Canaan 50th BTC Asic Miner , Avalon 1066 Pro 55th 3250w 3300w Mining Machine
Model AvalonMiner 1066 from Canaan mining SHA-256 algorithm with a maximum hashrate of 50Th/s for a power consumption of 3250W.
Product Name | Avalon 1066 Avalon A1066 pro | |
Algorithm | SHA256 | |
85Hashrate | 50th 55th | |
Power consumption | 3250w 3300w±10% |
Also known as | A1066 |
---|---|
Release | September 2019 |
Size | 195 x 292 x 331mm |
Weight | 11400g |
Chip name | A3205 |
Chip size | 16nm |
Chip count | 342 |
Noise level | 75db |
Cooling | 12038 Fan |
Fan(s) | 4 |
Power | 3250W |
Interface | Ethernet |
Temperature | -5 - 35 °C |
Humidity | 5 - 90 % |
Safety regulations
Warning: In order to prevent equipment damage, falling, electric shock, fire and other accidents that threaten personal safety, please install and use strictly in accordance with the instructions. Do not modify the equipment and replace parts by yourself.
§ Do not use a power supply that exceeds the rated voltage range
§ Do not place the equipment in unstable places
§ When inspecting and repairing equipment, please entrust professionals to operate
§ When the equipment is abnormal, it is necessary to cut off the power supply quickly and contact the after-sales service
Indicator light
Ø The indicator flashes red several times after power-on
Ø After the device is started, the indicator light will be white for about three seconds. During this time, press the FUNC key to enter the configuration mode
Ø Under normal mining status, the indicator light is green
Ø During system preparation, the indicator light is yellow
Ø When the system is overheated, the indicator light is red
Ø When the system is running, use the FMS software or manually press the FUNC key, the indicator light is always white, press it again to restore the original color
Ø Restore factory settings: When power on (before the indicator flashes red), press the FUNC function key for five seconds, until the white light flashes to indicate success, then press RESET or disconnect the power to restart.
Operating mode
This device has two working modes: "normal mode" and "configuration mode".
Normal mode
Normal working mode. The device runs in this mode for most of its life cycle. In this mode, the network can use DHCP (dynamically obtained) or static IP, and the factory setting is DHCP.
Configuration mode
Press the FUNC key during the white light period (about three seconds) after starting, the device will enter this mode.
In this mode, the IP address is static (address: 192.168.168.168, subnet mask: 255.255.255.0). You can access the built-in web service of the device through a PC browser, and then configure the network, mining pool, password and other information.
Set the PC to a static IP address: 192.168.168.100 (or any other non-conflicting address in the same network segment), subnet mask: 255.255.255.0, and connect the device to the same network (under the same switch or router, or PC and Equipment network cable is directly connected).
1. Right click and open "Network and Internet" settings.
2. Change the adapter options, disable WLAN, and enable Ethernet.
You can use the browser to visit http://192.168.168.168/ to configure the device (modify the static IP, etc.). After the device configuration is completed, it needs to be restarted to take effect. You can click Reboot on the left side of the console, or manually power off and restart. Don’t forget to switch the network connection so that the device cannot access the Internet.
Use the browser to revisit the modified IP address. If the indicator light is green, the operation is correct.
System settings
Access the built-in web service of the device through a browser, and you can access the device console after logging in.
User login
The default user name: root, the default password: root, you can see the Overview page after logging in.