ABB Module DSQC679 3HAC02835 001 ABB DSQC679 3HAC028357 001 DSQC 679 Pendant Cable New New spot folding
Product Description:
The measuring ranges of the analog input channels Resolution in the PLC system:The measured values are converted with a resolution of 12 bits, i.e. 11 bits plus sign for voltage and 12 bits without sign for current. The ranges 0...5 V und ±5 V are converted with 10 bits plus sign.Examples:
Measuring range Range of numbers Further details can be found in volume 2, chapter 5.1 "General
information for the use of analog inputs and outputs".In order to make sure, that unused input channels have a defined 0V level, they may be shorted to AGND. Unused inputs must be configured with "unused".
The relationship between the analog input signals and the converted numbers is illustrated in the following figures.
Related Product Recommendation:
DCP10 | 3ASC25H705/7 | C1900/0263/0260A C1900/0263 |
DDI01 | 3ASU21C110 LU6278 DCU30/7 | C1900/0363 C1900/0363/0360A |
DDO01 | 3AUA489002B4562 | C300/0010/STD |
DI685 3BDS005833R1 | 3BHE022291R0101 PCD230A | CI520V1 3BSE012869R1 |
DI811 3BSE008552R1 | 3BHE023784R2530 PP D113 | CI522 3BSE012790R1 |
DIGITRIC 500 61615-0-1200000 | 3BHE024577R0101 PP C907 BE | CI522A 3BSE018283R1 |
DLM01 | 3BSE001245R1 3BSC640008R1 | CI526 3BSE006085R1 |
DLM02 | 3BSE003879R1 | CI531 3BSE003825R1 |
DO620 3BHT300009R1 | 3BSE011316R1 SDCS-PIN-52 | CI532V01 3BSE003826R1 |
DO630 3BHT300007R1 | 3HAC14550-4 | CI532V02 3BSE003827R1 |
DO810 3BSE008510R1 | 3HAC14551-2 | CI532V02 3BSE003827R1 |
DPW02 | 3HAC17484-8 | CI532V04 3BSE003829R1 |
DRA02 37411-4-0369673 | 3HAC17484-9 | CI540 3BSE001077R1 |
DSAB-02C | 3HNE00313-1 | CI570 3BSE001440R1 |
DSAI110 57120001-DP | 3HNM09846-1 | CI590 3BHT340092R1 |
DCP02 P-37211-4-0369654 | 3HNP04014-1 | CI615 3BHT300024R1 |
CMA112 3DDE300013 | 424K1105 | CI626A 3BSE005023R1 |
CMA114 3DDE300013 | 6638910B1 638910B1PS0084 | CI630 3BSE011000R1 |
AI830A 3BSE040662R1 | 7944831D | CI830 |
07MK92 GJR5253300R1161 | 89AR30 | CI854AK01 3BSE030220R1 |
07NG61R1 GJV3074311R1 | A8PU05ABFW02 | CI857K01 3BSE018144R1 |
07NG63R1 GJV3074313R1 | AI610 3BHT300000R1 | CI860 CI860K01 3BSE032444R1 |
07PS62R2 GJV3074332R2 | AI625 3BHT300036R1 | CM30/000S0E0/STD |
07SK90R1 GJR5250200R0001 | AI630 3BHT300011R1 | CMA112 3DDE300013 |
07ZE61R302 GJV3074321R302 | AI810 3BSE008516R1 | CMA114 3DDE300013 |
07ZE63R302 GJV3074323R302 | AI830A 3BSE040662R1 | CMA121 3DDE300401 |
086363-002 OSPS2 | AV31 AV 31 | CMA132 3DDE300412 |
Product's Character:
Input currents that exceed the measuring range cause the overflow numerical value of +32767. If the measured value is below the range, the underflow numerical value of -32767 is set.The input impedance is ca. 330 Ω. The current input has a self-protecting mechanism. If the input current gets too
high, the shunt is switched off and the value for range overflow is generated. About every second, the unit tries to switch on the shunt again. In this way the correct measurement will succeed after the current has reached a normal value again.The trigger of the self-protecting mechanism is displayed
by the red LED Ovl as long as the overload is present. In the PLC system an error message is then stored (FK4,error number 4).The open-circuit monitoring begins below ca. 3 mA.
The use of the product:
1.provides integrated control, power, safety,
and information solutions for complete plant-wide control in a scalable,
2.emission reduction
3.Avoid unplanned downtime
1. Q:Does your goods are new and original ?
A: yes ,they are new and original
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520