Analog Signal Tension Amplifier DC24V With Two Load Sensors High Precision Tension Transducer
Measuring Amplifiers Tension Amplifier DC24V Connecting Two Load Sensors In Printing Machine
Measuring amplifiers ensure a stable bridge supply voltage, They amplify the output signal of the load sensors to a standard signal .
STA-05 Intelligent tension transducer
Features:
1. Key intelligent operation,outside without adjust potentiometer.
2. Hardware and software to restrain power frequency interference, output steady and reliable.
3. Adapt DIN-rail mounting,easy and convenient.
4. Adapt SMT,small size,light weight.
5. Tension controller with STS ans STSA for option.
Parameters | ||
Model | STA-05C | STA-05B |
Power Supply | DC 24V | |
Input Analog singal | L+~L-;R+~R-;Left,right STS tension loadcell signal (0~200mv,power supply DC5V) | L+~L-;R+~R-;Left,right STSA tension loadcell signal (0~15mv;power supply DC5v) |
Control output | 1. Vout-GND:DC0~10V/0~5V 2. Iout-GND:DC0~20mA | |
Fixed output | 5V+-GND:DC5V tension loadcell power supply | |
Outline size | 115x100x23 |
Features:
32 bit CPU guarantees high speed, precision, ant-ijamming capability and ensures reliability.
The outside has no adjustable potentiometer.
The tension sensor can select Differential sensor or Strain- gauge sensor.
0~ 10V/ 0~ 5V and 0~ 20mA output signals can be p-rovided to PLC and display instrument.
Use dispensing technology, small volume, light wei-ght.
Using DIN rail mounting, simple and convenient.
Product category:
STA - 05B : Using strain - gauge sensor , input signal r - ange - 5mv ~ + 10mv.
STA - 05C : Using differential sensor , input signal ran - ge - 100mv~ + 200mv
Notes of Using Tension Detector
1. Set screws A and B should not be too long when the bearing houses are installed on the detector. Other-wisethe force could not cause relevant deformations and displacements on the detector. Use spherical u-niversal bearing houses to avoid the detectors on b-oth sides interacting on each other, causing errors on calibration.
2. The wrap angle of film over detector reel shouldn’t be larger than 120, around 60°would be perfect. The s-ignal detected by detector would be too weak to con-trol tension effectively with a large wrap angle.
3. The load force caused by film tension should not poi-nt to the screw ends of tension detector. Otherwise t-here will be very low or even no output.
4. The screw ends of tension detector should point upw-ards when installed on a wall.
5. If the film is pulled cross the reel from below, the fo-rce caused by film tension pulls but not pushes the tension detector. So the negative and positive detec-tor signal wires should exchange when connected to the controller terminals.
veral ways as follows:
[ 1] Tension sensor connection drops or poor contact. LED1 twinkle shows left tension sensor has problem, LED3 twinkle shows right tensioin sensor has problem, ple-ase check sensor connection.
[2] The difference of signal between left sensor and right sensor is too large. When the LED twinkle , it shows the sensorsignal is too small,please ajust the sensor or change it.