Lithium Cylindrical Battery Pack Sorter Selector Automatic Separation Grading Sorting Machine FOR 18650/26650/32650
Product Description
The XW series Li-ion battery automatic testing and formation system is the latest model of our company. developed this product on year 2002.The product apply for Li-ion battery formation, classification and performance parameters inspection etc. This product is a master-slave mode rechargeable battery complex testing system which consist by the micro computer and the micro processor, with advanced instruction, stable performance,easy to use, with high performance cost ratio, it is the
essential manufacturing testing system of the Li-ion battery manufacturer, subscriber, scientific rearch department.
Configuration and material of complete sets of equipment:
1. XW series li-ion battery automatic testing and formation system 1 sets
2. Communication wire 1pcs
3. Power Line 1 pcs
4. Spare Part( details check spare part list) 1 set
5. Information File 1 pcs
The items inside the information file:
1. Software installation disk 1 pcs
2. Product qualification 1 pcs
3. Product quality tracking card 1pcs
4. Warranty card 1pcs
5. Spare part list 1 pcs
6. User guide 1 pcs
7. Drawing 1 set
Product Specification
Channel voltage and current | 5V/3A | |||
Channel number | 512 Channnels | |||
Parallel unit number per channel | 1 | |||
Input AC type | 3 phase AC380V ±10%/50Hz | |||
Maximum input power | 14KW | |||
Noise | ≤65dB | |||
AC power supply wiring mode | Three-phase five wire connection | |||
The power factor of power supply | ≥0.99(The load power is more than 30% of rated power) | |||
Total current distortion rate | THD≤5% | |||
Conversion efficiency | Each link conversion efficiency is more than 85% | |||
Constant voltage setting range | Charging:0.02V~5V | |||
Minimum discharge voltage | Discharging:1V~5V | |||
Measuring range | 0V~5V | |||
The voltage resolution | 0.1mV | |||
Accuracy of control | ±(0.05%RD+0.05%FS) | |||
Accuracy of measurement | ±(0.05%RD+0.05%FS) | |||
Charging current setting range | 0.02A~3A | |||
Discharging current setting range | 0.02A~3A | |||
Measuring range | 0A~3A | |||
The current resolution | 16 Bit AD,DA | |||
Accuracy of control | ±(0.05%RD+0.05%FS) | |||
Accuracy of measurement | ±(0.05%RD+0.05%FS) | |||
Temperature drift | 25PPM/℃ | |||
Power | Single channel maximum output power | 30W | ||
Channel sampling time | 0.1s | |||
Current response time | The maximum current rise time 20ms | |||
Steps setting time range | 1min~1024min | |||
Time accuracy | ±0.01% |
XWELL factory