Specifications
Brand Name :
Green Spring
Model Number :
GF102BS1-07
Certification :
CE
Place of Origin :
China
MOQ :
1kit
Price :
Negotiable
Payment Terms :
T/T
Supply Ability :
5000000 tests per day
Delivery Time :
7~14days
Accuracy :
99.68%
Specificity :
100%
Sensitivity :
98.84%
Sample :
Nasal swab sample
Type :
Antigen Self Test Kit
Results time :
15 ~ 20 minute
Specification :
1 tests/Kit
Precautions :
Avoid skin and eye contact with the buffer liquid.
Description

COVID-19 Antigen Self Test Kit 1 Tests/Kit CE for Nasal Swab Sensitivity 98.84%

Typical symptoms of COVID-19

· Eye symptoms

COVID-19 patients can have ocular symptoms, mainly conjunctivitis, with a prevalence of 0.8% to 31.6%. The main ocular symptoms of patients infected with the COVID-19 are eye pain, itching, foreign body sensation, tearing, and excessive eye secretions, mainly manifested as conjunctival congestion and conjunctival edema. Eye symptoms can appear 1 to 7 days before fever or respiratory symptoms, or after symptoms such as fever.

· Nervous system symptoms

Although patients with new coronary pneumonia are mainly manifested by respiratory symptoms, they can be accompanied by a variety of neurological symptoms during the disease process. Some patients even have neurological symptoms as the first symptoms without typical respiratory symptoms.

Patients with severe new coronary pneumonia are more prone to ischemic stroke, and the occurrence of stroke may further lead to poor prognosis for these patients, and some patients may die of stroke. The key to treatment is to prevent mild cases from progressing to severe cases.

· Skin manifestations

The skin manifestations of patients with new coronary pneumonia mainly occur on the trunk and extremities.

Among the early skin manifestations of new coronary pneumonia, erythema and papules are the most common manifestations, followed by papules, vascular lesions, including ecchymosis, petechiae, purpura, frostbite appearance and Raynaud's phenomenon, cherry hemangioma and acral purple papules , Urticaria. In addition, it can also manifest as a varicella-like rash or even a scaly rash.

Materials Provided

Component Description Specification
1 test/kit
Test cassette Foil ouched test device containing one reactive strip. 1
Sterile swab For sample collection and transfer. 1
Inside page Instructions for use. 1
Extraction buffer Dissolve the sample 1
The certificate of conformity 1
Packages with holes Be used as tube stand (optional). 1

Detection Limit


The limit of detection (LOD) for the SARS-CoV-2 Antigen Rapid Test is 4 x 102 TCID50/mL.

Matrix LOD Concentration TCID50/mL Number of Positive/ Total %Detected

A viral sample inactivated by gamma

irradiation

4 x 102TCID50/mL

20/20

100%

Interference


The following interfering substances have no impact on SARS-CoV-2 Antigen Rapid Test (Colloidal Gold).

No. Interfering Substance Final Test Concentration
1 Mucin 0.54%
2 Menthol 1.4 mg/mL
3 Whole Blood 5%
4 Triamcinolone acetonide 1 ng/mL
5 Tobramycin 5 μg/mL
6 Levofloxacin 1.5 μg/mL
7 Mupirocin 12 mg/mL
8 Oxymetazoline 9%v/v
9 Nasal Spary 16%v/v
10 Dexamethasone 0.5 μg/mL

Hook Effect

No high dose hook effect was observed when tested with up to a concentration of 1.3 x 106 TCID50/mL of heat inactivated SARS-CoV-2 virus.

Warnings And Important Information

1. The test is designed for external use outside human body only. Please do not ingest. Avoid skin and eye contact with the buffer liquid.

2. Failure to follow the instructions may affect the test result. The final diagnosis should be confirmed by a physician.

3. Keep it out of reach of children.

4. Persons with reduced vision or mobility should ask for assistance.

5. Do not use the test if test components are damaged.

6. Use only the materials supplied with this test. Do not reuse the test or test components.

7. The test should be performed immediately, latest one hour after opening the foil pouch (at 20-30°C, humidity<60%).

Antigen Self Test Kit Test Procedure


1. Blow your nose. Wash or disinfect your hands. Remove the test cassette by tearing open the foil pouch and place it in front of you.
2. Tear off the seal of extraction buffer tube, Press in the perforated hole on the top of the packaging and use the hole as a tube stand.
3. Remove the swab. Do not touch the sterile tip of the swab. Instead, grasp the swab by the handle. Insert the swab about 2.5 cm deep into your nostril until you feel resistance.

Home Covid 19 Antigen Test Self Test Kit 1 Tests/Kit CE For Nasal Swab Sensitivity 98.84%

4. Collect sample from left and right nostrils with the same swab: Rub the swab against the inner wall of the nose and turn it at least 5 times to ensure sufficient sample is collected. Repeat the process in the other nostril.
Note: Children under 15 years of age (at least 2 years old), and people including the elderly and sick who are unable to perform the test themselves should be tested by another adult. To sample a child, insert a cotton swab into one of their nostrils until you feel some resistance (about 2 cm). Rotate the swab against the nasal wall 5 times. Repeat the sampling process by removing the swab and inserting the same swab into the other nostril. If the child feels any pain, do not continue the test.
5. Dip a cotton swab into the tube and make sure it is well mixed with the extract by stirring and dipping up and down at least 5 times. Let the cotton swab soak for a minute.
6. Slowly pull the swab out of the tube while gently squeezing the sides of the tube to retain as much liquid in the tube as possible.

Home Covid 19 Antigen Test Self Test Kit 1 Tests/Kit CE For Nasal Swab Sensitivity 98.84%

7. Place the dropper tip firmly on the extraction buffer tube and mix the liquid thoroughly.
8. Drop 3 drops into the sample well (S) on the test card.
9. Interpret the test result between 15-20 minutes. The result after 20 minutes is invalid.

Home Covid 19 Antigen Test Self Test Kit 1 Tests/Kit CE For Nasal Swab Sensitivity 98.84%

Interpretation Of The Test Result


Check whether a line is visible at the control line (C). The color thickness of the control line (C) is irrelevant. If it is not visible, the test was not performed correctly and a new test with a new test set must be performed.

Storage and disposal


Store at room temperature (2-30°C or 35.6-86 T).
Shelf life 12 months (from production date to expiration date).
Test cassettes must be stored in airtight foil pouches until use. Do not use after expiration date.
Waste from used tests should be disposed of according to local regulations.

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In the event of the epidemic and other external factors, there may be delays in shipping)

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.

Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.

Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.

Q5: What is the payment method?
A5: We receive payment by T/T.

Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.

Send your message to this supplier
Send Now

Home Covid 19 Antigen Test Self Test Kit 1 Tests/Kit CE For Nasal Swab Sensitivity 98.84%

Ask Latest Price
Brand Name :
Green Spring
Model Number :
GF102BS1-07
Certification :
CE
Place of Origin :
China
MOQ :
1kit
Price :
Negotiable
Contact Supplier
Home Covid 19 Antigen Test Self Test Kit 1 Tests/Kit CE For Nasal Swab Sensitivity 98.84%

Shenzhen Wensidun Technology Co., Ltd.

Active Member
3 Years
shenzhen
Since 2018
Business Type :
Manufacturer, Agent, Exporter, Trading Company, Seller
Total Annual :
30000000-45000000
Employee Number :
500~1000
Certification Level :
Active Member
Contact Supplier
Submit Requirement