Specifications
Brand Name :
J-ENERGIZE
Model Number :
JET-AG110B12
Place of Origin :
XIAN, CHINA
MOQ :
1 Unit
Payment Terms :
L/C, T/T, negotiable
Delivery Time :
negotiable
Packaging Details :
Carton, Wooden Case.
Discharge current working range :
2~120A
Constant current discharge voltage range :
90~135V
Pack voltage range :
0~135V
Voltage testing accuracy :
0.5%
Battery capacity range :
20~1200Ah
Screen :
5.7-inch
Weight :
19 KGS
Product name :
Battery Load Tester,Battery Discharge Tester,DC Load Bank
Cell voltage range :
2V/6V/12V
Application :
oil,railway,electric power,telecommunications,Financial
Description

JET-AG 110B12 Load Bank

Stationary Batteries Constant Current Load 110 VDC 0-120 Amp Battery Discharger

Constant Current DC Load Bank 110 VDC 0-120 Amp

The only way to know if your stationary batteries will perform to specification is to test them regularly.

NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5 )years and VRLA batteries every 12–18 months.

JET-AG constant current load banks are an easy and affordable way to perform accurate IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests.

These units are quick and easy to set up. They display the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test.

These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge.

Key Functions

  • On-line monitoring function

When the battery pack is under the state of online discharge, uniform charge or floating charge, it performs real-time online monitoring for all cells. The monitoring items include pack voltage, cell voltage, pack charge/discharge current, pack charge/discharge capacity, pack monitoring time, and etc.

It can also monitor the temperature and to better known the state of each cell. (optional function)

  • Discharge function:

The battery pack is removed from system. It performs constant current discharge after setup the parameters. It shows real-time data, such as discharge current, discharge time, discharge capacity, pack voltage, cell voltage, and etc. Discharging can be stopped by the set parameters or artificially.

Key Features:

-- Supports real-time monitoring

-- 5.7 inch LCD touchscreen for easy operation and display of various parameters in real-time.

-- Full protection to protect machine and battery.

-- Supplied in a strong and mobile flightcase that can easily be taken everywhere.

-- Automatic stop discharge protection function is perfect, discharge time to; set the total voltage limit to; load line abnormal; stop the discharge automatically and alarm.

-- Saves each test result automatically and protects data

-- It cannot be started if the voltage is inconsistent between battery pack/cell and load bank.

-- When it is abnormal, it stops testing automatically to protecting batteries.

-- PC software included for detailed analysis of test results and generation of reports.

Specification

Model JET-AG 48B15 JET-AG 48B30 JET-AG 110B04(08/12) JET-AG 220B04(08/12) JET-AG 380B05 JET-AG 600B03
Cell voltage type 2V/6V/12V
Cell voltage range 2V: 0~4V; 6V: 0~8V; 12V: 0~16V
Cell voltage resolution 2V/6V: 0.001V; 12V: 0.01V
Pack voltage range 0~60V 0~60V 0~135V 0~270V 0~450V 0~600V
Pack voltage resolution 0.01V
Voltage testing accuracy 0.5%
Discharge current working range 2~150A 2~300A 2~40A(80A/120A) 2~40A(80A/120A) 2~50A 2~30A
Constant current discharge voltage range 42~60V 42~60V 90~135V 180~270V 340~450V 300~600V
Current resolution 0.1A
Current testing accuracy 1%
Battery capacity range 20~1500Ah 20~3000Ah 20~400Ah(800/1200Ah) 20~400Ah(800/1200Ah) 20~500Ah 20~800Ah
Cell voltage collection method wire
Working voltage AC220±15%
Cooling mode Refrigeration by blast
Environment Worked at 0℃~40℃, 20%~80%RH; Stored at -20℃~70℃
Comm interface RS232, USB
Display 5.7-inch touch color TFT screen
Dimensions (mm) 425*243*343 459*248*441

425*243*343

459*248*441

600*288*451

425*243*343

459*248*441

600*288*451

540*276*543 520*263*562
Weight (Kg) 13 17 13,17,19 13,17,19 22 22

Service

1, Support imprint your logo on products and let your logo shine anywhere

2, OEM/ODM orders available if quantity appropriate

3, We own the best after-sale service. If any problem happens, our team will do our best to solve it.

4, We can ship products by sea, by air and by Courier

Packaging and Delivery

1, Aluminum box and carton box, careful and tight package, make sure the package is intact during delivery.

2, The package will be shipped by DHL/FedEx/TNT/EMS/UPS/Special line, which can be specified in the order.

3, The shipping time is different, it depends on the distance between us, and the quantity ordered.

Send your message to this supplier
Send Now

Stationary DC Battery Load Tester Constant Current Load 110 VDC 0 - 120 Amp Battery Discharger

Ask Latest Price
Brand Name :
J-ENERGIZE
Model Number :
JET-AG110B12
Place of Origin :
XIAN, CHINA
MOQ :
1 Unit
Payment Terms :
L/C, T/T, negotiable
Delivery Time :
negotiable
Contact Supplier
Stationary DC Battery Load Tester Constant Current Load 110 VDC 0 - 120 Amp Battery Discharger

Xian Junbiao Electronics Technology Co.,Ltd.

Active Member
6 Years
Shaanxi
Since 2013
Business Type :
Manufacturer, Exporter
Certification Level :
Active Member
Contact Supplier
Submit Requirement