Horizontal Laminar Air Flow Cabinet/ Clean Bench/ Laminar Flow Hoods For Laboratory
Model |
|
KEL-HA |
benchtop horizontal airflow hood |
KEL-HA1 |
single person vertical airflow hood |
KEL-HA2 |
double person vertical airflow hood |
KEL-HA3 |
single person horizontal airflow hood |
KEL-HA4 |
double person horizontal airflow hood |
Application
This series laminar flow hood is the essential equipment to carry out biotechnology research and experimental, widely used in medical, college and other industries. Provide air purification for the working area.
Features:
1, Two models horizontal laminar flow and vertical laminar clean bench.
2, According to using function are desktop and vertical clean bench,single people single side(two sides) and two people single
side(two sides).
3, The working surface is made of mirror stainless steel, easy to clean, corrosion-resistant.
4, Equipped with many kinds filter to meet the customer’s purification degree requirements.
5, LED microcomputer controller, adjustable fan speed.
Model | KEL-1000 | KEL-1350 | KEL-1610 | KEL-1915 |
External size(mm) | W1000*L740*H1460 | W1350*L740*H1460 | W1610*L740*H1460 | W1915*L740*H1460 |
Internal working size(mm) | W980*L480*H610 |
W1285*L480*H610 |
W1590*L480*H610 |
W1895*L480*H610 |
Air flow(m/h) | 900 | 1200 | 1500 | 1800 |
wind velocity | 0.45m/s±20% | |||
Cleanliness class | Class 100 (ISO14644-1 International standard) | |||
Mini-pleat Hepa Filter | 99.99% @ 0.3μm | |||
Size & NO. of Hepa Filter | 915*610*69-1 |
1220*610*69-1 |
915*610*69-1 610*610*69-1 |
915*610*69-2 |
Table material | SS304 | |||
Noise | <50 dB | <50 dB | <50 dB | <50 dB |
Noise testing area | The area 20cm away from the front of clean bench and 1.2 m height. | |||
Power | AC, 220V 50/60Hz | |||
Used for NO. of people | 1 |
1-2 |
2-3 |
3-4 |
Parameters for Vertical Clean Bench:
Model | KEL-S-1000 | KEL-S-1350 | KEL-S-1640 | KEL-S1950 |
External size(mm) | W1000*L650*H1750 | W1350*L650*H1750 | W1640*L650*H1750 | W1950*L650*H1750 |
Internal working size(mm) | W820*L610*H600 |
W1270*L610*H600 |
W1560*L610*H600 |
W1870*L610*H600 |
Air flow(m/h) | 900 | 1100 | 1500 | 1800 |
wind velocity | 0.45m/s±20% | |||
Cleanliness class | Class 100 (ISO14644-1 International standard) | |||
Mini-pleat Hepa Filter | 99.99% @ 0.3μm | |||
Size & NO. of Hepa Filter | 880*570*69-1 |
1170*570*69-1 |
915*570*69-1 610*570*69-1 |
915*610*69-2 |
Table material | SS304 | |||
Noise | <50 dB | <50 dB | <50 dB | <50 dB |
Noise testing area | The area 20cm away from the front of clean bench and 1.2 m height. | |||
Power | AC, 220V 50Hz | |||
Used for NO. of people | 1 |
1-2 |
2-3 |