Blown In Fiber FTTX 4 Core G652D EPFU Blown Fiber Optic Cable
Description
HYOC Enhanced Performance Fibre Units (EPFU) are designed for air blown applications and are optimised for installation within our microducts. The fibres are sheltered by a soft acrylate layer. This layer is coated with a strengthened hard HDPE layer and a low-friction coating to improve blowing performance. The acrylate layer is easy to remove.
Technical specification:
Optical fiber | G652D | |
Fibre type | Single mode | |
Number of fiber | 4 fiber | |
Outer sheath material | Polyethylene | |
Cable nominal diameter(±0.05mm) | 1.15mm | |
Cable approx. weight (kg/km) | 1 | |
Max. tensile strength | Short time | 9N |
Max. crush resistance | Short time | 100N/100mm |
Minimum Bending radius | Dynamic | 20 X cable diameter |
Static | 10 X cable diameter | |
Temperature range | Installation | -10℃ to +40℃ |
Storage | -20℃ to +60℃ | |
Operation | -20℃ to +60℃ |
Blowing test:
Blowing test equipment | PLUMETTAZ: UltimaZ | |
Standard duct | 5.0/3.5mm | |
Pressure | 10 bar | |
Typical blowing distance | 4 Fibres | 1000m |
Typical blowing time | 4 Fibres | 35 min |
Fiber specification:
Characteristics | Specified Values | Units | |
Mode field diameter | at 1310nm | 9.2±0.4 | µm |
at 1550nm | 10.4 ± 0.6 | mm | |
Attenuation coefficient | at 1310nm | ≤0.40 | dB/km |
at 1550nm | ≤0.30 | dB/km | |
Cladding diameter | 125.0±1.0 | µm | |
Cladding non-circularity | ≤1.0 | % | |
Coating diameter | 245.0±10.0 | µm | |
Coating-cladding concentricity error | ≤12.0 | µm | |
Coating non-circularity | ≤6.0 | % | |
Core-cladding concentricity error | ≤0.8 | µm |
Cable structure:
1. G652D fiber 2. Resin 3. Filler fibers 4. Groove 5. HDPE sheath
Standards:
ITU-T G.652.D | Characteristics of a single-mode optical fiber and cable |
ANSI/TIA/EIA 598-C | Optical Fibre Cable Colour Coding |
IEC 60794-1-2:2017 | Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance |
IEC 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
Standard drum length
2000m/drum, 4000m/drum & 6000m/drum
Fiber color: (Support customized color)
No. | 1 | 2 | 3 | 4 |
Color | Blue | Orange | Green | Brown |
Cable text print: (Support customized text)
HYOC FU 4F G652D [Drum No.] [Month-Year] [Meter marking]
Packing details:
Fiber Count | Length (m/drum) | Packing size (mm) | Gross weight (kg/drum) |
2 Fibers | 2000m/drum | 510*510*200mm | 8kg |
4000m/drum | 510*510*200mm | 10kg | |
6000m/drum | 510*510*300mm | 12kg |
Factory & production line