Cleanroom Extruded Aluminum Frame H14 TOP Side Gel Seal HEPA Air Filter for GMP
Introduction:
These filters is constructed with galvanized frame,aluminum frame.
The interlock frame design with sealant in the top and tiattow flange.
Protective mesh on both sides prevent filters from damaging and blemishing.
Available in a wide range standard sizes to meet variety of demands and install space.
Individually leak test guarantee each filter be of good capacity and operate well in the system.
Pleated filter media packs enlarge the media area farthest and increase the dust holding capcity to extend the useful time.
Features:
HEPA or high efficiency particulate arresting filters capture 99.97% of airborne contaminants as small as 0.3 microns in size. The HEPA filter removes bacteria,mold spores,soot, pollens, animal hair, animal dander, dust mites, smoke particles and other allergens and lung damaging particles.
1. Frame: Galvanized sheet/ aluminum
2. Sealant: Polyurethane adhesive
3. Separator: thermosol
4. Media: fiberglass paper
5. Max. Operating Temperature: 80 C
6. Max. Operating Humidity: 80%
7.Seal: Gel seal
Application:
Clean rooms for micro component electronic manufacture & assembly
Food processing industry.
Pharmaceutical Processing
Aerospace Engineering
Genetic & Biological research
Biohazard Atmosphere
Laminar Flow Workstations
Bio Safe Hoods(Biological Safety Cabinets)
Hospital Operating Theaters & Intensive care units
Atomic Research
Pre filter stage to ULPA systems
Specification:
Customer Size is Available.
Nominal Size | Actually Size | Thickness | Screen | Rate air flow | Face Velocity | Primary Resistance |
(Feet)(W*H*D) | (mm)(W*H*D) | (mm) | (m3/h) | (m/s) | (Pa) | |
2x2 | 570x570 | 80 | Both side | 472 | 0.45 | H13 :110pa H14: 120Pa U15: 140Pa |
4x2 | 1170x570 | 80 | Both side | 1000 | 0.45 | |
2x1 | 610x305 | 80 | Both side | 258 | 0.45 | |
2x2 | 610x610 | 80 | Both side | 545 | 0.45 | |
2.5x2 | 762x610 | 80 | Both side | 687 | 0.45 | |
3x2 | 915x610 | 80 | Both side | 831 | 0.45 | |
2x2 | 570x570 | 104 | Both side | 472 | 0.45 | H13 :80pa H14: 90Pa U15: 110Pa |
4x2 | 1170x570 | 104 | Both side | 1000 | 0.45 | |
2x1 | 610x305 | 104 | Both side | 258 | 0.45 | |
2x2 | 610x610 | 104 | Both side | 545 | 0.45 | |
2.5x2 | 762x610 | 104 | Both side | 687 | 0.45 | |
3x2 | 915x610 | 104 | Both side | 831 | 0.45 |
Gel Seal HEPA Air Filter On Side | |||||||
Nominal Size | Actually Size | External size | Thickness | Screen | Rate air flow | Face Velocity | Rate Primary Resistance |
(Feet)(W*H*D) | (mm)(W*H*D) | (W+40)x(L+40) | (mm) | (m3/h) | (m/s) | (Pa) | |
2x2 | 570x570 | 610X610 | 93 | Both side | 472 | 0.45 | H13 :80pa H14: 90Pa U15: 110Pa |
4x2 | 1170x570 | 1210X610 | 93 | Both side | 1000 | 0.45 | |
2x1 | 610x305 | 660X345 | 93 | Both side | 258 | 0.45 | |
2x2 | 610x610 | 650X660 | 93 | Both side | 545 | 0.45 | |
2.5x2 | 762x610 | 802X650 | 93 | Both side | 687 | 0.45 | |
3x2 | 915x610 | 955X650 | 93 | Both side | 831 | 0.45 |