Description:
HUIYUAN's Air Blown Micro Cables, also known as air blowing fiber are smaller diameter cable with 200um G657A1 compared with normal micro cable. The loose tubes are made of high modulus plastics (PBT) and filled with a water resistant filling gel. Loose tubes are stranded around non-metallic central strength member (FRP). Nylon is extruded as outer sheath.
Features:
Small volume, light weight, high fiber density, save duct resources
Low friction, high air blowing efficiency
All dielectric, anti-lightning, anti-electromagnetic interference
Easy maintenance, easy upgrading
All section water blocking
Excellent transmission, mechanical and environmental performance
Standards:
The optical fiber cable shall comply with the requirements of this specification and generally meet or better latest standards:
ITU-T G.650: Definitions and test methods for linear, deterministic attributes of single-mode fiber and cable
ITU-T G.657: Characteristics of a bending loss insensitive single mode optical fibre and cable for the access network
IEC 60794-1-2: Optical Fiber Cables, Part 2, Generic Specifications-Basic optical cable test procedures
IEC 60794-1-21: Optical fiber cables, Part 1-21, Generic specification - Basic optical cable test procedures - Mechanical tests methods
IEC 60794-1-22: Optical fiber cables, Part 1-22, Generic specification - Basic optical cable test procedures - Environmental test methods
IEC 60794-5-10: Optical fiber cables – Part 5.10: Family specification for outdoor micro-duct optical fiber cables, micro-ducts and protected micro-ducts for installation by blowing
Cable structure:
Technical details:
Fiber count | 12 | 24 | 36 | 48 | 60 | 72 | 96 | 144 | 288 | |
Loose tube | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 6 | 24 | |
Filler | 5 | 4 | 3 | 2 | 1 | 0 | 0 | 0 | 0 | |
Fiber/tube | 12 | 24 | 12 | |||||||
Water blocking | FRP or PE Lining | Water blocking yarn | ||||||||
Cable core | Water blocking yarn | |||||||||
Sheath thickness | Nominal: 0.45mm, Average: 0.4mm, Minimum: 0.35mm | |||||||||
Cable diameter | 4.4±0.2mm | 5.3±0.2mm | 6.0±0.2mm | 7.9±0.2mm | ||||||
Weight | 19kg/km | 28kg/km | 33kg/km | 60kg/km | ||||||
Max tensile strength | 200N | 500N | 500N | 1000N | ||||||
Max crushing resistance | 500N/100mm | 700N/100mm | ||||||||
Min bending radius - static | 12*cable diameter | |||||||||
Min bending radius - dynamic | 20*cable diameter | |||||||||
Attenuation | 0.35dB/km max @1310nm 0.22dB/km max @1550nm | |||||||||
Temperature | Storage -40 to +70℃; Installation -10 to +40℃; Operation -40 to +70℃ | |||||||||
Cable service life | 25 years |
Fiber details:
Characteristics | Specified Values | Units | ||
Mode field diameter | at 1310nm | 9.0±0.4 | µm | |
Attenuation coefficient | at 1310nm | ≤0.35 | dB/km | |
at 1550nm | ≤0.22 | dB/km | ||
Zero dispersion wavelength ( λ0) | 1300 to 1324 | nm | ||
Max zero dispersion slope (S0max) | ≤0.092 | ps/(nm2·km) | ||
Cut-off wavelength (λcc) | ≤1260 | nm | ||
Cladding diameter | 125.0±0.05 | µm | ||
Cladding non-circularity | ≤0.7 | % | ||
Coating diameter | 190.0±5.0 | µm | ||
Coating-cladding concentricity error | ≤12.0 | µm | ||
Core-cladding concentricity error | ≤0.5 | µm | ||
Curling | ≥4 | m | ||
Proof stress | ≥0.69 | GPa | ||
Coating strip force | Average value | 1.0-5.0 | N | |
Peak value | 1.3-8.9 | N | ||
Macro bending loss | Ф30mm, 10 circles | at 1550nm | ≤0.25 | dB |
Ф30mm, 10 circles | at 1625nm | ≤1.00 | dB | |
Ф20mm, 1 circles | at 1550nm | ≤0.75 | dB | |
Ф20mm, 1 circles | at 1625nm | ≤1.50 | dB |
Blowing performance:
Blowing tools | Blowing distance | ||
Plumettaz: PR-140, MiniJet-400 etc. Air pressure: 10 to 15bar | Fiber count | Microduct size 10/8mm | Microduct size 12/10mm |
12 to 72f | ≥1500m | - | |
96f | ≥1500m | - | |
144f | ≥1500m | - | |
288f | - | ≥1500m |
Environment performance:
Item | Testing method | Testing results |
Temperature cycling | IEC 60794-1-22-F1 | Allowable additional attenuation (1550nm) |
Temperature range -30℃ to +70℃ | ||
≤0.10 dB/km, reversible | ||
Water penetration | IEC 60794-1-22-F5B | Water column: 1m, 3m cable, Period: 24 hours No water leak through the open end of cable |
Filling compound flow | IEC 60794-1-22-E14 | 70℃, Period: 24 hours No compound flow from the cable |
Standard drum length
2000m/drum, 4000m/drum & 6000m/drum
Fiber color: (Support customized color)
No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Black | Yellow | Purple | Pink | Aqua |
No. | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Natural | Yellow | Purple | Pink | Aqua |
I | I | I | I | I | I | I | I | I | I | I | I |
Loose tube color: (Support customized color)
No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Black | Yellow | Purple | Pink | Aqua |
No. | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Natural | Yellow | Purple | Pink | Aqua |
Cable text print: (Support customized text)
HYOC GYCFT4 12 to 288 200um G657A1 [Drum No.] [Month-Year] [Meter marking]
Packing details:
Fiber Count | Length (m/drum) | Drum size (mm) | Gross weight (kg/drum) |
12 to 72f | 2000m/drum | 600*600*450mm | 70 |
4000m/drum | 700*700*450mm | 115 | |
96f | 2000m/drum | 600*600*450mm | 90 |
4000m/drum | 700*700*570mm | 150 | |
144f | 2000m/drum | 700*700*570mm | 100 |
4000m/drum | 800*800*570mm | 170 | |
288f | 2000m/drum | 800*800*570mm | 160 |
4000m/drum | 900*900*750mm | 300 |
at 1550nm |