Compressor Brand :
Copeland
ASHP Heating Capacity :
EVI 10.5KW 20kw 38.5kw heat pump
mbient Temp of Using :
Minus 25C-43C
Max water temperature :
55-60C
Compressor :
Mitsubishi* Compressor for EVI Air Source Heat Pump
Function :
Radiator, Fan Coil Unit, Floor Heating Cooling & domestic or commercial Hot Water
SUITABLE HEATING SPACE :
TYPE OF HEAT PUMP USING AREA MODEL NAMEMonobloc Heat Pump 10.5KW (60-100m2) B3SD Monobloc Heat Pump 20KW (150-200m2) B5SD Monobloc Heat Pump 38.5KW (250-300m2) G10D
HEAT PUMP TYPE :
Monoblock EVI Heat Pump Air to Water Heat Pump 10.5KW-20KW-38.5KW-Heating and DHW
Heat source :
Air source heat pumps
Incoterm :
FCR, FOB, CFR,CIF,DDU,DDP
Service :
OEM
Description

Air Source Heat Pump Air Conditioning Low Temperature Mini Split Heat Pump

The ultra-low temperature air source heat pump adopts an ultra-low temperature compressor commonly used in cold regions of Europe and a low-temperature high-efficiency environmentally friendly refrigeration system 410A. The heating energy efficiency at low temperature (-25℃) is 50%-80% higher than that of conventional air source heat pump units. Ultra-low temperature air When the ambient temperature drops sharply, the heating capacity attenuates little by the source heat pump unit, which fully guarantees the heating effect. The EU market users generally use room heating in cold areas in winter and produce domestic hot water.

air source heat pump air conditioning low temperature mini split heat pump

EVI air source heat pumps Features
• Powerful heating at low temperature Adopting the technology of supplemental air and increasing enthalpy, it can run efficiently even at -25℃.

• High efficiency and energy saving

Adopting SCL heat exchange technology, no electric auxiliary heat, high energy efficiency ratio.

air source heat pump air conditioning low temperature mini split heat pump

The refrigerant from the condenser is undercooled and then throttled, and then entered the evaporator to melt the frost layer on the evaporator. Compared with the commonly used reverse cycle defrosting, there are essential differences.

(1) Defrosting in the normal heating at the same time, does not affect heating and indoor load.

(2)It can better adapt to the defrosting requirements of fin heat exchanger in different environments and different parts, and do point-to-point accurate defrosting.

(3) Defrosting does not require any other energy, continuous constant heating efficiency.

(4) Set in the light frost, the frost will be removed, so that the unit in the frost-free state of operation.

Automatic scale removal and unique nitrogen bead antifreeze technology can effectively extend the high efficiency of heat exchanger service time and heat transfer efficiency.

Single chip microcomputer is a single chip microcontroller, chip integrated computer system, equivalent to a micro computer. single chip microcomputer control system logic control careful, small volume, light weight, strong stability, can deal with various operating conditions and protection measures.

Adopt EVI air injection technology, double stage compression, improve heating efficiency, even under -25° C environment can be efficient operation.

Adopts gold aluminum fin evaporator technology, precious metal nano double layer coating, defrosting more quickly. Effectively improve the evaporation efficiency of air and rain water, dust is not easy to accumulate, to ensure that -25℃ can also have a strong heat transfer.

Triple sound insulation and heat insulation

· The machine adopts triple sound insulation cotton, together with special shock absorbing pad, equipment foundation platform and customized fan, which can reduce the noise caused by operation vibration to below 55 dB.

· At the same time, it can effectively avoid the contact between the host and the outside low-temperature air, and protect the stable operation of the unit in the low-temperature environment.

Under the low temperature environment in the north, the defrosting water is easy to congeal in the chassis within a short time, and long-term ice failure is easy to damage the operation of the main engine. Bolang adopts the chassis melting ice adding technology to completely remove the accumulation of frost, snow and ice in the important parts of the equipment to truly realize 360° frost-free operation.

Control parts quality, reducing installation problems: the enamel energy storage tank together with the safety valve, grundfos pumps, expansion tanks, automatic exhaust valve, temperature, pressure table, water pump, nozzle, copper tee joint, controller, electric heating rods and other 11 kinds of traditional installation need separate purchase and installation of accessories, just before they go out through scientific and rational way of connection integration into more than one include small accessories accessories.

Spec. DKFXRS-11I/R DKFXRS-11II/R DKFXRS-16I/R DKFXRS-16II/R
Nominal heating capacity at room temperature(kW) 113 10.9 16 16.8
Nominal heating at room temperature(kW) 2.56 2.65 3.9 4.1
Low-temperature
nominal heating
capacity(kW)
4.8 4.75 7.9 8.1
Low temperature nominal heating(kW) 2.1 2.15 3.38 3.5
Maximum input power(kW) 4.2 4.2 6.6 6.8
Maximum current(A) 23 8 32 12
Power Specifications(Hz) 220V ~ 50 380V 3N ~ 50 220V ~ 50 380V 3N ~ 50
Refrigerant/charge amount R22/5600g R22/5600g R22/6000g R22/6000g
noisedb(A) <62 <62 <65 <65
Water resistancekPa <55 <55 <100 <100
Anti-shock level I
waterproof level IPX4 IPX4 IPX4 IPX4
Caliber of inlet
and outlet
DN32 DN32 DN32 DN32
Unit size (mm) 1030x410x1390 1030x410x1390 1030x410x1390 1030x410x1390
Unit Weight(kg) 142 142 148 149

Air Source Air Conditioning Mini Split Heat Pump Low Temperature

Send your message to this supplier
Send Now

Air Source Air Conditioning Mini Split Heat Pump Low Temperature

Ask Latest Price
Watch Video
Brand Name :
LN
Model Number :
DKFXRS
Certification :
ISO,CE, CCC
Place of Origin :
China
MOQ :
1pc
Price :
100-10000 $/pc
Contact Supplier
video
Air Source Air Conditioning Mini Split Heat Pump Low Temperature
Air Source Air Conditioning Mini Split Heat Pump Low Temperature

Maanshan Ruika Metal Products Technology Co., Ltd.

Active Member
5 Years
anhui
Since 2002
Business Type :
Manufacturer, Exporter, Trading Company, Seller
Total Annual :
1.MILLION-2MILLION
Employee Number :
50~150
Certification Level :
Active Member
Contact Supplier
Submit Requirement