Description:
HUIYUAN's Air Blown Micro Cables, also known as air blowing fiber are small diameter cable with light weight and high fiber density. Optical fibres are housed in loose tubes that are made of high-modulus plastic and filled with tube filling compound. The tubes (and fillers) are stranded around a non-metallic central strength member andsurrounded with dry water-blocking material to form a cable core. An extremely thin outer nylon sheath is extruded outside the core to enhance blowing performance.
Features:
Small size and light weight
Tube filling compound providing key protection for fibres
High fibre density, allowing full use of duct holes
Allowing to blow by phases to reduce initial investment
High blowing speed up to 50m/min, and long blowing distance up to 1000m
Allowing to blow out and replace with new cables to keep technical superiority
Avoiding destructive excavations and no need to pay high fees for deploying permission, applicable for constructions in crowded metropolitan area networks
Allowing to cut micro ducts anywhere anytime for branch without influences on other cables, saving manholes, hand holes and cable joints
Standards:
The optical fiber cable shall comply with the requirements of this specification and generally meet or better latest standards:
ITU-T G.650: Definitions and test methods for linear, deterministic attributes of single-mode fiber and cable
ITU-T G.657: Characteristics of a bending loss insensitive single mode optical fibre and cable for the access network
IEC 60794-1-2: Optical Fiber Cables, Part 2, Generic Specifications-Basic optical cable test procedures
IEC 60794-1-21: Optical fiber cables, Part 1-21, Generic specification - Basic optical cable test procedures - Mechanical tests methods
IEC 60794-1-22: Optical fiber cables, Part 1-22, Generic specification - Basic optical cable test procedures - Environmental test methods
IEC 60794-5-10: Optical fiber cables – Part 5.10: Family specification for outdoor micro-duct optical fiber cables, micro-ducts and protected micro-ducts for installation by blowing
Cable structure:
Technical details:
Fiber count | 12 | 24 | 36 | 48 | 60 | 72 | 96 | 144 | |
Loose tube | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 12 | |
Filler | 5 | 4 | 3 | 2 | 1 | 0 | 0 | 0 | |
Fiber/tube | 12 | ||||||||
Water blocking | FRP or PE Lining | Water blocking yarn | |||||||
Cable core | Water blocking yarn | ||||||||
Sheath thickness | Nominal: 0.45mm, Average: 0.4mm, Minimum: 0.35mm | ||||||||
Cable diameter | 5.5±0.2mm | 6.3±0.2mm | 7.8±0.2mm | ||||||
Weight | 27kg/km | 40kg/km | 55kg/km | ||||||
Max tensile strength | 500N | 1000N | 1000N | ||||||
Max crushing resistance | 800N/100mm | ||||||||
Min bending radius - static | 12*cable diameter | ||||||||
Min bending radius - dynamic | 20*cable diameter | ||||||||
Attenuation | 0.35dB/km max @1310nm 0.22dB/km max @1550nm | ||||||||
Temperature | Storage -40 to +70℃; Installation -10 to +40℃; Operation -40 to +70℃ | ||||||||
Cable service life | 25 years |
Fiber details:
Characteristics | Specified Values | Units | ||
Mode field diameter | at 1310nm | 9.2±0.4 | µm | |
at 1550nm | 10.4±0.6 | µm | ||
Attenuation coefficient | at 1310nm | ≤0.40 | dB/km | |
at 1550nm | ≤0.30 | dB/km | ||
Zero dispersion wavelength ( λ0) | 1300 to 1324 | nm | ||
Max zero dispersion slope (S0max) | ≤0.092 | ps/(nm2·km) | ||
Cut-off wavelength (λcc) | ≤1260 | nm | ||
Cladding diameter | 125.0±1.0 | µm | ||
Cladding non-circularity | ≤1.0 | % | ||
Coating diameter | 245.0±10.0 | µm | ||
Coating-cladding concentricity error | ≤12.0 | µm | ||
Coating non-circularity | ≤6.0 | % | ||
Core-cladding concentricity error | ≤0.8 | µm | ||
Curling | ≥4 | m | ||
Proof stress | ≥0.69 | GPa | ||
Coating strip force | Average value | 1.0-5.0 | N | |
Peak value | 1.3-8.9 | N | ||
Macro bending loss | Ф60mm, 100 circles | at 1550nm | ≤0.05 | dB |
Ф32mm, 1 circles | at 1550nm | ≤0.05 | dB |
Blowing performance:
Blowing tools | Blowing distance | ||
Plumettaz: PR-140, MiniJet-400 etc. Air pressure: 15bar | Fiber count | Microduct size 10/8mm | Microduct size 12/10mm |
12 to 72f | ≥2000m | ≥2500m | |
96f | ≥2000m | ≥2500m | |
144f | - | ≥1500m |
Standard drum length
2000m/drum, 4000m/drum & 6000m/drum
Fiber color: (Support customized color)
No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Black | Yellow | Purple | Pink | Aqua |
No. | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Natural | Yellow | Purple | Pink | Aqua |
I | I | I | I | I | I | I | I | I | I | I | I |
Loose tube color: (Support customized color)
No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Black | Yellow | Purple | Pink | Aqua |
No. | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Natural | Yellow | Purple | Pink | Aqua |
I | I | I | I | I | I | I | I | I | I | I | I |
Cable text print: (Support customized text)
HYOC GYCFT4 12 to 288 G652D [Drum No.] [Month-Year] [Meter marking]
Packing details:
Fiber Count | Length (m/drum) | Drum size (mm) | Gross weight (kg/drum) |
12 to 72f | 2000m/drum | 600*600*450mm | 95 |
4000m/drum | 700*700*570mm | 150 | |
6000m/drum | 800*800*570mm | 210 | |
96f | 2000m/drum | 600*600*570mm | 120 |
4000m/drum | 800*800*570mm | 220 | |
6000m/drum | 800*800*760mm | 300 |