Neware 5V6A Battery Cell Reliability Test System Battery Recovery Tester
1 . To meet the various requirements adopted in advanced battery research , our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy , and can be fitted with additional hardware to provide a number of optional features and capabilities .
2 . 5V6A Battery Testing System is mainly used for testing polymer batteries , cylindrical batteries and super capacitors . The test of polymer batteries and super capacitors need Neware special accessories . Cylindrical batteries need to be clamped between the upper and down clamps of the equipment . By moving the position of the upper accessory accurately according to the scales on both sides , you can test different capacities of Cylinders Batteries .
3 . Neware 5V6A is powerful , reliable , it works on the very popular coin cell , cylindrical cell and prismatic cells , etc . It can be used for battery formation and grading , cycle - life test , performance and so on . From year 2016 , dual range 5V6A was successfully replaced the traditional 5V6A model . Higher range 100mA - 3A - 6A , makes it the best choice for cycle - life test and C - Rate test on 3C battery cells . Lower range 0.5mA - 100mA - 1A , makes 5V6A great for small pouch , coin cell and small battery test .
4 . Neware 5V6A is the most popular battery tester ever , more than 50 percent customers would choose this model as their main products . For customers who came across Neware the first time , 5V6A is also strongly suggested as their tryout demo machine .
Voltage | Per Channel Voltage Range | 1.5V - 5V |
Discharge Min Voltage | 1.5V | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers |