General information
SCHNEIDER TSXPSY3610M
Technical ParametersTechnical parameters of Schneider molded case circuit breakerCode
labeling methodSchneider miniature circuit breaker code numbering method:Example:
1-C65N-C20A/2P+VE+30mA+SD, each meaning is1--------- identification numberC65------
Sequence codeN-------- breaking capacity, N is 6000A, H is 10000A, L is 15kAC--------
tripping curve, B is electronic protection, C is power distribution protection, D is power protection20A
------ rated current, there are 1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A2P------- pole number, there are
1, 2, 3, 4 poleVE-------Residual current accessories, VE, VEG, VM, VEA, VM is electromagnetic30mA
-----Remaining operating current, 30, 100, 300mASD------- Optional accessories, there are MX, OF, MN, MV,
SD, Tm, ATM, where SD is the auxiliary contact.
(Email:miya@mvme.cn new & original)
For your reference
Minimum order quantity: 1 piece
Type of payment: 100% Payment in Advance
Warranty: one year
Courier partners: DHL, UPS, TNT, FedEx and EMS
Lead time: 2-3 working days
Technical specification, manuals and data sheets: Available on request
To get our best price & fast quotation, pls send us e-mail now.
Related products
ABB | YXI115B YT204001-AL | HONEYWELL | TC-PRR021 51309288-375 |
ABB | YXU173E YT204001-JK | HONEYWELL | 51198947-100 |
ABB | PFSK163 3BSE016323R3 | HONEYWELL | FC-SDI-1624 |
ABB | PFBK165 3BSE000470R1 | HONEYWELL | CC-TAIM01 51305959-175 |
ABB | DSPC173 57310001-MT | HONEYWELL | SB3610-B |
ABB | DSBC173 57310001-KH | HONEYWELL | TK-IOLI01 51403427-275 |
ABB | PFSK111 5735175-C | HONEYWELL | CC-PCNT01 51405046-175 |
ABB | DSMC112 57360001-HC | HONEYWELL | MC-TAMT04 51305890-175 |
ABB | DSTC120 57520001-A | HONEYWELL | 51403519-160 K4LCN-16 |
ABB | PFSK101 YM322001-ED | HONEYWELL | FC-SDO-0824 SDO-0824 V1.3 |
ABB | DSDO115 57160001-NF | HONEYWELL | TK-PPD011 51309241-175 |
ABB | DATX100 3ASC25H208 | HONEYWELL | TC-PRS021 |
ABB | YXE152A YT204001-AF | HONEYWELL | STG740 STG740-E1GC4A-1-C-AHB-11S-A-50A0-0000 |
About us
MOORE AUTOMATION LIMITED focuse on control systems, from legacy to leading edge.
We have a large inventory of high quality, surplus control system parts. We also distribute many new hardware
and software products to help supporting your existing control systems or utilize the latest control technology.
We have experienced staff, extensive test facilities and we can provide 1-year warranty for all of our surplus parts.
Adequate stock, fast delivery time!!
Email:miya@mvme.cn
TSXP572634M The installation of the low-voltage circuit breaker is correct, which directly affects its
performance and performance. Generally pay attention to the following issues:(1) Before installation,
check whether the technical parameters listed on the nameplate of the low-voltage circuit breaker
meet the requirements for use.(2) The low-voltage circuit breaker should be installed vertically.
The low-voltage circuit breaker wired in front of the board can be installed on the metal bracket or
the metal base plate, but the low-voltage circuit breaker connected behind the board must be installed
on the insulating base plate. The bracket or bottom plate of the fixed low-voltage circuit breaker must be
flat to prevent damage to the insulating base when the screws are tightened. In order to prevent accidents
caused by arcing, the copper busbar of the low-voltage circuit breaker should be packed with 200mm insulation
or phase-interval arc plate from the insulation base.(3) The power supply should be connected to the incoming
terminal of the static contact of the low voltage circuit breaker, and the trip end should be connected to the load.
In order to ensure the protection characteristics of the overcurrent release, the cross section of the connecting
wire should be selected according to the rated current of the trip unit.