Three Stations Load Box HC9915B
Standard for Three Stations Load Box:
IEC 60669-1, IEC 60884-1 2013 clause 20 and 21, IEC 60950-1, IEC 60598-1, IEC61058-1 and so on
Application of Three Stations Load Box:
This device is used for household and similar purpose fixed electrical appliance switch, plug and socket, coupler for on-off ability, breaking capacity and normal operation life test.
Test Sample of Three Stations Load Box:
Household or similar purpose switches, plugs, sockets
Feature of Three Stations Load Box:
This device is with blue framework and gray cover. The top of this apparatus is the operation control panel on which there are switches for controlling power supply, for the electric capacity conversion and for the load type conversion. There are also the displaying meters of connecting current and voltage as well as power, the buttons of start and stop, alarm, the status indicator light and so on. Below are the according knobs for output voltage adjustment, for current adjustment and for inductance adjustment. There are three stations, each station has the function of resistive, inductive and capacitive Load test. The kind of load test can be chosen by the transferring switch. The load box inside is cooled by the strong wind convection. There are terminals below the load box through which the load box can be connected with the switch and plug-socket endurance tester using the wire. During the process of test, the equipment outputs the current and voltage as well as power.
Parameter of Three Stations Load Box:
Power supply | 3phase 4 wires AC 380V 50Hz |
Stations | 3 stations |
Digital voltage meter | 0~300V, accuracy: ±0.5% |
Digital ampere meter | 0~30A, accuracy: ±0.5% |
Digital power meter | 0~10KW, accuracy: ±0.5% |
Digital power factor meter | 0.3~0.98, accuracy: ±0.5% |
Load method | Resistive, inductive and capacitive load. Three in one, Convertible |
Capacity load | 70uf,140uf,7.3uf can be chosen |
Load output | Each power and interval power can be chosen |
Counter | 0~999999, preset |
Load capacity | 3*10KVA |
Max. of the output current | 30A,when it exceeds 32A, it stopped automatically |
Max. of the output voltage | 300V, when it exceeds 305V, it stopped automatically |
Working environment | 80~106kpa, 5~40℃, (20~90)%RH |
Using place | No violent shaking, without electromagnetic interference and dust, no explosive or corrosive gas. |
Dimension | L*W*H=1200*760*1830mm, 600kg |