Specifications
Brand Name :
Green Spring
Model Number :
LSY-10002
Certification :
ISO13485,ISO9001
Place of Origin :
China
MOQ :
1kit
Price :
Negotiable
Payment Terms :
T/T
Supply Ability :
100000 tests per day
Delivery Time :
7~14days
Sample Performance :
Fish,Shrimp, Chicken,Liver,Egg,Milk
Sensitivity (ppb) :
0.01 ppb
Specification :
96 Wells/Kit
Key words :
Nitrofuran AOZ ELISA Kit
Type :
Diagnostic ELISA Kit
Size :
16.7x11.5x10.2cm
Storage :
Store at 2-8°C,not frozen
Instrument classification :
Class II
Description

Nitrofuran AOZ Diagnostic ELISA Kit for Fish 96 Wells/Kit Sensitivity 0.01

1. Nitrofuran AOZ Diagnostic ELISA Kit Principle

This test kit is based on the competitive enzyme immunoassay for the detection of AOZ in the sample. The coupling antigens are pre-coated on the micro-well stripes. The AOZ in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-AOZ antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the AOZ in it. This value is compared to the standard curve and the AOZ concentration is subsequently obtained.

2. Technical specifications


Sensitivity: 0.01ppb
Incubation Temperature: 25℃
Incubation Time: 30min~15min
Detection limit
Tissue, egg, honey: 0.05ppb


Cross-reaction rate: AOZ 100%, AMOZ <0.1%, AHD <0.1%, SEM <0.1%


Recovery rate:
Tissue, egg 95±25%
Honey 85±23%

3. Nitrofuran AOZ Diagnostic ELISA Kit Components

1 Micro-well strips

12 strips with 8 removable

wells each

2 6× standard solution (1mL each) 0ppb 0.01ppb
0.03ppb 0.09ppb
0.27ppb 0.81ppb
3 Enzyme conjugate 7ml red cap
4 Antibody working solution 7ml blue cap
5 Substrate A 7ml white cap
6 SubstrateB 7ml black cap
7 Stop solution 7ml yellow cap
8 20× concentrated washing buffer 40ml white cap
9 2× concentrated redissolving solution 50ml transparent cap
10 2-Nitrobenzaldehyde(C7H5NO3) 10ml black cap

4. ELISA procedure


4.1 Description
1) Bring all reagents and microwell strips to room temperature (20-25°C) before use;
2) Return all reagents to 2-8°C immediately after use;
3) The reproducibility of ELISA assays largely depends on the consistency of plate washing. Correct plate washing is the key to ELISA procedures;
4) During the constant temperature incubation, all samples and reagents must be protected from light, and each microplate is sealed with a cover film.


4.2 Operating Procedure
1) Put the kit at room temperature (20-25°C) for at least 30 minutes, note that each reagent must be shaken and mixed well before use, and put the required microwell strips into the plate frame. Unused microplates should be resealed and stored at 2-8°C rather than frozen.
2) Solution preparation: 40 mL of 20× concentrated wash buffer diluted 1:19 with deionized water (1 part 20× concentrated wash buffer + 19 parts deionized water). Or prepare as needed. .
3) Numbering: Number the microwells according to the samples and standard solutions; each sample and standard solution should be made in duplicate, and their positions should be recorded.
4) Add 50 µL of sample or standard solution to separate double wells; add 50 µL of enzyme conjugate and 50 µL of antibody working solution to each well, and shake the plate by hand to mix gently. Seal the microplate with a cover film and incubate at 25°C for 30 min.
5) Pour out the liquid in the microwell, pat dry with absorbent paper, add 250 µL/well of washing buffer to wash the microwell plate for 15-30 s, then remove and pat dry with absorbent paper, repeat 4-5 times. (If there are air bubbles after tapping, use a clean tip to cut them off).
6) Color development: Add 50 µL of Substrate A and 50 µL of Substrate B to each well. Shake the plate by hand to mix gently and incubate at 25°C for 15 min in the dark for color development.
7) Detection: Add 50 µL of stop solution to each well. Shake the plate by hand to mix gently. Set the wavelength of the microplate reader to 450 nm to determine the OD value of each well. (It is recommended to read the OD value of dual wavelength 450/630nm within 5 minutes).

Nitrofuran AOZ Elisa Diagnostic Kits Rapid Test Kit For Fish 96 Wells/Kit Sensitivity 0.01

5. Storage and validity period


Storage: 2-8 ℃ storage, do not freeze.
Expiry date: 12 months; production date is on the box.
Note: If the microplate vacuum packaging leaks, it can still be used without affecting the test results, so you can use it with confidence.

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In case of external factors such as the epidemic, the delivery may be delayed)

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces, which is convenient for customized products.

Q3: How is your factory doing in terms of quality control?
A3: We have nationally certified ISO9001 and ISO13485. Our production process conforms to standard procedures to ensure optimum product quality.

Q4: How to provide after-sales service?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance via video, telephone, etc.

Q5: What is the payment method?
A5: We receive payment by T/T.

Q6: How to ship?
A6: Choose the best shipping method for you by getting quotes from our many cooperative carriers, and also ship according to your requirements.

Send your message to this supplier
Send Now

Nitrofuran AOZ Elisa Diagnostic Kits Rapid Test Kit For Fish 96 Wells/Kit Sensitivity 0.01

Ask Latest Price
Brand Name :
Green Spring
Model Number :
LSY-10002
Certification :
ISO13485,ISO9001
Place of Origin :
China
MOQ :
1kit
Price :
Negotiable
Contact Supplier
Nitrofuran AOZ Elisa Diagnostic Kits Rapid Test Kit For Fish 96 Wells/Kit Sensitivity 0.01

Shenzhen Wensidun Technology Co., Ltd.

Active Member
3 Years
shenzhen
Since 2018
Business Type :
Manufacturer, Agent, Exporter, Trading Company, Seller
Total Annual :
30000000-45000000
Employee Number :
500~1000
Certification Level :
Active Member
Contact Supplier
Submit Requirement