High Precision Load Cell Meter 0~200mv Input For Package Machine ST-10PD Tension Load Cell Meter
Intelligent Tension Meter For Tension Load Cell and Auto Tension Controller
Attention:STM-050 tension meter only display tension,no control signal output,other functions same as STM-10PD.
Parameters | |
Model | ST-10PD |
Power Supply | DC 24V |
Input Analog singal | 1. L+~L-;R+~R-;Left,right tension loadcell signal input |
STS tension loadcell signal (0~200mv,power supply DC5V) | |
STSA tension loadcell signal(0~15mv;power supply DC5v) | |
Control output | 1. Vout-GND:DC0~10V/0~5V |
2. Iout-GND:DC0~20mA/4~20mA | |
(STM-050 without Vout,Iout output) | |
Tension Display | L+R Total tension L: left tension R:right tension |
Fixed output | 5V+-GND:DC5V tension loadcell power supply |
Outline size | 96*48*109mm |
Features:
1. 32 Bit CPU guarantees high speed,precision,anti-jamming capability and ensures reliability.
2. The outside has no adjustable potentiometer.
3. 0~10V /0~5V and 0~20ma/4~20ma output signals can be free to choose.
4. Use dispensing technology, small volum,light weight.
5. Mosaic installation,simple and convenient.
Packing and delivery:
1. All pack with standard Carton box,Neutral with any Logo
2. Each piece in one separate box with manual instruction
3. All model with stock and can be sent out at once
4. All products with warranty 2 years
Using steps
1. Enter C11 ,according to the tension sensor type to set C11 parameter value:if it is differential sensor,the value is set to 0,if it is strain gauge sensor,the value is set to 0.
2. When use the tension meter output to participate the control with PLC ,according to the actural need to set C09/C10.
3. Set the alarm value when it is needed,otherwise it has no alarm with 0.0kg.
4. According to the actual need to set C04 full degree of tension,its value should be 20%~80% of tension sensor rated range.
Notes for use
1. Set screw should not be too long when the bearing hourses are installed on the detector.
2. Use spherical universal bearing hourses.
3. The wrap angle of film over detector reel should not be larger than 120 around 60 would be perfect.
4. The load force caused by film tension should not point to he screw ends of tension detector.
5. The screw ends of tension detector should point upwards when installed on a wall.
6. If the force caused by film tension pulls but not pushes the tension detector,so the negative and positive detector signal wires should exchange when connected to the tension meter.