.
Wide range of applications: suitable for hospitals, disease control centers, communities, airports, train stations, customs, schools, businesses, etc..

Sample Requirements


【Sample Requirements】
We recommend aseptic sampling using a polyester sponge with a PP (polypropylene) stick.
(1) How to grate the oropharyngeal specimen: The subject tilts his head slightly and opens his mouth to expose the amygdala of the pharynx on both sides. Wipe both sides of the pharyngeal amygdala at least 3 times through the root of the tongue. Then wipe above and below the posterior wall of the pharynx at least three times.
(2) How to grate the nasopharyngeal sample: The grabber lightly supports the grabbed person's head with one hand, holds the wipe with one hand, inserts it into the nostril, and slowly back along the bottom of the inferior nasal passage. Infiltrate. The nasal meatus is bent, so use excessive force to avoid traumatic bleeding. When the tip reaches the posterior wall of the nasopharynx, gently turn it once (stop for a while if you have a reflex cough) and slowly remove it.
(3) Sample processing: The swallowed sample must be treated with the sample buffer provided by this kit as soon as possible (if not treated immediately, it must be dried, sterilized and stored in a sealed plastic tube immediately. Do not), and store at 2 ° C-8 ° C for no more than 24 hours; store at -70 ° C for extended periods of time, but avoid repeated freeze-thaw.

Test Method


Bring all reagents to room temperature before testing. The test should be conducted at room temperature.
I. Sample extraction (see Figure 1)
1. Put 400 μL (about 10 drops) of buffer solution vertically in the sample extraction tube, insert it into the solution, bring it close to the inner wall and rotate it about 10 times to dissolve as much as possible.
2. Squeeze the tip of the sample along the inner wall of the extraction tube, leave as much liquid as possible in the tube, and take out the sample.
3. Cover the transmitter.

COVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test Kit

II. Test Procedure (See Figure 2)

1. Remove the test card from the sticker bag.
2. Add 2 drops (about 80 μl) of the treated sample extract to the addition hole of the test card and activate the timer.
3. Place the test card at room temperature for 15 minutes before reading the results. After 20 minutes, the result was invalid.

COVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test Kit

Interpretation of test results


COVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test Kit

(1) Invalid result: The test was invalid because the reaction line did not appear on the quality control line (C line). This experiment should be redone.
② Negative result: Red ribbon, color of quality control line (C line).
③ Positive result: Two red bands, test line (T line) and quality control line (C line) are both displayed in color.

Company profile


COVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test KitCOVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test KitCOVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test KitCOVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test Kit
Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

Zhongxiu Qualifications


DOC

COVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test Kit
Send your message to this supplier
Send Now

COVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test Kit

Ask Latest Price
Brand Name :
15 Minutes COVID-19 Test Kit Antigen Rapid Test Kit Standard Q Art Test Kit
Model Number :
2019-nCoV Antigen
Certification :
CE BfArm
Place of Origin :
China
MOQ :
To be negotiated
Price :
To be negotiated
Contact Supplier
COVID-19 2019-NCoV Antigen Rapid Cross Current Immunoassay Coronavirus Test Kit

Henan Lantian Medical Supplies Co.,Ltd.

Active Member
4 Years
henan, zhengzhou
Since 2016
Business Type :
Manufacturer, Exporter, Seller
Employee Number :
500~1000
Certification Level :
Active Member
Contact Supplier
Submit Requirement