Specifications
Brand Name :
LN
Model Number :
SJKRS-28 II/C
Certification :
CE ISO CCC ROHS
Place of Origin :
China
MOQ :
Negotiable
Price :
Negotiable
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
80000pcs/year
Delivery Time :
1-30 working days
Packaging Details :
standard export package, or as per customer request
Referigeration :
CO2 R744
Application: :
Outdoor, Hotel, Commercial, Household
Compressor :
Dorin
Controller :
PLC inverter Siemens
Max Hot Water Te :
70-90 C
Working Ambient Tem :
-25C to 43C
Description

Principle Introduction of CO2 R744 Air Source Water Source Heat Pump 37kw commercial usage for hot water

The carbon dioxide heat pump includes a shell, a partition plate is horizontally arranged in the shell, a heat exchanger assembly is fixed above the partition plate, and the heat exchanger assembly includes heat exchangers arranged obliquely on both sides of the partition plate, and the heat exchanger assembly is arranged above the heat exchanger assembly. There is a fan. In the present invention, a transverse baffle is arranged inside the casing, the baffle divides the casing into upper and lower spaces, the heat exchanger assembly is installed above the baffle, and the pipeline system and the circulation system are installed in the space below the baffle , The heat exchanger assembly and the pipeline system are separated by the partition plate to avoid the convection between the heat exchanger and the pipeline system, thereby preventing the mutual influence between the two, which is conducive to the normal operation of the carbon dioxide heat pump

The adopted heat pump system involves a gas-liquid separator for a carbon dioxide heat pump system. The gas-liquid separator for carbon dioxide heat pump system includes a cylinder body with an air inlet and an air outlet. The air inlet is provided with an air inlet pipe, and the air outlet is connected with an oil return pipe. The oil return pipe is in a "U" shape. One end of the oil return pipe is communicated with the air outlet, the other end of the oil return pipe is suspended in the air and staggered from the axis of the intake pipe, and at least one oil return hole is radially arranged at the turn of the oil return pipe. The utility model has the beneficial effects of effectively realizing the gas-liquid separation function of the carbon dioxide heat pump system, the liquid that is the mixed state of lubricating oil and carbon dioxide liquid returning to the compressor smoothly at a constant flow, avoiding the occurrence of "liquid strike" or "burning cylinder" accidents and the like.

Parameters of CO2 R744 Air Source Water Source Heat Pump 37kw commercial usage for hot water

Unit type SJKRS-28 II/C SJKRS-36II/C SJKRS-55 II/C SJKRS-73 I/C SJKRS-106 IC SJKRS-I60II /C
Specifications 7.5HP 10HP 15HP 20HP 30HP 40HP
Power supply Three-phase five-wire380V/50Hz
Heating mode Direct heat/cycle type
Standard working condition Heating capacity( kw ) 27.5 36.7 55.1 72.8 10.6.5 155.1
Input Power(kW) 6.1 8.2 13.7 16.1 23.6 34.5
COP 4.5 4.5 4.5 4.5 4.5 4.5
Hot Water flow(m³/h) 0.59 0.79 1.18 1.56 2.29 3.33
High temperature condition Heating capacity kw ) 23.9 28.5 51.5 59.5 89 13.1.5
Input Power(kW) 7.5 8.9 16.1 18.6 27.8 41.1
COP 3.2 3.2 3.2 3.2 3.2 3.2
Hot Water flow(m³/h) 0.27 0.33 0.59 0.68 1.02 1.51
Low temperature condition Heating capacity( kw ) 17.3 21.4 34.8 41.5 62.2 94.5
Input Power(kW) 6.2 7.6 12.4 14.8 22.2 33.8
COP 2.8 2.8 2.8 2.8 2.8 2.8
Hot Water flow(m³/h) 0.32 0.4 0.65 0.78 1.16 1.77
Component Information Size of water pipe joint DN20 DN25 DN32 DN40
Water heat exchanger Plate or sleeve heat exchanger
Air Heat Exchanger Aluminum Fin for copper tube
compressor type Semi-closed reciprocating
Operation Panel Color touch screen
Maximum outlet temperature(℃) 90℃
Refrigerants R744 (CO2 )
Design pressure(MPa) High side 15, low side 8
Dimensions (length, width and height mm) 1450x950x1450 1600x950x1500 1850x1150x1900 2050x1150x1950 2670x1410x2150 2290x2270x1980
Noise (dB) 56 59 62 67 70 70
Weight(kg) 550 660 780 860 1180 221360
SCOPE of use Feed water temperature(℃) 5~ 40
Feed water pressure 0.05~ 0.4
Effluent temperature(℃) 55~ 90
Maximum flow 1.2 1.5 2.4 3.2 4.9 6.5
Ambient temperature(℃) ’-20~43

CO2 R744 Air Source Water Source Heat Pump 37kw Commercial For Hot Water

CO2 R744 Air Source Water Source Heat Pump 37kw Commercial For Hot Water

Send your message to this supplier
Send Now

CO2 R744 Air Source Water Source Heat Pump 37kw Commercial For Hot Water

Ask Latest Price
Watch Video
Brand Name :
LN
Model Number :
SJKRS-28 II/C
Certification :
CE ISO CCC ROHS
Place of Origin :
China
MOQ :
Negotiable
Price :
Negotiable
Contact Supplier
video
CO2 R744 Air Source Water Source Heat Pump 37kw Commercial For Hot Water
CO2 R744 Air Source Water Source Heat Pump 37kw Commercial For Hot Water
CO2 R744 Air Source Water Source Heat Pump 37kw Commercial For Hot Water

Maanshan Ruika Metal Products Technology Co., Ltd.

Site Member
5 Years
anhui
Since 2002
Business Type :
Manufacturer, Exporter, Trading Company, Seller
Total Annual :
1.MILLION-2MILLION
Employee Number :
50~150
Certification Level :
Site Member
Contact Supplier
Submit Requirement