Specifications
Brand Name :
KISSH
Model Number :
K903-10
Certification :
CE
Place of Origin :
CHINA
MOQ :
1000 tests
Price :
Negotiable
Payment Terms :
T/T
Supply Ability :
1,000,000 tests per day
Delivery Time :
Within 7 days
Packaging Details :
1 Test/Kit, 5 Tests/Kit, 10 Tests/Kit, 20 Tests/Kit
Namee :
SARS-CoV-2 Antigen Test Kit(Immunofluorescence)
Application :
In vitro qualitative detection of of the nucleocapsid protein antigen from SARS-CoV-2 in nasopharyngeal (NP), nasal swab and saliva specimens
Specimen :
Nasopharyngeal (NP) and Nasal swab,Saliva,Oropharyngeal (OP) swab
Methodology :
Immunofluorescence
Storage Condition :
2-30℃
Function :
SARS-CoV-2 Detection
Description

SARS-CoV-2 Antigen Test Kit(Immunofluorescence)

Product Information

Keywords

SARS-CoV-2 Antigen Test Kit(Immunofluorescence)

Main Composition

Test Cassette individually foil pouched with a desiccant, Sample Tube, with cap and antigen extraction buffer,Sampling swab, Instruction for use

Sampling

Nasopharyngeal (NP) and Nasal swab,Saliva,Oropharyngeal (OP) swab

Usage/

Qualitative detection of the nucleocapsid protein antigen from SARS-CoV-2 in nasopharyngeal (NP), nasal swab and saliva specimens

Package

10 Test/Kit

Brand

KISSH

Shelf-life

12 months

Test procedure

Perform the test only when the reagent has equilibrated to room temperature (18 ℃~26 ℃ ) to avoid affecting the accuracy of the experimental results.

1. Instrument preparation: ① Turn on the power of the fluorescence analyzer, select the detection mode (quick test/standard test); ② Read the reagent ID chip; ③ Select the sample type and test items; ④ The specific operation of the instrument is performed in accordance with the instruction manual of the corresponding model instrument.

2. Take the sample to be tested and the required reagents out of storage conditions and equilibrate to room temperature.

3. Unpack the aluminum foil pouch, place the test card horizontally on the table and mark it.

4. Place the sample tube on the workbench.Insert the collected swab into the sample tube,rotate the swab for about 10 seconds, and press the swab head against the tube wall to release antigen in the swab. Squeeze the swab over the head to remove the swab so as to remove as much liquid as possible from the swab. Dispose of swabs according to biohazard wasted disposal method.

5. Install the dropper cap onto the smaple tube, put two drops ofthe extraction solution into the sample well and startt he timer.

6.Test

① Standard test:

After the sample is added, insert the test card into the instrument and click “start test”. The instrument automatically counts the time. After the reaction countdown of 15 minutes is over, the instrument automatically performs the test, and records, reads and prints the test results.

② Quick test:

After adding the sample, time 15 minutes with a timer. When the time is up, insert the test card into the instrument, and click "Start Test". The instrument automatically performs the test, and records, reads and prints the test results.

If the test card fails to be tested in time within 15~20 minutes, it will be deemed as invalid test, and the sample need to be retested with a new test card.

Send your message to this supplier
Send Now

SARS-CoV-2 Saliva Antigen Rapid Test Kit In Vitro Qualitative Detection

Ask Latest Price
Brand Name :
KISSH
Model Number :
K903-10
Certification :
CE
Place of Origin :
CHINA
MOQ :
1000 tests
Price :
Negotiable
Contact Supplier
SARS-CoV-2 Saliva Antigen Rapid Test Kit In Vitro Qualitative Detection

Shenzhen Kisshealth Biotechnology Co., Ltd

Active Member
4 Years
shenzhen
Since 2018
Business Type :
Manufacturer
Total Annual :
10,000,000-30,000,000
Employee Number :
50~150
Certification Level :
Active Member
Contact Supplier
Submit Requirement