Sulfonamides Residues (SAs) Rapid Test Strips for Tissue 96 Tests/Kit
1. Specifications:
8 strips/bottle, 12 bottles/kit
2. Brief
This product is used for testing Sulfonamides residue in tissue(fish, shrimp, crab, poultry, livestock etc.) sample. The total test time only need 15~20 min, fast with high sensitivity.
3. Detection limit
Sulfadiazine (SD or SDZ) | 3-5ppb |
Sulfamerazine (SM1) | 3-5ppb |
Sulfamonomethoxine (SMM) | 1-2ppb |
Sulfadimoxine (SDM2) | 12-15ppb |
Sulfabenzoyl (SML) | 10-15ppb |
Sulfamethoxypyridazine (SMP) | 15-20ppb |
Sulfaquinoxaline(SQX) | 10-15ppb |
Sulfamethoxazole (SMZ) | 30-50 ppb |
Sulfanethazine(SM2) | 10-15ppb |
Sulfamethoxydiazine(SMD) | 1-2ppb |
Sulfadimethoxine(SDM) | 3-5ppb |
Sulfafurazole(SIZ) | 45-50ppb |
Sulfisomidine | 8-10ppb |
Sulfamethizole (SMT) | 45-50ppb |
Sulfaclozine (Esb3) | 8-10ppb |
Sulfachloropyridazine (SCPA) | 25-30ppb |
4. Principle
TheSulfonamides rapid test dipstick is based on competitive inhibition immuno-chromatographic principle. In the flow process, Sulfonamides in the sample combined with Sulfonamides specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Sulfonamides-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the concentration of Sulfonamides residue in sample is equal to or higher than detection limit, T line is obviously lighter than C line or T line has no color, the result is Positive.When the sample has no Sulfonamides residue or concentration lower than detection limit, T line is darker than C line, the result is Negative; No matter whether there is Sulfonamides residue in sample, C line will appear, it means the test is valid.
5. Contents
1 | Sulfonamides test strips | 8 strips/bottle, 12 bottles |
2 | Red Micro-well | 8 wells/bottle, 12 bottles |
3 | Manual | 1 piece |
4 | Desiccant | 2 pieces/bag |
5 | Sample extract A 10X | 1 bottle |
6 | Sample extract B | 1 bottle |
6. Solution preparation
Dilute Sample extract A 10X with deionized water at 1:9: 1 partSample extract A 10X + 9 parts deionized water.
7. Sample preparation
Tissue(fish and chicken)
Take 3±0.05g homogenized tissue sample, add 3ml Sample extract A, shake for 2min; then add 300ul Sample extract B, shake for 1min; centrifuge at 4000rpm for 5min, take up-layer clear liquid to test.
Tissue(shrimp)
Take 3±0.05g homogenized tissue sample, add 3ml Sample extract A, shake for 2min; then add240ul Sample extract B, shake for 1min; centrifuge at 4000rpm for 5min, take up-layer clear liquid to test.
8. Operation procedures
8.1 Return sealed test strips, micro-wells and sample into room temperature.
8.2 Take necessary strips and micro-wells on desk, use it in 1 hour.
8.3 Take 200ul of the test samples into the micro-wells, then repeatedly pump and suck for 5-6 times, mix the sample with the reagent in the micro-wells completely.
8.4 Incubate for 3min at room temperature (20-25℃), then insert the test dipsticks into the micro-wells with the "MAX" end fully dipped in to the mixture solution.
8.5 React at room temperature (20-25℃) for 5min, take out the test strips and read the result.
9. Test Result Interpretation
9.1 Negative: T line is darker than C line, or T line has same color with C line. It means there is no Sulfonamides residue in sample or the residue is lower than detection limit.
9.2 Positive: T line is obviously lighter than C line or T line is invisible. It means the Sulfonamides residue is equal to or higher than detection limit.
9.3 Invalidation: C line isn’t seen wine red. It means the test card is out of efficacy, out of date or improper operation. Please run the test again using another package. If the invalid tests keep happening.
10. Specificity
There is no cross reaction with Streptomycin, Tetracycline and Quinolone etc..
11. Precautions
1) The test strips can be used only once at room temperature, do not use strips out of expiry date.
2) Do not touch the white membrane surface in the middle of test strip, avoid sunlight and fan blowing directly.
3) Tap water, distilled water and deionized water can not be as negative control.
12. Storage and expiry date
Storage: Store at 2-8 ℃ in dark, sealed, dry place, no frozen.
Expiry date: 12 months; date of production is on box.
Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In the event of the epidemic and other external factors, there may be delays in shipping)
Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.
Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.
Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.
Q5: What is the payment method?
A5: We receive payment by T/T.
Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.