ABB Module DAI05 3ASC25H203 ABB DAI05 3ASC25H 203 MANN FILTER reputation based
Product Description:
If all of the 8 channels of the group are used as inputs, and if in addition the UP5 terminal is left unconnected, no restrictions exist for the inputs. The input signal voltages then may be within -30 V and +30 V. There is no restriction for the input/output group concerning its safety against reversed polarity.
of the varistor.If the counter is used in the operating modes 1 or 2 (up-counter), the output A 62,00 is only available for the counter. If the output is to use as a normal digital output, it has to
be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows
Related Product Recommendation:
CI531 3BSE003825R1 | PDK02 | 07KT97B |
CI532V01 3BSE003826R1 | PDS01 | 07KT97C |
CI532V02 3BSE003827R1 | PDV01 | 07KT97 |
CI532V02 3BSE003827R1 | PE01 | 07KT97B |
CI532V04 3BSE003829R1 | PEA01 | 07KT97B |
CI540 3BSE001077R1 | PEA02 | 07KT97B |
CI570 3BSE001440R1 | PEA03 | 07KT97B |
CI590 3BHT340092R1 | PEB02 | 07KT98E2 |
CI615 3BHT300024R1 | PEB03 | 07MK92 |
CI626A 3BSE005023R1 | PGM01 | TC50 |
CI630 3BSE011000R1 | LL02 | ICFC16l1 |
CI830 | LL03 | ICSF08D1 |
CI854AK01 3BSE030220R1 | LM01 | ICSK20F1-120 |
CI857K01 3BSE018144R1 | LM21 | ICSK20F1-230 |
CI860 CI860K01 3BSE032444R1 | LT02 | ICSK20F1-24 |
CM30/000S0E0/STD | LZ01 | ICSK20N1 |
CMA112 3DDE300013 | LZ02 | ICSA04B5 |
CMA114 3DDE300013 | MA01 | ICSE08B5 |
CMA121 3DDE300401 | MA02 | 07KR31 |
CMA132 3DDE300412 | MA03 | 07KR31 |
CS300E PAC 031-1053-00 | MA12 | 07KT31 |
CS513 3BSE000435R1 | MB01 | 07MK62 |
D0910S | MB02 | 35NE90 |
DAI01 | MB11 | 35GS91 |
C100/0100/STD | MB12 | 35GS91 |
C1900/0263/0260A C1900/0263 | MB21 | 35DS91 |
SS25 | MR01 | 35AB94B |
SS41 | MS01 | 35AA92C-E |
SV01 | MT01 | 35EK90 |
TET106 | MV01 | 35EK91 |
07SK90R1 GJR5250200R0001 | MV03 | 35TP90 |
Product's Character:
If the open-circuit or short-circuit monitoring is configured, the detected error is displayed by the red LED Ovl as long as it is present. In the PLC system an error message is stored (FK4, error number 9).
In order to avoid error messages with unused analog inputs, it is useful, not to configure this channels for Pt100. Connection of Pt100 temperature sensors in 3-wire configuration If the sensors are located close together, only one core is needed as
the return wire AGND1. In the operating mode "Pt100 in 3-wire configuration" two adjacent analog inputs belong together (e.g. EW 6,00 and EW 6,01). For configuration, both inputs must be configured to the
desired operating mode, see configuration table Fig. The constant current of the one channel flows through the Pt100 resistance sensor, the constant current of the other channel through one of the wires.
The basic unit 07 KT 94 calculates the measuring value from the two voltage drops and stores it under the odd address
CI522AK06 3BSE018453R1 ABB Cable Kit ABB
CI526 3BSE006085R1 CI526 Interface Module ABB
CI526V1 3BSE012870R1 CI526 Interface Module ABB
CI531 3BSE003825R1 RS-232 Interface Submodule ABB
CI532V01 3BSE003826R1 RCOM Interface Submodule ABB
CI532V02 3BSE003827R1 MODBUS Interface ABB
CI532V03 3BSE003828R1 Communication Interface Module - Siemens 3964(R) ABB
CI532V04 3BSE003829R1 AB Interface ABB
CI532V05 3BSE007297R1 Generic MVI Module ABB
CI532V09 3BUP001190R1 Accuray Interface Module ABB
CI534V02 3BSE010700R1 MODBUS Interface Submodule ABB
CI534V04 3BSE010702R1 Allen- Bradley Interface Sub Module ABB
CI535 3BSE003830R1 Free- Programmable MVI Sub Module ABB
CI540 3BSE001077R1 CI540 S100 I/O Bus Extension ABB
CI541 3BSE014665R1 Profibus Interface Sub Module ABB
CI541V1 3BSE014666R1 Profibus Interface Sub Module ABB
CI545 3BSE011063R1 Ethernet MVI Module ABB
CI545V01 3BSE011063R1 Ethernet MVI Module ABB
CI547 3BNP004429R1 MB300 Communication Board with Slave Processor ABB
CI560 3BUC98002R0001, 3BUC980002R1 TRIO Field Bus Interface Module ABB
CI570 3BSE001440R1 CI570 MasterFieldbus Controller ABB
CI572 3BSE017712R1 LonWorks Communications Module ABB
CI610 3BHT300003R1 I/O Bus Extender ABB
CI615 3BHT300024R1 ABB I/O Bus Coupler ABB
CI615K01 3BSE000756R1 Bus Extension Kit ABB
CI626V1 3BSE012868R1 Communication Interface Module ABB
CI627 CI627 Communication Interface Module ABB
CI627A Bus Administrator Module ABB
CI630 3BSE011000R1 CI630 AF100 Communication Interface Module ABB
CI630K02 3BSE011002R1 CI630 AF100 Interface Kit ABB
CI670 3BHT300017R1 Master Fieldbus Module ABB
CI801 3BSE022366R1 Profibus DP-VI Communication Interface Module ABB
CI810A 3BSE013262R1 CI810A AF100 Field Communcation Interface ABB
The use of the product:
1. Customer service in 1-4 hours. If there's any question, please contact with our sales.
2. new and original
3.1 year warranty
Our advantages:
1.Optimize plant operations
2.emission reduction
3.Avoid unplanned downtime
1.Q:Does your goods are new and original ?
A: yes ,they are new and original
2.Q:How about the payment terms ?
A:We frequently use T/T
3.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )