80000pcs/yearCryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
Delivery Time :
1-30 working days
Packaging Details :
standard export package, or as per customer request
Heating Type :
Multi-power Heat
Performance COP (C.O.P.) :
5.0
Max Pool Volume (m3 / Gal) :
600 / 158400
Water Side Heat Exchanger :
Shell & Tube
Operating Voltage :
220-380-410V
Application :
Villa Family, Sauna and Swimming Pool, Hotels
Description

45 kw CO2 Cascade AC Inverter Heat Pump Integral ultra-low temperature cascade carbon dioxide heat pump
1. Liquid crystal display; carbon dioxide heat pump variable frequency drive, R134a unit is fixed frequency;

2. Refrigerant: carbon dioxide (R744) + R134a;

3. Setting range: heating 65/40℃, cooling 7/12℃;

4. Working condition: -45-43℃;

5. The CO2 heat pump unit and the R134a unit work at the same time during heating in winter;

6. The carbon dioxide heat pump unit adopts Italian Duling compressor;

7. Function: low temperature heater.

CO2 Refrigerant: Advantages

①Non-flammable, non-toxic.

② Natural product.

3Does not require any special procedures to recover refrigerant

4 No need to reacquire.

5 No damage to the Ozone Layer.

6.ODP=0 (Ozone Threat Potential Value 0)2

7.GWP=1(Greenhouse Effect Potential Value 1)

8.Not subject to any country's tax and regulatory regulations.

Advantages for CO2 R744 Heat Pump:

1The water temperature can be up to 100℃, high temperature storage can reduce the volume of the water tank.

2 The working limit is-43℃, but the water still can be discharged efficiently.

3 Maximum COP is 5.5.And for the All-in-one Multifunctional Machine, its Maximum COP is 7.

4 All-in-one Machine can produce hot and cold water at the same time to achieve maximize the efficiencial energy utilization.

5.Can meet different water consumption.

6 Single mechanism coaxial 520kW can be combined with multiple modules.

⑦ Safety, with 6times for overpressure safety protection, water and electricity separation.

⑧ Intelligent frequengy conversion control can save 50% of the energy when defrosting.

9.Split design, especially for high-rise places that cannot be hoisted and transported.

10. Smart wireless APP control, can realize unmanned management.

8kW household carbon dioxide all-in-one machine CO2 air source heat pump multifunctional

45 kw CO2 Cascade AC Inverter Heat Pump Integral ultra-low temperature cascade carbon dioxide heat pump

1.DC variable frequency two-stage compressor.

2. The Split-Type Machine can be configured with a maximum water tank volume is 2000L.

3.Integrated built-in water tank volume as 40L,180L, 220L, 260L, 320L

④ Product Functions: Single Hot Water Unit Machine, Water Boiler,Domestic Hot Water+ Heating+ Solar Heating.

(5 Suitable for houses, illas,small hotels, small factories, hospital disinfection, etc.

CO2Cascade AC Inverter Heat Pump

① AC inverter compressor.

② CPP/PLC main control, colorful touch screen.

3 Ultra-low temperature operation-43℃C.

④ Split or whole body machine, can be customized as prefer.

⑤ Product Function: Ultra-low Temperature Heating in winter, Cooling in summer.

3.Applicable to places requiring heating such as northern high-speed railway stations,supermarkets, factories, stadiums, hot 45 kw CO2 Cascade AC Inverter Heat Pump Integral ultra-low temperature cascade carbon dioxide heat pump els, farms etc.

CO2 Cascade AC Inverter Heat Pump

45 kw CO2 Cascade AC Inverter Heat Pump Integral ultra-low temperature cascade carbon dioxide heat pump

Type LNF-45XW LNF-85XW LNF-125XW
Function Heating Capacity kW 46 84 125
Hot Water Capacity L/H 8 14.5 21.4
Heating Power Input kW 12.4 26.3 40.3
COP W/W 3.7 3.2 3.1
Power Supply V/Ph/Hz 380V~ 415V~-50/60Hz
Rated Output Water Temperature 60
Maximum Output Water Temperature 70
Working Ambient Temperature Range (-)43-43
Water Connection Pipe Size mm DN32 DN40 DN50
Refrigerant Type R744/CO2+R134a
Dimensions mm 1803x830x2100 2045x1108x2300 2470x1370x2415
Noise Level dB(A) 52 56 66
Net Weight KG 620 1185 1500
Inverter AC
Standard Temperature Condition:
Outdoor Dry Bulb Temperature 7"C Wet Bulb Temperature 6°C, Return Water Temperature 50°C Water Supply Temperature 55℃;

Application Diagram Pressure-bearing water tank

8kW household carbon dioxide all-in-one machine CO2 air source heat pump multifunctional

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw

System Diagram Smart Control System

8kW household carbon dioxide all-in-one machine CO2 air source heat pump multifunctional

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw


System schematic diagram

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw


Send your message to this supplier
Send Now

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw

Ask Latest Price
Watch Video
Brand Name :
LN
Model Number :
SJKRS-05I/C
Certification :
CE ISO CCC ROHS
Place of Origin :
China
MOQ :
Negotiable
Price :
Negotiable
Contact Supplier
video
CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw
CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw
CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw

Maanshan Ruika Metal Products Technology Co., Ltd.

Active Member
5 Years
anhui
Since 2002
Business Type :
Manufacturer, Exporter, Trading Company, Seller
Total Annual :
1.MILLION-2MILLION
Employee Number :
50~150
Certification Level :
Active Member
Contact Supplier
Submit Requirement