Specifications
Brand Name :
True Engin
Model Number :
STA-05B
Certification :
ISO9001
Place of Origin :
China,Hubei
MOQ :
1 UNIT
Price :
Negotiate
Payment Terms :
T/T, L/C, Western Union
Supply Ability :
10000 UNITS/MONTH
Delivery Time :
1~3 days
Packaging Details :
Neutral
Brand :
True Engin
Model :
STA-05B
Certificate :
ISO9001
Size :
115*100*23mm
Weight :
0.3 kg
Control Output :
0~10v/0~5v
Description

High Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask Machine

High Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask Machine

Measurement Tension Amplifier Work With Tension LoadCell for Packing Machine

Measuring amplifiers ensure a stable bridge supply voltage, They amplify the output signal of the load sensors to a standard signal .

1. Preface

Tension transducer STA - 05 is the tension of Intelli gent tension transducer instrument . By using of key operation will complete zero alignment,calibration,convert the left or right tension sensor signal into astan dard industrial control signals, 0 ~ 10V / 0 ~ 5V and 0 ~ 20 mA output signal can be provided to PLC for automatic control .

2. Features

1. 32 bit CPU guarantees high speed, precision, ant-ijamming capability and ensures reliability.

2. The outside has no adjustable potentiometer.

3. The tension sensor can select Differential sensor or Strain- gauge sensor.

4. 0~ 10V/ 0~ 5V and 0~ 20mA output signals can be p-rovided to PLC and display instrument.

5. Use dispensing technology, small volume, light wei-ght.

6. Using DIN rail mounting, simple and convenient.

Parameters
Model STA-05C STA-05B
Power Supply DC 24V
Input Analog singal L+~L-;R+~R-;Left,right STS tension loadcell signal (0~200mv,power supply DC5V) L+~L-;R+~R-;Left,right STSA tension loadcell signal (0~15mv;power supply DC5v)
Control output 1. Vout-GND:DC0~10V/0~5V
2. Iout-GND:DC0~20mA
Fixed output 5V+-GND:DC5V tension loadcell power supply
Outline size 115x100x23mm

er supply.
2 24V - : Negative terminal of tension transducer po -
wer supply.
3 Mc1 : Select output voltage range .
MC1 with MCC disconnect : output 0 ~ 10V.
MC1 with MCC connect : output 0 ~ 5V.
4 Mc2 : Select the calibration value .
MC2 with MCC disconnect : Full scale ca -
libration .
MC2 with MCC connect : Half scale calibr -
ation .
5 Vout : Positive terminal of output voltage , 0 ~ 10V or
0 ~ 5V.
6 GND : N egative terminal of output voltage / current .
7 Iout : Positive terminal of output current , 0 ~ 20mA .

8. Operation and using

(1) Panel and indicators introduction

Panel operation as follows, it has two buttons and th-ree LED. One botoon used to zero alignment, another used to calibrate, three LED used to indicate the wor-king state of tension transducer.

LED2 turns red, LED1,LED3 red twinkle, there are several ways as follows:

Tension sensor connection drops or poor contact. LED1 twinkle shows left tension sensor has problem, LED3 twinkle shows right tensioin sensor has problem, ple-ase check sensor connection.

The difference of signal between left sensor and right sensor is too large. When the LED twinkle , it shows the sensorsignal is too small,please ajust the sensoror change it.

LED2 turns green,LED1,LED3 alternately twinkle,it shows zero alignment and calibration has problem,t-his reason refer to part 9.

Zero calibration operation:

Machine power off, there is no film or film is loose.

Press “Zero alignment” button for 3~5 sec,LED1 tu-rns on.

When LED1 starts twinkle,loosen “Zero alignment” button,the twinkle stops,LED1 turns off, so complete zero alignment.

a. Machine power off. Thread a string through the ree-ler center like what the material does during the act-ual operation.

b. Hang weights on the end of the string while the oth-er end is fixed well. The weights should be moreth-an half of the rated measurement range of the dete-ctor.

c .Make sure that weights fall naturally, the bearing h-ouses of detector reel are spherical universal ones and well lubricated.

d. When full- scale calibration,MC2 with MCC disconn-ect,the weights should correspond to full scale.

When half- scale calibration,MC2 with MCC connect, the weights should correspond to half scale.

e.Press “Calibration” button for 3~ 5 sec, LED3 turns on.

f. When LED3 starts twinkle, loosen “Calibration” but-ton, the twinkle stops, LED3 turns off, so complete calibration.

Packing and delivery:

1. Neutral carton packing
2. One piece in one carton box
3. Normally one controller with two loadcells,this is easy for shipping.
4. One unit shipping
5. Lead time:within 3 days

High Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask MachineHigh Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask MachineHigh Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask Machine

STA-05 Tension signal amplifier.pdf

Send your message to this supplier
Send Now

High Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask Machine

Ask Latest Price
Brand Name :
True Engin
Model Number :
STA-05B
Certification :
ISO9001
Place of Origin :
China,Hubei
MOQ :
1 UNIT
Price :
Negotiate
Contact Supplier
High Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask Machine
High Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask Machine
High Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask Machine
High Precision Tension Amplifier Lightweight For Film Machine 115*x100*23mm For Face Mask Machine

Wu Han Micro Control Electric Co., Ltd.

Active Member
8 Years
hubei, wuhan
Since 1994
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Trading Company, Seller
Total Annual :
2,000,000-3,000,000
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement