Test Item | Parameter | Unit | Remarks | |||
working voltage | 28 | V | 24-30V | |||
transfer efficiency | ≥42% | % | @100W typical | |||
Controlled output power | 10W~100W | W | The Software sets the power level | |||
The ALC power adjustment range | ≥30 | dB | Pressure control attenuation | |||
gain | 50±1.0 | dB | ||||
Intra-band fluctuations | ≤2.5 | dB | peak-to-peak value | |||
stray launch | Work within the belt | ≤-15dBm/1MHz | dBm | Center frequency plus CW signal to the maximum output power measurement | ||
work out-off-band | 9KHz~1GHz | No noise above normal | dBm | |||
1G~12.75GHz | dBm | |||||
Maximum allowable input power | ≥+10dBm | dBm | For 1min without damage | |||
Input voltage standing wave ratio | ≤1.35 | Add + 28V, standard network output-10 dBm | ||||
Output voltage standing wave ratio | ≤1.30 | Without power supply, the output of the standard grid is-10 dBm | ||||
≤1.35 | Power-up, bidirectional coupler test | |||||
High and low temperature test | Working environment temperature: (ºC) | -10~+65 | ºC | Low temperature can start and monitoring is normal | ||
gain stability | ±1.5 @-40ºC~+65ºC | dB | ||||
Power stability | ±1 @-40ºC~+65ºC | dB | ||||
Power supply requirements | ≥8A @+28V dc ; | Continuous W output 100W | ||||
Power supply interface, monitoring interface RS485 | 7W2 | Public head | ||||
RF output connector | N-F connect | |||||
LCD liquid crystal display | Display the frequency, power, and switch status |
Quantity (sets) | 1-50 | > 50 |
Lead time (days) | less than 7 days | 7-14days |