Specifications
Brand Name :
FIATEST
Model Number :
FI-MYO-402
Certification :
CE
Place of Origin :
China
MOQ :
N/A
Price :
negotiation
Payment Terms :
L/C, T/T
Supply Ability :
10 M tests/month
Delivery Time :
2-4 Weeks
Packaging Details :
10T/25T
Product Name :
Myoglobin Test Cassette, Quantitative determination of Myoglobin in whole blood, serum or plasma
Principle :
Fluorescence Immunoassay
Format :
Cassette
Specimen :
WB/S/P
Certificate :
CE
Reading Time :
15 minutes
Pack :
10T/25T
Storage Temperature :
4-30℃
Shelf Life :
2 Years
Cut-Off :
90 ng/mL
Linearity range :
5~200 ng/mL , R≥0.990
Description

Myoglobin Test Cassette, Quantitative determination of Myoglobin in whole blood, serum or plasma

Application:

A rapid test for measuring Myoglobin (MYO) in whole blood /serum /plasma with the use of Fiatest TM fluorescence Immunoassay Analyzer. For professional in vitro diagnostic use only.
Product Name: Myoglobin Test Cassette, Quantitative Determination Of Myoglobin In Whole Blood, Serum Or Plasma
Format: Cassette
Certificate: CE
Pack: 10T/25T
Shelf Life: 2 Years
Linearity Range: 5~200 Ng/mL , R≥0.990
Principle: Fluorescence Immunoassay
Specimen: WB/S/P
Reading Time: 15 Minutes
Storage Temperature: 4-30℃
Cut-Off: 90 Ng/mL

Description:

Myoglobin (MYO) is a heme-protein normally found in skeletal and cardiac muscle with a molecular weight of 17.8 kDa. It constitutes about 2 percent of total muscle protein and is responsible for transporting oxygen within the muscle cells.1 When the muscle cells are damaged, Myoglobin is released to the blood rapidly due to its relatively small size. Following the death of tissue associated with MI, Myoglobin is one of the first markers to rise above normal levels. The level of Myoglobin increases measurably above baseline within 2-4 hours post-infarct, peaking at 9-12 hours and returning to baseline within 24-36 hours.2,3 A number of reports suggest the measurement of Myoglobin as a diagnostic aid in confirming the absence of myocardial infarction with negative predictive values of up to 100% reported at certain time periods after onset of symptoms.

【PERFORMANCE CHARACTERISTICS】

1. Accuracy

The test deviation is ≤±15%.

2. Sensitivity

The Myoglobin Test Cassette can detect levels of Myoglobin as low as 5 ng/mL in whole blood, serum or plasma.

3. Detection range

5~200 ng/mL

4. Linearity range

5~200 ng/mL , R≥0.990

5. Precision

C.V. ≤15%

Fast Result (15 minutes)

Simple Operation (Less Training Required)

Objective (Results Read by Analyzer)

Stringent Quality Control Insure High Accuracy

User-friendly (Simple Plug & Play Operation)

High Efficiency (Both STAT Testing and Batch Testing)

How to use?

Refer to Fiatest TM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be conducted in roomtemperature.
1. Turn on the Analyzer power. Then according to the need, select “standard test” or“Quick test” mode.
2. Take out the ID card and insert it into the Analyzer ID Card Slot.
3. Serum/Plasma: Pipette 50 μL serum/plasma into the buffer tube, mix the specimen and the buffer well.
Whole blood: Transfer 75 μL whole blood into the buffer tube with pipette; mix the specimen and the buffer well.
4. Add diluted specimen with a Pipette: Pipette 85 μL diluted specimen into the sample well of the test cassette. Start the timer at the same time.
5. There are two test modes for Fiatest TM Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode. Please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyzer for details.
“Quick test” mode: After 15 minutes of adding sample, Insert the test cassette into the Analyzer, click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.
“Standard test” mode: Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time, The Analyzer will automatically countdown 15 minutes. After the countdown, the Analyzer will give the result at once.

Myoglobin Rapid Test Fluorescence Immunoassay Test

INTERPRETATION OF RESULTS

Results read by Fiatest TM Fluorescence Immunoassay Analyzer.
The result of tests for Myoglobin is calculated by Fiatest TM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyze.
Linearity range of FluroLit TM Myoglobin Test is 5~200 mg/L.
Catalogue Number Item Name Sample Test Range KIT size
FI-MYO-402 Myoglobin Test Cassette WB/S/P 5-200 ng/mL 10T/25T
Send your message to this supplier
Send Now

Myoglobin Rapid Test Fluorescence Immunoassay Test

Ask Latest Price
Brand Name :
FIATEST
Model Number :
FI-MYO-402
Certification :
CE
Place of Origin :
China
MOQ :
N/A
Price :
negotiation
Contact Supplier
Myoglobin Rapid Test Fluorescence Immunoassay Test

Hangzhou AllTest Biotech CO.,LTD

Verified Supplier
4 Years
zhejiang, hangzhou
Since 2009
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
80000000-100000000
Employee Number :
1000~9999
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement