Kevlar Aramid Yarn Strengthen ADSS Fiber Cable G652D Single Mode 2 Core
Description:
HUIYUAN's ADSS fiber cable is designed to be strong enough to allow lengths of up to 700 meters to be installed between support towers. The cable is made of non-metallic material and self-supporting with the aerial power transmission line. The tension resistance material is aramid yarn with high elasticity modules. And optimizing structure can deploy the weight of the cable and its mechanical and physical properties appropriately and minimize the load on the tower.
Features:
1. Small outer diameter and high tensile resistance
2. High modular of elasticity
3. Small thermal expansion coefficient
4. Excellent flexibility capability
Standards:
The ADSS fiber cable shall comply with the requirements of this specification and generally meet or better latest standards:
ITU-T G.650: Definitions and test methods for linear, deterministic attributes of single-mode fiber and cable
ITU-T G.657: Characteristics of a bending loss insensitive single mode optical fibre and cable for the access network
IEC 60794-1-2: Optical Fiber Cables, Part 2, Generic Specifications-Basic optical cable test procedures
IEC 60794-1-21: Optical fiber cables, Part 1-21, Generic specification - Basic optical cable test procedures - Mechanical tests methods
IEC 60794-1-22: Optical fiber cables, Part 1-22, Generic specification - Basic optical cable test procedures - Environmental test methods
IEC 60794-5-10: Optical fiber cables – Part 5.10: Family specification for outdoor micro-duct optical fiber cables, micro-ducts and protected micro-ducts for installation by blowing
Cable structure:
Technical details:
Product Name | ADSS Fiber Cable G652D Single Mode 2 Core | |
Items | Condition | Value |
Fiber count | - | 2 to 144 core |
Max. tensile strength (N) | Short term | As per requested |
Long term | As per requested | |
Max. crush strength (N/mm) | Short term | 3000 /2200 |
Long term | 1000 | |
Min. bend radius (mm) | Statics | 12.5 * cable diameter |
Dynamics | 25 * cable diameter | |
Drum length (KM) | - | 2 to 4 |
Working temperature (℃) | - | -40 to +60 |
Contact us for more details |
Fiber details:
Characteristics | Specified Values | Units | ||
Mode field diameter | at 1310nm | 9.2±0.4 | µm | |
at 1550nm | 10.4±0.6 | µm | ||
Attenuation coefficient | at 1310nm | ≤0.35 | dB/km | |
at 1550nm | ≤0.22 | dB/km | ||
Zero dispersion wavelength ( λ0) | 1300 to 1324 | nm | ||
Max zero dispersion slope (S0max) | ≤0.092 | ps/(nm2·km) | ||
Cut-off wavelength (λcc) | ≤1260 | nm | ||
Cladding diameter | 125.0±1.0 | µm | ||
Cladding non-circularity | ≤1 | % | ||
Coating diameter | 245.0±10.0 | µm | ||
Coating-cladding concentricity error | ≤12.0 | µm | ||
Core-cladding concentricity error | ≤0.8 | µm | ||
Curling | ≥4 | m | ||
Proof stress | ≥0.69 | GPa | ||
Coating strip force | Average value | 1.0-5.0 | N | |
Peak value | 1.3-8.9 | N | ||
Macro bending loss | Ф60mm, 100 circles | at 1550nm | ≤0.05 | dB |
Ф32mm, 1 circles | at 1550nm | ≤0.05 | dB |
Standard drum length (support customized drum length)
2000m/drum, 4000m/drum & 6000m/drum
Fiber color: (Support customized color)
No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Black | Yellow | Purple | Pink | Aqua |
No. | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Natural | Yellow | Purple | Pink | Aqua |
I | I | I | I | I | I | I | I | I | I | I | I |
Loose tube color: (Support customized color)
No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Black | Yellow | Purple | Pink | Aqua |
No. | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Color | Blue | Orange | Green | Brown | Gray | White | Red | Natural | Yellow | Purple | Pink | Aqua |
Cable text print: (Support customized text)
HYOC ADSS 12 to 288 G652D [Drum No.] [Month-Year] [Meter marking]
Remarks:
Detail requirements need to be sent to us for cable design and price calculation. Below requirements are a must:
A, Power transmission line voltage level
B, fiber count
C, Span or tensile strength
D, weather conditions