Florfenicol Rapid Test Strip 96 Tests/Kit for Milk 0.2 ~ 0.3 ppb
1. Specifications
8 strips/bottle, 12 bottles/kit
2. Brief
The Florfenicol rapid test strip is used for testing Florfenicol residue in milk(including pure milk and fresh milk) and goat milk qualitatively. The whole test only need 8min, east to operate with high sensitivity.
3. Detection limit
0.2~0.3ug/kg (ppb)
4. Florfenicol Rapid Milk Test Kit Contents
1 | Florfenicol test strip | 8strip/bottle |
2 | Red powder micro-well | 8 micro-well/bottle |
3 | Desiccant | 2piece/bottle |
4 | Instruction | 1 piece |
5. Florfenicol Rapid Milk Test Kit Principle
The Florfenicol rapid test strip is based on competitive inhibition immuno-chromatographic principle. In the flow process, Florfenicol in the sample combined with Florfenicol specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Florfenicol-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Florfenicol residue or concentration lower than detection limit, T line is darker then C line; when the concentration is equal to or higher than detection limit, T line is lighter than C line or T line has no color or T line has same color with C line. No matter whether there is Florfenicol residue in sample, C line will appear, it means the test is valid.
6. Operation procedures
6.1 Please read the manual carefully before use. Return the test strips and samples to be used to room temperature.
6.2 Take out the required bottle from the kit, take out the required microwell, mark it accordingly, please use it within 1 hour. Remember to seal the lid to avoid moisture.
6.3 Use a micropipette to take 200ul of the sample into the microwell, pipette 5 times repeatedly, mix the sample with the reagent in the microwell, until there is no solid as judged by the naked eye (this is a very important step).
6.4 Incubate at 40±2°C for 3 minutes. Then insert the test strip into the microwell and place the end with the MAX in the liquid.
6.5 Insert the test strip into the liquid for 5 minutes, then read the result.
7. Test Result Interpretation
Color depth comparison of T line and C line | Result judgment | Result analysis |
T line > C line | Negative | Florfenicolresidue is lower than detection limit in sample |
T line = C line | Weak positive | Florfenicol residue is equal to detection limit in sample |
T line < C line or T line is invisible | Positive | Florfenicol residue is higher than detection limit in sample |
C line is invisible | Invalid | The test strip is invalid, test again |
8. Precautions
1) Please use test strips at room temperature, do not use expired test strips.
2) Cap the bottle immediately after removing the reagent. If the 8 microwells cannot be used up at one time, cover the microwells immediately, put them back in the bottle, and store them in an airtight container.
3) Do not touch the white film surface in the middle of the test strip, avoid direct sunlight and direct blowing of fans.
4) The milk sample should be completely liquid without any lumps, sourness and sedimentation.
5) Use the test strip again for a positive result.
9. Specificity
This product has no cross-reaction with Quinolones, Sulfonamides and Tetracyclines etc.
10. Storage and expiry date
Storage: Store at 2-8 ℃ in dark, sealed, dry place, no frozen.
Expiry date: 12 months; date of production is on box.
Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In the event of the epidemic and other external factors, there may be delays in shipping)
Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.
Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.
Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.
Q5: What is the payment method?
A5: We receive payment by T/T.
Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.