Specifications
MOQ :
100
Payment Terms :
T/T
Delivery Time :
1-12 weeks
Packaging Details :
Original packing
Maximum range :
800A~1200A
Sensitivity :
G=2000/IP
Phase difference :
-4
Magnetic zero offset :
±3
Electrical zero offset :
±4
Zero output error :
-1 1
Description

NACA.XXXQ3-S6 / VA Current Transducers

Product Details

product manual

NACA XXXQ3-S6/VA series triple current sensor is suitable for accurate measurement of AC, DC and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.

Performance requirements
parameter name symbol unit parameter condition
Minimum Typical value Max
Electrical parameters
Maximum range IP A 800A~1200A For more details, please contact CRRC
Storage temperature TS °C -40 125
voltage UC V 4.75 5 5.25
Output voltage (linear) Vout V Vout=(Uc/5)·(V0+G·Ip) @UC
Sensitivity G mV/A 2000/Ip @UC=5V
Zero output VO V 2.5 @UC=5V
Current consumption IC mA 39 45 @ UC=5V,No load on Vout
Load Resistance RL 4.7 10
Load capacitance CL nF 5
Output internal resistance ROUT Ω 2 4 8 DC
Performance parameter
Zero output error X0 % -1 1 @TA=25℃,@UC=5V
-1.5 1.5 @-40℃<TA<125℃,@UC=5V
Sensitivity error εG % ±1 @TA=25℃,@UC=5V
±2 @-40℃<TA<125℃,@UC=5V
Electrical zero offset FLY mV ±4
Magnetic zero offset FROM mV ±3
Proportional error .R % 0.5
Linearity error εL % -1 1 of full range
Response time tr μs 2
bandwidth BW kHz 40 @ -3dB
Phase difference ∆φ ° -4 @DC to 1kHz

Dimensions
Series size
1200A Pulse Current Transducer Response Time 2us1200A Pulse Current Transducer Response Time 2us

Procurement information

1. Products can be customized according to your needs. You are welcome to provide physical samples or detailed process drawings to design, produce and process. 2. If there is no special requirement, our company will assign logistics distribution and deliver the goods to customer factory

3. Payment method: delivery after payment, which can be negotiated according to the specific order quantity.

4. The response time of the number of customers should not exceed 8 working hours.

5. Emergency on-site service time shall not exceed 24 hours.

6. Provide emergency support for customer's urgent shortage of spare parts.

Send your message to this supplier
Send Now

1200A Pulse Current Transducer Response Time 2us

Ask Latest Price
MOQ :
100
Payment Terms :
T/T
Delivery Time :
1-12 weeks
Packaging Details :
Original packing
Maximum range :
800A~1200A
Sensitivity :
G=2000/IP
Contact Supplier
1200A Pulse Current Transducer Response Time 2us

Xiamen Sincery Im.& Ex. Co., Ltd.

Site Member
7 Years
fujian, xiamen
Since 2018
Business Type :
Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Total Annual :
10,000,000-60,000,000
Employee Number :
100~120
Certification Level :
Site Member
Contact Supplier