1x4 Mechanical Optical Switch SM 1310nm 1550nm Low Insertion Loss
1x4 Mechanical Optical Switch SM 1310/1550nm 1m 900um FC/APC
Description
1xN mechanical fiber optic switch manufactured by ANC International Co., Limited connects optical channels by redirecting an incoming optical signal into a selected output fiber. This is achieved using a patent pending opto-mechanical configuration and activated via an electrical control signal. The mechanical operation offers ultra-high reliability and fast switching speed as well as bi-directional performance. 1×4 Optical switch is a kind of functional component, with the ability of switching optical route. In optical fiber transmission system, it is used for multi-channel fiber monitoring, multi light source/ detector selection, and optical fiber path protection etc. Besides, it is also used in optical fiber test system for optical fiber and its component test, outdoor cable test and multi-spot optical sensors monitoring system.
Specification
Up to 128 channels
Low Insertion Loss
Parellel interface
Highly Stable and Reliable
Epoxy-Free Optical Path
Modularized Design
Single mode and Multi-mode
Application Of Fiber Optic Splitter
PLC splitter was widely used in all kinds of optical network solutions , such as Security Monitoring, Optical Communication, Network Construction, CATV and Pon network.
Technical Data
Parameters | Unit | AC-OSW1×N | |||
Insertion Loss | dB | 1 < N ≤ 32 | 32 < N ≤ 64 | 64 < N ≤ 128 | |
Type: 0.8 Max: 1.0 | Type: 1.0 Max: 1.2 | Type: 1.1 Max: 1.3 | |||
Wavelength Range | nm | 850±40 / 1300±40,1550 | 1260 ~ 1650 | ||
Test Wavelength | nm | 850 / 1300,1550 | 1310 / 1550 | ||
Return Loss | dB | MM ≥ 30 SM ≥ 50 | |||
Crosstalk | dB | ≥ 55 | |||
PDL | dB | ≤ 0.05 | |||
WDL | dB | ≤ 0.25 | |||
TDL | dB | ≤ 0.25 | |||
ER | dB | ≥ 18(PM switch) | |||
Repeatability | dB | ≤ ±0.05 | |||
Durability | Cycles | ≥ 10 Million | |||
Switching Time | ms | ≤ 15(Sequence switch time of adjacent channel) | |||
Optical Power | mW | ≤500 | |||
Operating Temperature | ℃ | -10 ~ +70 | |||
Storage Temperature | ℃ | -40 ~ +85 | |||
Relative Humidity | % | 5 ~ 95 | |||
Dimension | mm | 135×60×35 (N≤4) | 135×60×35 (N≤12) | 135×60×35(N≤20) | |
135×60×38 (N≤32) | 165×72×65 (N≤64) | 165×130×130 (N≤128) |
Pin Configurations
DB-9 male connector (max.1×16)
Pin No. | Signal Name | I / O | Description |
1 | D0 | Input | TTL, Channel selection bit 0 |
2 | D1 | Input | TTL, Channel selection bit 1 |
3 | D2 | Input | TTL, Channel selection bit 2 |
4 | D3 | Input | TTL, Channel selection bit 3 |
5 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
6 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
7 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
8 | GND | Input | Ground |
9 | +5VDC | Input | 5.0±5% VDC Power Supply (max 800mA) |
Optical Route
Ordering Information
N | A | B | C | D | E | F |
Channel | Fiber Type | Test Wavelength | Tube Type | Fiber Length (Include connector) | Connector | Dimension |
1 ~ 128 | SM: SM, 9/125 M5: MM, 50/125 M6: MM, 62.5/125 X: Others | 85: 850nm 13: 1310nm 15: 1550nm 1315:1310/1550nm X:Others | 9: 900um 2: 2.0mm 3: 3.0mm X: Others | 05: 0.5m±5cm 10: 1.0m±5cm 15: 1.5m±5cm X: Others | OO:None FP: FC/PC FA: FC/APC SP: SC/PC SA: SC/APC STP: ST/PC STA: ST/APC LP: LC/PC LA: LC/APC X: Others | 01: 135×60×35-DB9 02: 135×60×35-DB9-F 03: 135×60×35-DB15 04: 135×60×35-DB15-F 05: 135×60×38-DB15 06: 135×60×38-DB15-F 07: 165×72×65-DB15 08: 165×72×65-DB15-F 09: 165×130×130-DB25 10: 165×130×130-DB25-F 11: 140×77.5×35-DB15-C 12: 140×77.5×35-DB15-C-F 13: 140×77.5×64-DB15-C 14: 140×77.5×64-DB15-C-F X: Others |
Product Picture