Allen Bradley Modules 1747-AIC 1747AIC AB 1747 AIC Link Coupler New Sealed
Product Description:
The ground conductor of the motor cable should be connected to the drive ground (GRD) terminal directly. Connecting this ground conductor to a cabinet ground point or ground bus bar may cause high frequency current to circulate in the ground system of the enclosure. The motor end of this ground
conductor must be solidly connected to the motor case ground. Shielded or armored cable may be used to guard against radiated emissions from the motor cable. The shield or armor should be connected to the drive ground terminal and the motor ground as outlined in the Grounding section of this Installation
chapter. Common mode chokes are recommended at the drive output to reduce the common mode noise. An RFI filter can be used and in most situations provides an effective reduction of RFI emissions that may be conducted into the main supplylines. If the installation combines a drive with sensitive devices or circuits,it is recommended that the lowest possible drive PWM frequency be programmed.
Related Product Recommendation:
1485C-P1A50 | 1794-IB16D | 1747-L542 |
1485C-P1A500 | 1794-IB8 | 1747-L543P |
1485C-P1BS200 | 1794-IE4X0E2 | 1747-L551 |
1485C-P1BS420 | 1794-IE4XOE2 | 1747-L553 |
1485C-P1BS75 | 1794-IF2XOF2I | 1747-M11 |
1485C-P1CG150 | 1794-IF4I | 1747-MNET |
1485C-P1CG300 | 1794-IJ2 | 1747-OCPCM2 |
1485C-P1CG50 | 1794-L34 | 1747-OCVGA1 |
1485C-P1CG600 | 1794-OA8 | 1747-SCNR |
1485C-P1E200 | 1794-OA8I | 1747-SDN |
1485C-P1E420 | 1794-OB16 | 1747OC-EBCBA |
1485C-P1E75 | 1794-OB16P | 1756-A17 |
1485C-P1G200 | 1794-OB32P | 1756-BA1 |
1485C-P1G420 | 1794-OB8 | 1756-BA2 |
1485C-P1G75 | 1794-OB8EP | 1756-CFM |
1485C-P1L200 | 1794-OE4 | 1756-CN2 |
1485C-P1L420 | 1794-OE8H | 1756-CN2R |
1485C-P1L75 | 1794-OF4I | 1756-CNB |
1485C-P1M5-C | 1794-PS1 | 1756-CNB |
1485C-P1M5-Z5 | 1794-TB2 | 1756-CNBR |
1485C-P1N5-C | 1794-TB3 | 1756-DHRIO |
1485C-P1N5-M5 | 1794-TB32 | 1756-DHRIO |
1485C-P1W100 | 1794-TB3G | 1756-DMA31 |
1485C-P1W300 | 1794-TB3S | 1756-DMD30 |
1485C-P1W5-C | 1794-TBN | 1756-DMF30 |
1485C-P1W5-N5 | 1794-TBNF | 1756-DNB |
1485C-P1W5-Z5 | 1756-L1M2 | 1756-DNB/D |
1485C-P1W600 | 1747-KE | 1756-EN2F |
1485C-P1X2N5-M5 | 1747-L20C | 1756-EN2T |
1442-EC-1140A | 1747-L30C | 1756-EN2TXT |
1756-M02AE | 1747-L514 | 1756-EN3TR |
Product's Character:
After starting RSLogix 5000 and either starting a new project or opening an existing project, make sure
that you are OFFLINE with the ControlLogix processor. I/O configuration is only available when offline.
If you have not already defined the contents of your ControlLogix chassis under your project's "I/O
Configuration" folder, you will need to define the ControlNet bridge module at a minimum. Use the right
mouse button to click on the "I/O Configuration" folder, then choose "New Module" from the pop-up menu.From the dialog box that appears, choose the ControlNet bridge of the type (1756-CNB or 1756-CNBR)and series that you are using. In the next screen, you will need to name the ControlNet bridge and
indicate its position in the ControlLogix chassis (slot 0 is the leftmost).After defining the ControlNet bridge, use the right mouse button to click on the ControlNet bridge under"I/O configuration", then choose "New Module" from the pop-up menu
1746-NO8V Analog Voltage Output Module AB
1746-NR4 RTD Input Module AB
1746-NR8 RTD Input Module AB
1746-NT4 Thermocouple Input Module AB
1746-NT8 Thermocouple Input Module AB
1746-OA16 120/240V AC Output Module AB
1746-OA8 120/240V AC Output Module AB
1746-OAP12 High Current 120/240V AC Output Module AB
1746-OB16 Current Sourcing DC Output Module AB
1746-OB16E Isolated Sourcing DC Output Module AB
1746-OB32 Current Sourcing DC Output Module AB
1746-OB32E Isolated Sourcing DC Output Module AB
1746-OB6EI Isolated Sourcing DC Output Module AB
1746-OB8 Current Sourcing DC Output Module AB
1746-OBP16 High Current Sourcing DC Output Module AB
1746-OBP8 High Current Sourcing DC Output Module AB
1746-OG16 Current Sinking TTL Output Module AB
1746-OV16 Current Sinking DC Output Module AB
1746-OV32 Current Sinking DC Output Module AB
1746-OV8 Current Sinking DC Output Module AB
1746-OVP16 High Current Sinking DC Output Module AB
1746-OW16 Relay Output Modle AB
1746-OW4 Relay Output Modle AB
1746-OW8 Relay Output Modle AB
1746-OX8 Relay Output Modle AB
1746-P1 Power Supply Module AB
1746-P2 Power Supply Module AB
1746-P3 Power Supply Module -DC AB
1746-P4 Power Supply Module AB
1746-P5 Power Supply Module -DC AB
1746-P6 Power Supply Module -DC AB
1746-P7 Power Supply Module -DC AB
1746-QS Synchronized Axes Module AB
1746-QV Open-Loop Velocity Module AB
1746-SIM Input Simulator AB
1746SC-INI4I Analog Current Input Module Spectrum Controls
1746SC-INO4I Analog Current Output Module Spectrum Controls
The use of the product:
1.aluminum smelting machines
2.transmission and distribution.
3.combustion control systems,
1.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.
2. new and original
3.1 year warranty
Our advantages:
1. Improve efficiency
2.2000+ suppliers with us, we could help you to get any components which is difficult to get.
3.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.
1.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
2.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .
3.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )