ABB Module SAMC 11 SAMC11 ABB SAMC 11 SAMC 11 STROMBERG SAMC New foreign imports
Product Description:
The input impedance is ca. 330 Ω. The current input has a self-protecting mechanism. If the input current gets too high, the shunt is switched off and the value for range overflow is generated. About every second, the unit tries to switch on the shunt again. In this way the correct measurement
will succeed after the current has reached a normal value again. The trigger of the self-protecting mechanism is displayed by the red LED Ovl as long as the overload is present. Inthe PLC system an error message is then stored (FK4, error number 4). The following figure shows the connection of a 3-wire sensor powered by 24 V DC and of a 2-pole sensor powered electrically isolated. Both sensors work as active current sources 0...20 mA.
Related Product Recommendation:
TET106 | AV41 | DSQC227 YB560103-CE |
TET106-EX.D | AV42 | DSQC223 YB560103-CD |
TEU315-EX.B | AV43 | DSQC205 YB560103-BK |
TEU320 | AV97 | DSQC201 YB560103-BD |
TEU325-EX.B | AV98 | DSQC104 YB560103-AD/1 |
TEU411 | AW01 | DSQC 633A YB560103-AB |
TEU421 | AW02 | DSQC 539 6369901-104 |
TEU310 | AW03 | DSQC 352A 3HAC 031851-001 |
TZF12 | AW05 | DSSR170 48990001-PC 3HAC14265-1 |
TZIF3 | DAI01 | DSSB146 |
TZN124-EX | DAI04 | DSTD150A 48980001-AP/1 DSSB146*BAT2C |
VE93 | DAI05 | DSTD132 |
VV01 | DAO01 | DSTD108P 57160001-UH |
VV03 | DCO01 | DSTD108 5716001-FX |
VV11 | DCP02 | DSTD 110A 3BSE018333R1 |
XB01 | PAA02 | DSTC454 5751017-F 57160001-ABD/ABW |
XI01 | PAB02 | DSTC190 57520001-ER 57160001-TZ |
XI91 | PAR01 | DSTA180 |
XK11 | DDO02 | DSTA160 |
XK12 | XN05 | DSTA131 57120001-CV 57120001-ET |
XK15 | XN06 | DSTA131 57120001-AH |
XK16 | XP01 | DATX130 3ASC25H214 57120001-CV |
XM01 | XU01 | DAPC100 |
XM02 | XU02 | DAI05 3ASC25H203 |
XM03 | XU03 | DAI03 P37131-4-0336025 |
XN01 | XU04 | DCP02 |
XN03 | XU12 | 3ASU21C110 LU6278 DCU30/7 P-37211-4-0369654 |
Product's Character:
It has to be taken into consideration, that in this application the M terminal of the basic unit 07 KT 94 is
the reference potential. AGND1 is not dimensioned for carrying the sum of the sensor currents. The value of the range underflow is stored. If the ope circuit monitoring is configured, the open-circuit event is displayed by the red LED Ovl as long as it is present. In the PLC system an error message is stored (FK4, error number 9). The following figure shows the connection of 2-pole passive- type analog sensors 4...20 mA. If the analog current sensors 4...20 mA are powered from a separate power supply unit, the reference potentials 0V (of the separate power supply unit and the power supply unit for the 07 KT 94) must be interconnected to each other.In the above example, the AGND terminal remains
unused.
DC 371a GJR2 237100 R1, GJR2237100R0001 DC 371a Group Control Module ABB
DC 372a GRJ2 238200R1 , GRJ2238200R0001 Step Control Module ABB
DC 375a GJR2 304400 R1, GJR2304400R0001 DC375a Operating Mode Controller Module ABB
DC 722F A0 3BDH000372R0001 Digital Input/Output Module ABB
DCO 01 0369666 DCO01 Serial Interface Module ABB
DCP 02 P 37211-4-0369654 DCP 02 CPU Module ABB
DCP 10 P37211-4-0338701 DCP10 CPU Module ABB
DCS800-DEMOCASE Field Kit ABB
DCS800-EP1-0020-05 Module Drive ABB
DCS800-EP1-0045-05 Module Drive ABB
DCS800-EP1-0065-05 Module Drive ABB
DCS800-EP1-0090-05 Module Drive ABB
DCS800-EP1-0125-05 Module Drive ABB
DCS800-EP1-0180-05 Module Drive ABB
DCS800-EP1-0230-05 Module Drive ABB
DCS800-EP1-0315-05 Module Drive ABB
DCS800-EP1-0405-05 Module Drive ABB
DCS800-EP1-0470-05 Module Drive ABB
DCS800-EP1-0610-05 Module Drive ABB
DCS800-EP2-0020-05 Module Drive ABB
DCS800-EP2-0045-05 Module Drive ABB
DCS800-EP2-0065-05 DCS800-EP2-0065-05 ABB
DCS800-EP2-0090-05 Module Drive ABB
DCS800-EP2-0125-05 Module Drive ABB
DCS800-EP2-0180-05 Module Drive ABB
DCS800-EP2-0230-05 Module Drive ABB
DCS800-EP2-0315-05 Module Drive ABB
DCS800-EP2-0405-05 Module Drive ABB
DCS800-EP2-0470-05 Module Drive ABB
DCS800-EP2-0610-05 Module Drive ABB
DCS800-PAN Field Kit ABB
DCS800-S01-0020-05 Module Drive ABB
DCS800-S01-0045-05 Module Drive ABB
DCS800-S01-0065-05 Module Drive ABB
DCS800-S01-0090-05 Module Drive ABB
DCS800-S01-0125-05 Module Drive ABB
The use of the product:
1.open architecture to take advantage of traditional or renewable sources of energy!
2.emission reduction
3.Avoid unplanned downtime
1.Provides the lowest Total Cost of Ownership (TCO)
2.emission reduction
3.Avoid unplanned downtime
1. Q:Does your goods are new and original ?
A: yes ,they are new and original
2.Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located Xiamen,
Shenzhen & Hongkong.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could
promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )