Neware 18650 Battery Rate Charge Discharge Capacity DCIR Tester
20ms Response Time
1 . This fast response time will meet rapidly changing power requirements
2 . Flexible Integration of Hardware and Data Management
3 . BTS 4000 functions also as the core part of auto formation and grading system .
4 . With its structural data system , testing data can be analysed , summarized , managed and utilized by our extended program or customers own data and logic server .
Accurate Timing
5 . Most of us are considering the voltage and current accuracies are the all important factors of a battery tester , but actually timing accuracy is of the same importance .
6 . Capacity or energy is calculated on time basis with the voltage and current measured , thus the timing accuracy will greatly affect the capacity calculated . To a general constant current or other constant testing regimes , this effect may not that easy to be observed .
7 . Left is from Neware , right is from another supplier in the marke .
Data Security
8 . Neware battery testing system utilizes LAN as the main framework to transfer data .
9 . This provides the most flexibility and reliablity to your system deployment .
10 . When you look down into Neware batter, its unique Middle Machine architecture provides another enhancement layer to the data security issue .
11 . Moreover, this MM is an embedded system that allows you run tests even your LAN is down.
12 . As we go deeper, dual embedded systems will have large redundancy to handle controls and data transfer.
Input Resistance | More than 1MΩ | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 25mV - 5V |
Discharge Min Voltage | 2.5V | |
Accuracy | 0.05percent of FS | |
Stability | 0.05percent of FS | |
Current | Per Channel Current Range | 0.1A - 20A |
Accuracy | 0.05percent of FS | |
Stability | 0.05percent of FS | |
Power | Per Channel Output Power | 100W |
Stability | 0.1 percent of FS | |
Charge | Charge Mode | Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , CPC |
End Conditon | Voltage , Current , Relative Time , Capacity | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition , Setting Parameter - Low Voltage limit / Upper Voltage limit / Low Current limit / Upper Current limit / Delay Time | ||
Hardware Protection | Additional Anti - reverse Protection Model | |
Voltage and Current Testing Sample | 4 - wire connecting | |
Noise | less than 85dB | |
Communication Interface | Ethernet Port | |
Per Unit Main Channels Number | 8 | |
Dimensions | 3U3F , 480 - 730 - 130mm |