Specifications
Brand Name :
AUPO
Model Number :
BF142X
Certification :
CCC,VDE,ROHS
Place of Origin :
CHINA
MOQ :
1000Pieces
Price :
Negotiable
Payment Terms :
T/T, Western Union
Supply Ability :
1000KKPCS
Delivery Time :
1-2 Weeks
Packaging Details :
Bulk,100pcs/Bag
Fuse Type :
Thermal Cutoff Fuse
Rated voltage :
250V
Rated current :
16A
Tf :
142C
Size :
4X11MM
Terminal :
Axial
Lead diameter :
1.0mm
Max temp .limit :
160C
Description

Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC

Application

Communications:mobile terminal

Auto:Air condition heated seats ABS

Household electrical appliances:Soybean milk machine/hair dryer/electric iron Electric water heater Juice extractor More

Major Appliances

Air-condition Washing machine

Photoelectricity

Photoelectricity halogen lamp/LED/Star capacitor

Electric motorcar

Battery charging

Industrial control and automation:robot

Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC

Size (mm)

Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC

Specification

Part

Number

Rated

functioning

temp.

Fusing-off temp. Holding temp.

Maximum

temp .limit

Rated

current

Rated

voltage

P/N (Tf) (Th) (Tm) (Ir) (Ur)
BF73X 73℃ 70±2℃ 58℃ 150℃ 16A 250V
BF77X 77℃ 74±2℃ 62℃ 150℃ 16A 250V
BF84 84℃ 82±2℃ 69℃ 150℃ 16A 250V
BF94X 94℃ 90±2℃ 79℃ 150℃ 16A 250V
BF99X 99℃ 95±2℃ 84℃ 150℃ 16A 250V
BF104X 104℃ 101±2℃ 90℃ 150℃ 16A 250V
BF113X 113℃ 110±2℃ 98℃ 150℃ 16A 250V
BF117X 117℃ 114±2℃ 102℃ 160℃ 16A 250V
BF121X 121℃ 118±2℃ 106℃ 160℃ 16A 250V
BF133X 133℃ 131+2/-3℃ 119℃ 160℃ 16A 250V
BF142X 142℃ 138+2/-3℃ 127℃ 160℃ 16A 250V
BF157X 157℃ 154+2/-3℃ 142℃ 172℃ 16A 250V
BF172X 172℃ 169+2/-3℃ 157℃ 189℃ 16A 250V
BF184X 184℃ 181±2℃ 169℃ 210℃ 16A 250V
BF192X 192℃ 189±2℃ 177℃ 250℃ 16A 250V
BF229X 229℃ 226±2℃ 201℃ 380℃ 16A 250V
BF240X 240℃ 236±2℃ 201℃ 300℃ 16A 250V
BF257X 257℃ 254±2℃ 200℃ 450℃ 16A 250V

Environmental

1) Comply with the RoHS environmental directives.

2) Comply with SONY SS - 00259.

3) Comply with the REACH regulation SVHC (high attention substance) material content
requirements.

Packaging

A small package includes 100Pcs. A big package includes 10 small packages.One big package
contains 1000pcs of thermal cutoffs (10×100pcs)

AUPO Thermal Links Catalogue

Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC

Normal questions in design and use

Thermal cutoff is a precise, stable safety component. The TCO would fuse abnormally due to improper design, installment and work environment. In order to use TCO properly, here comes some info for your reference.

Q: Technical Terms— What are the meanings of rated functioning temperature (Tf),Holding temperature(Th),Maximum temperature limit(Tm)?

A: Pls refer to the explanation of technical terms. (Explanation of nouns)

Q: Can thermal cutoff be used as current fuse?

A: The answer is NO. The TCO is only sensitive to temperature, Pls use the CTO strictly under the current and voltage which required.

Q: Why there is no conduct for TCO sometime after soldering? Why TCO can be open in test sometime after soldering and fixing? How to avoid these kinds of problems?

A: This is maybe caused by the temperature of welding. During the process of welding, the ambient temperature of TCO has reached the functioning point. As a result, the TCO could fuse or serious be damaged. The welding point is too close to the CTO, the welding time is too long, the temperature of welding is too high are some of the wrong behavior.

Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC

To reduce and avoid the damage made to the CTO, we suggest customers pay attention to the following tips:

1. The distance between the welding point and the body of the CTO should be more than 10mm. ( As showed in Figure4.)

2. The welding time should be less than 3s.

3. Welding fixture should be applied when the welding is manual. Such as cliping an aluminum block (or other metals which are good at dissipating the heat) with the lead wires to help dissipate the heat.

4. Immerse the lead wires into the cooling liquid (like alcohol) after the welding.

Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC

Send your message to this supplier
Send Now

Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC

Ask Latest Price
Brand Name :
AUPO
Model Number :
BF142X
Certification :
CCC,VDE,ROHS
Place of Origin :
CHINA
MOQ :
1000Pieces
Price :
Negotiable
Contact Supplier
Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC
Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC
Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC
Aupo Thermal Cutoff Fuse TF 142℃ 250V 16A BF142X Axial Leaded Metal Case Temperature Thermostat Fuse With VDE ROHS CCC

Aolittel Technology Co.,Ltd

Site Member
7 Years
guangdong, dongguan
Since 2017
Business Type :
Manufacturer, Exporter
Total Annual :
3,750,000-5,000,000
Employee Number :
400~500
Certification Level :
Site Member
Contact Supplier
Submit Requirement